Revolutionizing electric vehicle cooling: Optimal performance of R1234yf two-phase refrigerant cooling for EV battery thermal management system

被引:0
|
作者
Dhamodharan, Palanisamy [1 ]
Salman, Mohammad [2 ,3 ]
Prabakaran, Rajendran [2 ]
Choi, Gyu Sang [1 ]
Kim, Sung Chul [2 ]
机构
[1] Yeungnam Univ, Sch Mech & IT Engn, Dept Informat & Commun Engn, 280 Daehak Ro, Gyongsan 712749, Gyeongbuk, South Korea
[2] Yeungnam Univ, Sch Mech Engn, 280 Daehak Ro, Gyongsan 712749, Gyeongbuk, South Korea
[3] Korea Inst Energy Res, Thermal Energy Convers Syst, Daejeon, South Korea
关键词
Battery thermal management system; R1234yf; Offset strip fin plate heat exchanger; Cooling performance parameters; Carbon footprint analysis; BOILING HEAT-TRANSFER; LITHIUM-ION BATTERIES; PRESSURE-DROP; TRANSFER COEFFICIENTS; GENERATION; R134A; EXCHANGERS; SIMULATION; R-134A; MODEL;
D O I
10.1016/j.applthermaleng.2024.125070
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study investigates the effectiveness of R1234yf-based two-phase refrigerant cooling (TRC) in a secondary heat exchanger (test evaporator) designed for battery thermal management systems (BTMS) in electric vehicles. A brazed plate heat exchanger with an offset strip fin configuration is employed to assess various performance metrics, including heat-transfer coefficient (HTC), frictional pressure drop (FPD), cooling performance index (CPI), and inner wall temperature (Tiw). Experiments are conducted across saturation temperatures (Tsat) ranging from 16 to 24 degrees C, mass flux values of 30 to 70 kg/m2s, and inlet vapor-quality levels from 0.1 to 0.8 for standard discharge rates (C-rates) of 1.25. Additional experiments at lower (30 kg/m2s) and higher mass flux (50 kg/m2s) are performed for discharge rates of 1-1.5C to identify optimal conditions. Results indicate that R1234yf exhibits superior cooling performance across all C-rates at 30 kg/m2s and 20 degrees C, with HTC increasing by 28 % for 1C and 26 % for 1.5C. The FPD decreases by 30.5 %, 26.4 %, and 21.9 %, leading to increases in the cooling performance index of 44 %, 33 %, and 24 % for 1C, 1.25C, and 1.5C, respectively. Lower mass flux (30 kg/m2s) yields reduced T iw at T sat of 20 degrees C across all discharge rates, with minimal T iw variations observed within specific xm ranges (0.57-0.67). A novel correlation is developed integrating a proposed battery and heat-transfer model, validated against experimental results with a 25 % error margin, suggesting further exploration in TRC-based BTMS. Additionally, carbon footprint analysis demonstrates the environmental superiority of R1234yf refrigerant, exhibiting a substantial Total Equivalent Warming Impact reduction of up to 4-28 % compared to conventional R134a refrigerant, affirming its eco-friendly nature and potential for utilization in TRC for battery cooling in BTMS.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Experimental Performance of a Completely Passive Thermosyphon Cooling System Rejecting Heat by Natural Convection Using the Working Fluids R1234ze, R1234yf, and R134a
    Cataldo, Filippo
    Thome, John Richard
    JOURNAL OF ELECTRONIC PACKAGING, 2018, 140 (02)
  • [22] Adaptive secondary loop liquid cooling with refrigerant cabin active thermal management system for electric vehicle
    Singirikonda, Srinivas
    Obulesu, Yeddula Pedda
    JOURNAL OF ENERGY STORAGE, 2022, 50
  • [23] Parametric Investigation on the Electrical-Thermal Performance of Battery Modules with a Pumped Two-Phase Cooling System
    Wang, Jun
    Ruan, Lin
    Li, Ruiwei
    ENERGIES, 2022, 15 (21)
  • [24] Research on Performance Optimization of Liquid Cooling and Composite Phase Change Material Coupling Cooling Thermal Management System for Vehicle Power Battery
    Wu, Gang
    Liu, Feng
    Li, Sijie
    Luo, Na
    Liu, Zhiqiang
    Li, Yuqaing
    JOURNAL OF RENEWABLE MATERIALS, 2023, 11 (02) : 707 - 730
  • [25] Review on refrigerant for direct-cooling thermal management system of lithium-ion battery for electric vehicles
    Yang S.
    Zhou S.
    Zhang Y.
    Hua Y.
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2019, 45 (11): : 2123 - 2132
  • [26] Simulation Study on Thermal Performance of an Indirect Boiling Cooling Cylindrical Battery System with Two-Phase Coolant R141b
    Tang, Zhiguo
    Ji, Yongtao
    Sun, Ran
    Cheng, Jianping
    ENERGY TECHNOLOGY, 2023, 11 (12)
  • [27] Design and analysis of electric vehicle thermal management system based on refrigerant-direct cooling and heating batteries
    Wang, Z. R.
    Huang, L. P.
    He, F.
    JOURNAL OF ENERGY STORAGE, 2022, 51
  • [28] Investigation on an integrated thermal management system with battery cooling and motor waste heat recovery for electric vehicle
    Tian, Zhen
    Gan, Wei
    Zhang, Xuelai
    Gu, Bo
    Yang, Lin
    APPLIED THERMAL ENGINEERING, 2018, 136 : 16 - 27
  • [29] Experimental study on thermal performance of a pumped two-phase battery thermal management system
    Zhu, Yue
    Fang, Yidong
    Su, Lin
    Fei, Ye
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (06) : 4664 - 4676
  • [30] Experimental studies on two-phase immersion liquid cooling for Li-ion battery thermal management
    Wang, Yuhang
    Li, Chaoen
    Wen, Xiaodong
    Cai, Wei
    Jiang, Yi
    Wen, Chenxiang
    Wang, Yuxiang
    Hu, Liangji
    Yu, Hang
    Zhu, Han
    Guo, Haijin
    Liu, Dongjing
    JOURNAL OF ENERGY STORAGE, 2023, 72