Clinical Diagnostic Value of Shear-Wave Elastography in Detecting Malignant Nipple Retraction

被引:0
|
作者
Tan, Rong [1 ]
Liu, Jie [2 ]
Tang, Qi [1 ]
Chen, Hui [3 ]
Zhang, Zhenhui [4 ]
机构
[1] Cent South Univ, Affiliated Changsha Hosp, Dept Ultrasonog, Xiangya Sch Med,Hosp Changsha 1, Changsha, Hunan, Peoples R China
[2] Hunan Prov Maternal & Child Hlth Care Hosp, Dept Med Record & Stat Anal, Changsha, Hunan, Peoples R China
[3] Cent South Univ, Affiliated Changsha Hosp, Hosp Changsha 1, Dept Pathol,Xiangya Sch Med, Changsha, Hunan, Peoples R China
[4] Cent South Univ, Affiliated Changsha Hosp, Hosp Changsha 1, Dept Obstet,Xiangya Sch Med, 311 Yingpan Rd, Changsha 410005, Hunan, Peoples R China
关键词
nipple retraction; ultrasonography; shear-wave elastography; BREAST-CANCER; ULTRASOUND; BENIGN;
D O I
10.1097/RCT.0000000000001653
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesIn recent years, the use of shear-wave elastography (SWE) as a diagnostic tool for detecting malignant breast lesions has shown promising results. This study aims to determine the clinical diagnostic value of SWE in detecting malignant nipple retraction.MethodsBoth US and SWE (Philips EPIQ7 system) were performed for 41 consecutive patients with nipple retraction (56 nipples). The mean, median, and maximum tissue elasticity values (in kilopascals) were determined for each nipple by using SWE. The sensitivity, specificity, and overall accuracy of each measurement was determined by using the surgical pathology results or clinical diagnosis as the gold standard.ResultsOf the 56 retracted nipples, 32 were due to benign lesions, and 24 were due to malignant lesions. No significant differences in dimensions or echo features were found between the benign and malignant groups. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the color Doppler flow imaging (CDFI) pattern were 63.89% (23/36), 95% (19/20), 95.83 (23/24), 59.38 (19/32), and 75% (42/56), respectively; the corresponding values for median elasticity on SWE were 88.46% (23/26), 96.67% (29/30), 95.83 (23/24), 90.63 (29/32), and 92.85 (52/56), respectively.ConclusionsThe addition of SWE to conventional US could help differentiate benign from malignant lesions associated with nipple retraction.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 50 条
  • [31] Shear-Wave Elastography of Segmental Infarction of the Testis
    Kantarci, Fatih
    Olgun, Deniz Cebi
    Mihmanli, Ismail
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (06) : 820 - 822
  • [32] Shear-Wave Elastography in the Characterization of Pleural Effusions
    Ozgokce, Mesut
    Durmaz, Fatma
    Yavuz, Alpaslan
    Urley, Ibrahim
    Yildiz, Hanifi
    Arslan, Harun
    Dundar, Ilyas
    Havan, Nuri
    Ogul, Havri
    ULTRASOUND QUARTERLY, 2019, 35 (02) : 164 - 168
  • [33] THE UTILITY OF SHEAR-WAVE ELASTOGRAPHY IN THE EVALUATION OF MYOSITIS
    Kolb, Manuel
    Ekert, Kaspar
    Schneider, Luisa
    Fritz, Jan
    Ioanoviciu, Sorin Dumitru
    Henes, Joerg
    Horger, Marius
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (08): : 2176 - 2185
  • [34] Limitations and artifacts in shear-wave elastography of the liver
    Bruce M.
    Kolokythas O.
    Ferraioli G.
    Filice C.
    O’Donnell M.
    Biomedical Engineering Letters, 2017, 7 (2) : 81 - 89
  • [35] REGULARIZED TRACKING OF SHEAR-WAVE IN ULTRASOUND ELASTOGRAPHY
    Horeh, Mahmoud Derakhshan
    Asif, Amir
    Rivaz, Hassan
    2017 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2017, : 6264 - 6268
  • [36] Stiffness of benign and malignant prostate tissue measured by shear-wave elastography: a preliminary study
    Rouviere, Olivier
    Melodelima, Christelle
    Au Hoang Dinh
    Bratan, Flavie
    Pagnoux, Gaele
    Sanzalone, Thomas
    Crouzet, Sebastien
    Colombel, Marc
    Mege-Lechevallier, Florence
    Souchon, Remi
    EUROPEAN RADIOLOGY, 2017, 27 (05) : 1858 - 1866
  • [37] Stiffness of benign and malignant prostate tissue measured by shear-wave elastography: a preliminary study
    Olivier Rouvière
    Christelle Melodelima
    Au Hoang Dinh
    Flavie Bratan
    Gaele Pagnoux
    Thomas Sanzalone
    Sébastien Crouzet
    Marc Colombel
    Florence Mège-Lechevallier
    Rémi Souchon
    European Radiology, 2017, 27 : 1858 - 1866
  • [38] Comparison of Shear-Wave and Strain Ultrasound Elastography in the Differentiation of Benign and Malignant Breast Lesions
    Chang, Jung Min
    Won, Jae-Kyung
    Lee, Kyoung-Bun
    Park, In Ae
    Yi, Ann
    Moon, Woo Kyung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (02) : W347 - W356
  • [39] Ultrasound elastography: compression elastography and shear-wave elastography in the assessment of tendon injury
    Rui Prado-Costa
    João Rebelo
    João Monteiro-Barroso
    Ana Sofia Preto
    Insights into Imaging, 2018, 9 : 791 - 814
  • [40] Ultrasound elastography: compression elastography and shear-wave elastography in the assessment of tendon injury
    Prado-Costa, Rui
    Rebelo, Joao
    Monteiro-Barroso, Joao
    Preto, Ana Sofia
    INSIGHTS INTO IMAGING, 2018, 9 (05): : 791 - 814