Clinical Diagnostic Value of Shear-Wave Elastography in Detecting Malignant Nipple Retraction

被引:0
|
作者
Tan, Rong [1 ]
Liu, Jie [2 ]
Tang, Qi [1 ]
Chen, Hui [3 ]
Zhang, Zhenhui [4 ]
机构
[1] Cent South Univ, Affiliated Changsha Hosp, Dept Ultrasonog, Xiangya Sch Med,Hosp Changsha 1, Changsha, Hunan, Peoples R China
[2] Hunan Prov Maternal & Child Hlth Care Hosp, Dept Med Record & Stat Anal, Changsha, Hunan, Peoples R China
[3] Cent South Univ, Affiliated Changsha Hosp, Hosp Changsha 1, Dept Pathol,Xiangya Sch Med, Changsha, Hunan, Peoples R China
[4] Cent South Univ, Affiliated Changsha Hosp, Hosp Changsha 1, Dept Obstet,Xiangya Sch Med, 311 Yingpan Rd, Changsha 410005, Hunan, Peoples R China
关键词
nipple retraction; ultrasonography; shear-wave elastography; BREAST-CANCER; ULTRASOUND; BENIGN;
D O I
10.1097/RCT.0000000000001653
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesIn recent years, the use of shear-wave elastography (SWE) as a diagnostic tool for detecting malignant breast lesions has shown promising results. This study aims to determine the clinical diagnostic value of SWE in detecting malignant nipple retraction.MethodsBoth US and SWE (Philips EPIQ7 system) were performed for 41 consecutive patients with nipple retraction (56 nipples). The mean, median, and maximum tissue elasticity values (in kilopascals) were determined for each nipple by using SWE. The sensitivity, specificity, and overall accuracy of each measurement was determined by using the surgical pathology results or clinical diagnosis as the gold standard.ResultsOf the 56 retracted nipples, 32 were due to benign lesions, and 24 were due to malignant lesions. No significant differences in dimensions or echo features were found between the benign and malignant groups. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the color Doppler flow imaging (CDFI) pattern were 63.89% (23/36), 95% (19/20), 95.83 (23/24), 59.38 (19/32), and 75% (42/56), respectively; the corresponding values for median elasticity on SWE were 88.46% (23/26), 96.67% (29/30), 95.83 (23/24), 90.63 (29/32), and 92.85 (52/56), respectively.ConclusionsThe addition of SWE to conventional US could help differentiate benign from malignant lesions associated with nipple retraction.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 50 条
  • [41] Diagnostic performances of shear-wave elastography and B-mode ultrasound to differentiate benign and malignant breast lesions: the emphasis on the cutoff value of qualitative and quantitative parameters
    Song, Eun Jee
    Sohn, Yu-Mee
    Seo, Mirinae
    CLINICAL IMAGING, 2018, 50 : 302 - 307
  • [42] Shear-Wave Elastography of the Breast: Impact of Technical Image Quality Parameters on Diagnostic Accuracy
    Chou, Shinn-Huey S.
    Baikpour, Masoud
    Zhang, Wei
    Mercaldo, Sarah F.
    Lehman, Constance D.
    Samir, Anthony E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 216 (05) : 1205 - 1215
  • [43] Association of shear-wave elastography with clinical outcomes post-liver transplantation
    Boeken, Tom
    Lucidarme, Olivier
    Mbarki, Elsa
    Scatton, Olivier
    Savier, Eric
    Wagner, Mathilde
    CLINICS AND RESEARCH IN HEPATOLOGY AND GASTROENTEROLOGY, 2021, 45 (05)
  • [44] Value of Shear Wave Elastography for the Differentiation of Benign and Malignant Microcalcifications of the Breast
    Chamming's, Foucauld
    Mesurolle, Benoit
    Antonescu, Raluca
    Aldis, Ann
    Kao, Ellen
    Theriault, Melanie
    Omeroglu, Atilla
    Pinel-Giroux, Fanny
    Seidler, Matthew
    Solorzano, Silma
    Reinhold, Caroline
    Gallix, Benoit
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (02) : W85 - W92
  • [45] Value of Shear Wave Elastography for differentiating benign and malignant renal lesions
    Aydin, Sinem
    Yildiz, Seyma
    Turkmen, Ihsan
    Sharifov, Rasul
    Uysal, Omer
    Gucin, Zuhal
    Armagan, Abdullah
    Kocakoc, Ercan
    MEDICAL ULTRASONOGRAPHY, 2018, 20 (01) : 21 - 26
  • [46] Value of conventional ultrasound and shear-wave elastography in the assessment of mesenteric lymphadenitis in a paediatric population
    Zhou, Li
    Shan, Jun
    Zu, Dao-Ming
    Deng, Shu-Hao
    Zhang, Yuan
    Shi, Xiu-Rong
    Zhu, Yi-Cheng
    Jiang, Quan
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2024, 27 (06)
  • [47] Role of Strain Elastography and Shear-Wave Elastography in a Multiparametric Clinical Approach to Indeterminate Cytology Thyroid Nodules
    Gay, Stefano
    Schiaffino, Simone
    Santamorena, Graziana
    Massa, Barbara
    Ansaldo, Gianluca
    Turtulici, Giovanni
    Giusti, Massimo
    MEDICAL SCIENCE MONITOR, 2018, 24 : 6273 - 6279
  • [48] Shear-wave elastography in breast ultrasonography: the state of the art
    Youk, Ji Hyun
    Gweon, Hye Mi
    Son, Eun Ju
    ULTRASONOGRAPHY, 2017, 36 (04) : 300 - 309
  • [49] Shear-Wave Sources for Soft Tissues in Ultrasound Elastography
    Giammarinaro, B.
    Zorgani, A.
    Catheline, S.
    IRBM, 2018, 39 (04) : 236 - 242
  • [50] Shear-wave elastography of the liver in a healthy pediatric population
    Yang, Hanning
    Sun, Yue
    Tang, Yueyue
    Lu, Yongping
    Hu, Bing
    Ying, Tao
    JOURNAL OF CLINICAL ULTRASOUND, 2020, 48 (03) : 139 - 144