Study on thermodynamic analysis and energy saving of heat integrated distillation column

被引:0
|
作者
Fang, Jing [1 ]
Diao, Mengyu [1 ]
Li, Chunli [1 ]
Xuan, Bihan [1 ]
机构
[1] School of Chemical Engineering, Hebei University of Technology, Tianjin,300130, China
关键词
Energy savings - Energy-consumption - Energy-savings - Entropy increase - Heat integrated distillation Column - Operating ranges - Thermal coupling - Thermo dynamic analysis - Thermodynamic efficiency - Thermodynamic energy;
D O I
10.16085/j.issn.1000-6613.2017-2594
中图分类号
学科分类号
摘要
In this study, a method of using entropy to analyze the reversibility of internal thermal coupling column was proposed. Taking the ethanol water system as an example, it was proved that the energy saving of the thermal coupling column was superior to the traditional column, and the optimum operating range of the column was determined. Based on the second law of thermodynamics, the thermodynamic efficiency and the entropy increase formula of the thermal coupled column were deduced. Firstly, it was proved theoretically that the thermal coupling column was superior to the traditional column in terms of energy saving, and it was also calculated separately by the experimental data. The results showed that the operable compression ratio of the column was initially reduced to 1.8-2.6 in order to achieve better heat transfer between two columns, and the energy consumption of the overhead column was the smallest when the compression ratio was at 2.2. However, the thermal efficiency of the whole column was the highest when the range of compression ratio was 2.2-2.5. When the compression ratio is 2.5, the entropy increase of the whole column was also better than the average of the entire operating range. Thus, it was considered that the thermal coupling column had higher reversibility and better energy saving effect in this range. Taking the energy consumption, thermodynamic efficiency and entropy increase and other parameters into account, the compression ratio of 2.2 to 2.5 was the best operating range of the column. © 2019, Chemical Industry Press. All right reserved.
引用
下载
收藏
页码:834 / 841
相关论文
共 50 条
  • [41] Nonlinear-wave based analysis and modeling of heat integrated distillation column
    Cong, Lin
    Chang, Liang
    Liu, Xinggao
    SEPARATION AND PURIFICATION TECHNOLOGY, 2015, 150 : 119 - 131
  • [42] Steady-state operation analysis of an ideal heat integrated distillation column
    Huang, KJ
    Qian, JX
    Zhan, DZ
    Masaru, N
    Takeichiro, T
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 1997, 5 (04) : 325 - 336
  • [43] Development on a coaxial heat integrated distillation column (HIDiC)
    Hideo Noda
    Takeichiro Takamatsu
    Kazumasa Aso
    Tosinari Nakanishi
    Kazufumi Yoshida
    Masaru Nakaiwa
    Tadahiro Mukaida
    Nobuyuki Kuratani
    Korean Journal of Chemical Engineering, 2000, 17 : 593 - 596
  • [44] Dynamics and control of heat integrated distillation column (HIDiC)
    Fukushima, Tomohiro
    Kano, Manabu
    Hasebe, Shinji
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2006, 39 (10) : 1096 - 1103
  • [45] STEADY-STATE OPERATION ANALYSIS OF AN IDEAL HEAT INTEGRATED DISTILLATION COLUMN
    黄克谨
    钱积新
    战德志
    中岩勝
    高松武一郎
    Chinese Journal of Chemical Engineering, 1997, (04) : 43 - 54
  • [46] Control strategy for the Super Heat Integrated Distillation Column
    Rodriguez, Manuel
    Diaz, Ismael
    28TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, 2018, 43 : 1257 - 1257
  • [47] Design and optimization of Heat Integrated Distillation Column "HIDiC"
    Yala, Omar
    Rouzineau, David
    Then-Hetreux, Raphacle
    Meyer, Michel
    27TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, PT B, 2017, 40B : 1783 - 1788
  • [48] Development on a coaxial heat integrated distillation column (HIDiC)
    Noda, H
    Takamatsu, T
    Aso, K
    Nakanishi, T
    Yoshida, K
    Nakaiwa, M
    Mukaida, T
    Kuratani, N
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2000, 17 (05) : 593 - 596
  • [49] Heat Transfer Study of Heat-Integrated Distillation Column (HIDiC) Using Simulation Techniques
    Pulido, Jeffrey Leon
    Martinez, Edgar Leonardo
    Wolf, Maria Regina
    Maciel Filho, Rubens
    IAENG TRANSACTIONS ON ENGINEERING TECHNOLOGIES, VOL 6, 2011, 1373
  • [50] Energy Saving Characteristics of an Internal Heat Integrated Reactive Distillation Process for Methyl Acetate Synthesis
    Yamaki, Takehiro
    Matsuda, Keigo
    Na-Ranong, Duangkamol
    Matsumoto, Hideyuki
    KAGAKU KOGAKU RONBUNSHU, 2016, 42 (02) : 56 - 59