Study on thermodynamic analysis and energy saving of heat integrated distillation column

被引:0
|
作者
Fang, Jing [1 ]
Diao, Mengyu [1 ]
Li, Chunli [1 ]
Xuan, Bihan [1 ]
机构
[1] School of Chemical Engineering, Hebei University of Technology, Tianjin,300130, China
关键词
Energy savings - Energy-consumption - Energy-savings - Entropy increase - Heat integrated distillation Column - Operating ranges - Thermal coupling - Thermo dynamic analysis - Thermodynamic efficiency - Thermodynamic energy;
D O I
10.16085/j.issn.1000-6613.2017-2594
中图分类号
学科分类号
摘要
In this study, a method of using entropy to analyze the reversibility of internal thermal coupling column was proposed. Taking the ethanol water system as an example, it was proved that the energy saving of the thermal coupling column was superior to the traditional column, and the optimum operating range of the column was determined. Based on the second law of thermodynamics, the thermodynamic efficiency and the entropy increase formula of the thermal coupled column were deduced. Firstly, it was proved theoretically that the thermal coupling column was superior to the traditional column in terms of energy saving, and it was also calculated separately by the experimental data. The results showed that the operable compression ratio of the column was initially reduced to 1.8-2.6 in order to achieve better heat transfer between two columns, and the energy consumption of the overhead column was the smallest when the compression ratio was at 2.2. However, the thermal efficiency of the whole column was the highest when the range of compression ratio was 2.2-2.5. When the compression ratio is 2.5, the entropy increase of the whole column was also better than the average of the entire operating range. Thus, it was considered that the thermal coupling column had higher reversibility and better energy saving effect in this range. Taking the energy consumption, thermodynamic efficiency and entropy increase and other parameters into account, the compression ratio of 2.2 to 2.5 was the best operating range of the column. © 2019, Chemical Industry Press. All right reserved.
引用
下载
收藏
页码:834 / 841
相关论文
共 50 条
  • [31] Heat Transfer Investigation and Modeling of Heat Integrated Distillation Column
    Fang Jing
    Wang Yijing
    Su Weiyi
    Xuan Bihan
    Li Chunli
    CHINA PETROLEUM PROCESSING & PETROCHEMICAL TECHNOLOGY, 2018, 20 (03) : 96 - 105
  • [32] Control configurations for an energy integrated distillation column
    Koggersbol, A
    Andersen, BR
    Nielsen, JS
    Jorgensen, SB
    COMPUTERS & CHEMICAL ENGINEERING, 1996, 20 : S853 - S858
  • [33] A new horizontal distillation for energy saving with a diabatic rectangular column
    Dae Jin Jang
    Young Han Kim
    Korean Journal of Chemical Engineering, 2015, 32 : 2181 - 2186
  • [35] Energy Saving through Control in an Industrial Multicomponent Distillation Column
    Porru, Marcella
    Baratti, Roberto
    Alvarez, Jesus
    IFAC PAPERSONLINE, 2015, 48 (08): : 1138 - 1143
  • [36] Sensitivity Analysis of an Energy-Efficient Heat Coupled Distillation Column
    Sun, Lanyi
    Li, Jun
    Liu, Xuenuan
    Li, Qingsong
    ADVANCED RESEARCH ON INFORMATION SCIENCE, AUTOMATION AND MATERIAL SYSTEM, PTS 1-6, 2011, 219-220 : 424 - 427
  • [37] A new horizontal distillation for energy saving with a diabatic rectangular column
    Jang, Dae Jin
    Kim, Young Han
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2015, 32 (11) : 2181 - 2186
  • [38] Verification of energy conservation for discretely heat integrated distillation column through commercial operation
    Wakabayashi, Toshihiro
    Yoshitani, Kazushi
    Takahashi, Hidekazu
    Hasebe, Shinji
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2019, 142 : 1 - 12
  • [39] Reversibility Analysis for Design Optimization of an Internally Heat-Integrated Distillation Column
    Xu, Lianghua
    Yuan, Xigang
    Chen, Dawei
    Luo, Yiqing
    Yu, Kuotsung
    CHEMICAL ENGINEERING & TECHNOLOGY, 2013, 36 (07) : 1147 - 1156
  • [40] RESILIENCE ANALYSIS OF HEAT-INTEGRATED DOUBLE-COLUMN DISTILLATION SYSTEMS
    GOEL, PK
    NAKANISHI, E
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1986, 19 (01) : 7 - 13