Development of post porcelain insulator for 1000 kV UHV AC

被引:0
|
作者
Zhang, Qin [1 ]
Wang, Shao-Wu [2 ]
Wu, Guang-Ya [1 ]
Ye, Li-Mao [3 ]
Zhang, Rui [1 ]
机构
[1] State Grid Electric Power Research Institute, Wuhan 430074, China
[2] State Grid Corporation of China, Beijing 100005, China
[3] Fushun Electric Porcelain Manufacturing Co., Ltd, Fushun 113006, China
来源
关键词
Porcelain - Seismic design - Earthquakes;
D O I
暂无
中图分类号
学科分类号
摘要
According to the requirements proposed by 1000 kV UHV AC demonstration project from southeastern Shanxi province to Jingmen in Hubei province, including the mechanical, electrical and seismic-resistant properties of post porcelain insulator, a pollution withstand voltage method was used to design the polluted external insulation of post porcelain insulator, and the calculation analysis of earthquake-resistant and the performance evaluation of anti-seismic were also carried out. Post porcelain insulator for 1000 kV UHV AC has been developed successfully by Fushun Electric Porcelain Manufacturing Co., Ltd., whose structural height is 10 m, rated bending failing load is 16 kN, torsion failing load is 10 kN · m, and creepage distance is 30250 mm. This insulator is composed of five single elements, and has excellent mechanical, pollution withstand voltage and earthquake-resistant properties, so it can be used in the area where pollution class is c. The simulations and service experience show that the mechanical and electrical properties of post porcelain insulator can satisfy the requirements proposed by 1000 kV UHV AC demonstration project from southeastern Shanxi province to Jingmen in Hubei province.
引用
收藏
页码:1437 / 1441
相关论文
共 50 条
  • [1] Analysis on natural contamination characteristics of UHV AC post porcelain insulator
    Zhang, Rui
    Wu, Guangya
    Yuan, Tian
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [2] Electric Field Calculation and Grading Ring Optimization for 1000 kV AC Post Porcelain Insulator
    Du, Jinqiao
    Peng, Zongren
    Li, Jing
    Zhang, Shiling
    Li, Naiyi
    Fan, Chuanjie
    PROCEEDINGS OF THE 2013 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS (ICSD 2013), VOLS 1 AND 2, 2013, : 198 - 201
  • [3] Electromagnetic Environment of 1000kV UHV AC Substation
    Wan, Bao-Quan
    Xie, Hui-Chun
    Zhang, Guang-Zhou
    Zhang, Xiao-Wu
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 1413 - 1416
  • [4] Study on electromagnetic environment of ±800 kV UHV DC and 1000 kV UHV AC parallel transmission lines
    Wang, Guangzhou
    Yao, Degui
    Zhang, Songyang
    Wang, Donghui
    Wang, Leilei
    Guo, Xing
    Yang, Fan
    FOURTH INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2020, 467
  • [5] Design of grading rings for 1000 kV AC composite insulator
    Bian, Xing-Ming
    Zhang, Fu-Zeng
    Wang, Li-Ming
    Guan, Zhi-Cheng
    Wang, Lai
    Chen, Yong
    Bo, Xue-Wei
    Ren, Gui-Qing
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (05): : 980 - 986
  • [6] Research on 1000 kV AC insulator leakage current characteristic
    Zhang, Ya-Ping
    Dai, Min
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (02): : 242 - 246
  • [7] Grading Ring Optimization for Tension Porcelain Insulator String on Double Circuit Tension Tower in 1000 kV AC Transmission Lines
    Yang, Xi
    Peng, Zongren
    Lia, Jintao
    2012 IEEE 10TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM), 2012,
  • [8] Analysis and Verification of Strength of 110kV Porcelain Post Insulator
    Jin, Songan
    Mo, Wenxiong
    Wei, Jingrong
    Lu, Guojun
    Li, Xiyu
    Wang, Yong
    Liu, Chaofeng
    Min, Chao
    Dang, Zhenping
    Wang, Le
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT-SWITCHING TECHNOLOGY (ICEPE-ST), 2017, : 1010 - 1014
  • [9] Bundle conductor minimum ground clearance of 1000 kV AC UHV transmission lines
    Niu, Lin
    Du, Zhigang
    Zhao, Jianguo
    Dianli Zidonghua Shebei / Electric Power Automation Equipment, 2008, 28 (01): : 17 - 22
  • [10] Measurement and Analysis on Electromagnetic Environment of 1000kV UHV AC Transmission Line
    Zhao, Luxing
    Lu, Jiayu
    Wu, Guifang
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,