Revolutionizing electric vehicle cooling: Optimal performance of R1234yf two-phase refrigerant cooling for EV battery thermal management system

被引:0
|
作者
Dhamodharan, Palanisamy [1 ]
Salman, Mohammad [2 ,3 ]
Prabakaran, Rajendran [2 ]
Choi, Gyu Sang [1 ]
Kim, Sung Chul [2 ]
机构
[1] Yeungnam Univ, Sch Mech & IT Engn, Dept Informat & Commun Engn, 280 Daehak Ro, Gyongsan 712749, Gyeongbuk, South Korea
[2] Yeungnam Univ, Sch Mech Engn, 280 Daehak Ro, Gyongsan 712749, Gyeongbuk, South Korea
[3] Korea Inst Energy Res, Thermal Energy Convers Syst, Daejeon, South Korea
关键词
Battery thermal management system; R1234yf; Offset strip fin plate heat exchanger; Cooling performance parameters; Carbon footprint analysis; BOILING HEAT-TRANSFER; LITHIUM-ION BATTERIES; PRESSURE-DROP; TRANSFER COEFFICIENTS; GENERATION; R134A; EXCHANGERS; SIMULATION; R-134A; MODEL;
D O I
10.1016/j.applthermaleng.2024.125070
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigates the effectiveness of R1234yf-based two-phase refrigerant cooling (TRC) in a secondary heat exchanger (test evaporator) designed for battery thermal management systems (BTMS) in electric vehicles. A brazed plate heat exchanger with an offset strip fin configuration is employed to assess various performance metrics, including heat-transfer coefficient (HTC), frictional pressure drop (FPD), cooling performance index (CPI), and inner wall temperature (Tiw). Experiments are conducted across saturation temperatures (Tsat) ranging from 16 to 24 degrees C, mass flux values of 30 to 70 kg/m2s, and inlet vapor-quality levels from 0.1 to 0.8 for standard discharge rates (C-rates) of 1.25. Additional experiments at lower (30 kg/m2s) and higher mass flux (50 kg/m2s) are performed for discharge rates of 1-1.5C to identify optimal conditions. Results indicate that R1234yf exhibits superior cooling performance across all C-rates at 30 kg/m2s and 20 degrees C, with HTC increasing by 28 % for 1C and 26 % for 1.5C. The FPD decreases by 30.5 %, 26.4 %, and 21.9 %, leading to increases in the cooling performance index of 44 %, 33 %, and 24 % for 1C, 1.25C, and 1.5C, respectively. Lower mass flux (30 kg/m2s) yields reduced T iw at T sat of 20 degrees C across all discharge rates, with minimal T iw variations observed within specific xm ranges (0.57-0.67). A novel correlation is developed integrating a proposed battery and heat-transfer model, validated against experimental results with a 25 % error margin, suggesting further exploration in TRC-based BTMS. Additionally, carbon footprint analysis demonstrates the environmental superiority of R1234yf refrigerant, exhibiting a substantial Total Equivalent Warming Impact reduction of up to 4-28 % compared to conventional R134a refrigerant, affirming its eco-friendly nature and potential for utilization in TRC for battery cooling in BTMS.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Enhancing Li-Ion Electric Vehicle Battery Performance: Analysis of Advanced Thermal Management Cooling Strategies with Phase Change Material
    Dewangan, Ashish
    Shukla, Anuj Kumar
    ENERGY TECHNOLOGY, 2024,
  • [32] Numerical investigation on thermal performance of battery module with LCP-AFC cooling system applied in electric vehicle
    Guo, Huizhen
    Li, Juan
    Zhu, Zhangyu
    Lv, Peihong
    ENERGY SCIENCE & ENGINEERING, 2022, 10 (12) : 4431 - 4446
  • [33] Experimental investigation on thermal performance of a pumped two-phase battery cooling system using mini-channel cold plate
    Xu, Dan
    Fang, Yidong
    Hu, Lingren
    Yang, Wenliang
    Su, Lin
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (11) : 16078 - 16090
  • [34] Experimental assessment and comparison of single-phase versus two-phase liquid cooling battery thermal management systems
    Wu, Nan
    Chen, Yisheng
    Lin, Boshen
    Li, Junjie
    Zhou, Xuelong
    JOURNAL OF ENERGY STORAGE, 2023, 72
  • [35] Investigation on Cooling Performance of Composite PCM and Graphite Fin for Battery Thermal Management System of Electric Vehicles
    Mane, Nikhil S.
    Kodancha, Pradyumna
    Hemadri, Vadiraj
    Tripathi, Siddhartha
    ENERGY STORAGE, 2024, 6 (06)
  • [36] Performance Improvement of a Novel Trapezoid Air-Cooling Battery Thermal Management System for Electric Vehicles
    Zhao, Gang
    Wang, Xiaolin
    Negnevitsky, Michael
    Zhang, Hengyun
    Li, Chengjiang
    SUSTAINABILITY, 2022, 14 (09)
  • [37] Comparative study on the thermal performance of the battery two-phase direct CO2 cooling system with parallel and half-series configuration for electric vehicles
    Fang, Jianmin
    Yin, Xiang
    Guan, Jiajia
    Han, Xu
    Jia, Fan
    Chen, Bin
    Cao, Feng
    Wang, Xiaolin
    RENEWABLE ENERGY, 2025, 242
  • [38] Enhancing Thermal Performance and Cooling Solutions of Phase Change Material in Battery Thermal Management System: A Computational Analysis
    Singh, Gourav Kumar
    Patel, Jay R.
    Rathod, Manish K.
    ENERGY STORAGE, 2024, 6 (06)
  • [39] Shell-and-tube evaporator model performance with different two-phase flow heat transfer correlations. Experimental analysis using R134a and R1234yf
    Navarro-Esbri, Joaquin
    Moles, Francisco
    Peris, Bernardo
    Barragan-Cervera, Angel
    Manuel Mendoza-Miranda, Juan
    Mota-Babiloni, Adrian
    Manuel Belman, Juan
    APPLIED THERMAL ENGINEERING, 2014, 62 (01) : 80 - 89
  • [40] Multi-objective design optimization for mini-channel cooling battery thermal management system in an electric vehicle
    Li, Wei
    Peng, Xiongbin
    Xiao, Mi
    Garg, Akhil
    Gao, Liang
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (08) : 3668 - 3680