Dose mapping of an irradiation chamber of a gamma cell unit using Fricke gel dosimeters and Monte Carlo simulation

被引:0
|
作者
Edalatkhah, Elham [1 ]
Badiei, Shahryar [1 ]
机构
[1] Nucl Sci & Technol Res Inst, Radiat Applicat Res Sch, Tehran, Iran
关键词
Radiation processing; Gamma cell unit; Monte Carlo simulation; Fricke gel dosimeters; MCNP CODE; VERIFICATION; FACILITY; GEANT4; FILMS; TOOL;
D O I
10.1016/j.apradiso.2024.111631
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A gamma cell unit is used for gamma irradiation of small volume samples. Due to the sample volume, there is a dose distribution, which is imperative to be known for appropriate irradiation. In this study, samples of agarose Fricke gel dosimeters were prepared for the dose mapping of the gamma cell unit available in our laboratory. To place the dosimeters at precise locations within the irradiation chamber of the gamma cell unit, a specific phantom was designed and fabricated. In this way, the dose distribution was estimated using optical absorbance measurement of the gel dosimeters. For verification, isodose curves were also obtained using Monte Carlo simulations. The results indicate that the central east-west and north-south points in the irradiation chamber have the highest and lowest dose values, respectively. The experimental and simulation ratios of the dose uniformity was calculated to be 1.53 and 1.48, respectively. The accuracy of the dosimeter performance and the system's calibration quality are confirmed by the good agreement between the simulation and experimental results.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Gamma irradiation of cultural artifacts for disinfection using Monte Carlo simulations
    Choi, Jong-il
    Yoon, Minchul
    Kim, Dongho
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (11) : 2564 - 2568
  • [32] Dose rate determinations in the Portuguese Gamma Irradiation Facility: Monte Carlo simulations and measurements
    Oliveira, C
    Salgado, J
    de Carvalho, AF
    RADIATION PHYSICS AND CHEMISTRY, 2000, 58 (03) : 279 - 285
  • [33] Monte Carlo Simulation of the Dose Rate Distribution of a Moroccan Panoramic Gamma Irradiator Using the MCNPX Code
    Aknouch, A.
    Mouhib, M.
    Sebihi, R.
    Didi, A.
    El-ouardi, Y.
    Boubekraoui, A.
    Choukri, A.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2020, 75 (01) : 35 - 38
  • [34] Evaluating Backscattered Radiation into the Dose Monitor Chamber in the RefleXion X1 Using Monte Carlo Simulation
    Oderinde, O. M.
    Zaks, D.
    Huntzinger, C.
    Shirvani, S. M.
    Maniyedath, A.
    Laurence, T.
    Lu, M.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [35] Accelerating Monte Carlo Simulation for Radiotherapy Dose Calculation using a Massively Parallel Graphics Processing Unit
    Zhuge, Y.
    Xie, H.
    Miller, R. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S804 - S805
  • [36] Monte Carlo Simulation of the Dose Rate Distribution of a Moroccan Panoramic Gamma Irradiator Using the MCNPX Code
    A. Aknouch
    M. Mouhib
    R. Sebihi
    A. Didi
    Y. El-ouardi
    A. Boubekraoui
    A. Choukri
    Moscow University Physics Bulletin, 2020, 75 : 35 - 38
  • [37] Attenuation images of optical CT using Fricke xylenol orange gel for dose mapping in radiotherapy
    Tavares, P. V. S.
    Diniz, R. E.
    Rodrigues Jr, O.
    Campos, L. L.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 224
  • [38] Monte Carlo simulation of single-cell irradiation by an electron microbeam
    J. H. Miller
    M. Sowa Resat
    N. F. Metting
    K. Wei
    D. J. Lynch
    W. E. Wilson
    Radiation and Environmental Biophysics, 2000, 39 : 173 - 177
  • [39] Improving phytosanitary irradiation treatment of mangoes using Monte Carlo simulation
    Kim, Jongsoon
    Moreira, Rosana G.
    Castell-Perez, M. Elena
    JOURNAL OF FOOD ENGINEERING, 2015, 149 : 137 - 143
  • [40] EVALUATION OF GAMMA RADIATION DOSES IN SOIL USING THE MONTE CARLO SIMULATION
    Ionescu, Clement
    Sbirna, Liana Simona
    Mateescu, Monica Daniela
    Moldovan, Clementina Sabina
    Sbirna, Sebastian
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2012, 11 (07): : 1355 - 1360