Development of post porcelain insulator for 1000 kV UHV AC

被引:0
|
作者
Zhang, Qin [1 ]
Wang, Shao-Wu [2 ]
Wu, Guang-Ya [1 ]
Ye, Li-Mao [3 ]
Zhang, Rui [1 ]
机构
[1] State Grid Electric Power Research Institute, Wuhan 430074, China
[2] State Grid Corporation of China, Beijing 100005, China
[3] Fushun Electric Porcelain Manufacturing Co., Ltd, Fushun 113006, China
来源
关键词
Porcelain - Seismic design - Earthquakes;
D O I
暂无
中图分类号
学科分类号
摘要
According to the requirements proposed by 1000 kV UHV AC demonstration project from southeastern Shanxi province to Jingmen in Hubei province, including the mechanical, electrical and seismic-resistant properties of post porcelain insulator, a pollution withstand voltage method was used to design the polluted external insulation of post porcelain insulator, and the calculation analysis of earthquake-resistant and the performance evaluation of anti-seismic were also carried out. Post porcelain insulator for 1000 kV UHV AC has been developed successfully by Fushun Electric Porcelain Manufacturing Co., Ltd., whose structural height is 10 m, rated bending failing load is 16 kN, torsion failing load is 10 kN · m, and creepage distance is 30250 mm. This insulator is composed of five single elements, and has excellent mechanical, pollution withstand voltage and earthquake-resistant properties, so it can be used in the area where pollution class is c. The simulations and service experience show that the mechanical and electrical properties of post porcelain insulator can satisfy the requirements proposed by 1000 kV UHV AC demonstration project from southeastern Shanxi province to Jingmen in Hubei province.
引用
收藏
页码:1437 / 1441
相关论文
共 50 条
  • [41] Voltage and Electric Field Distribution along Porcelain Long Rod Insulator String in AC 500kV Transmission Line
    Zhang, Baiqing
    Cui, Yandong
    Zhang, Wei
    Liu, Siyi
    Zheng, Qiuwei
    Yang, Shuai
    Gao, Song
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [42] Statistical Switching Overvoltages of 1200 kV UHV AC Transmission Line
    Annadi R.R.
    Patsa C.S.
    Journal of The Institution of Engineers (India): Series B, 2022, 103 (01) : 189 - 195
  • [43] Study on Parameters Design and Corona Characteristics Test Equivalent of Grading Rings for 1000kV UHV AC Compact Transmission Line
    Huang, Daochun
    Zheng, Zheng
    Huang, Zhengfang
    Xie, Xiongjie
    Ruan, Jiangjun
    Huo, Feng
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 638 - 642
  • [44] The Experimental Research of Secondary Arc in 1000kV UHV Systems in China
    He, Yanmiao
    Li, Wei
    Yang, Kun
    Cui, Boyuan
    Zhang, Pengfei
    Cao, Rongjiang
    Lin, Jiming
    Yuan, Yichao
    2015 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2015, : 161 - 165
  • [45] DC Bias Simulation of 1000 kV UHV Transformer Based on MATLAB/Simulink
    Hu Peng
    Yu Yongjun
    Wu Weili
    Sun Fan
    Qi xiaoxiao
    Liu Yong
    4TH INTERNATIONAL CONFERENCE ON MECHANICS AND MECHATRONICS RESEARCH (ICMMR 2017), 2017, 224
  • [46] Corona characteristic of power equipments used in ±1000 kV UHV DC system
    China Electric Power Research Institute, Beijing 100192, China
    不详
    不详
    Gaodianya Jishu, 2012, 12 (3182-3188):
  • [47] Key technologies of 1000 kV AC compact transmission
    Hu, Yi
    Wan, Bao-Quan
    He, Hui-Wen
    Gaodianya Jishu/High Voltage Engineering, 2011, 37 (08): : 1825 - 1831
  • [48] 日本1000kV UHV输电线路施工
    栾云
    电力建设, 1989, (06) : 72 - 72
  • [49] Study on the lightning protection of shielding failure for 1000 kV UHV transmission lines
    Wuhan High Voltage Research Institute of SGCC, Wuhan 430074, China
    Gaodianya Jishu, 2006, 12 (52-54):
  • [50] Analysis of GIC Reactive Power Response of 1000kV UHV Transformer
    Liu L.
    Zhang T.
    Zhang S.
    Wang Z.
    Dianwang Jishu/Power System Technology, 2019, 43 (05): : 1593 - 1598