Design and analysis of a novel natural gas liquefaction process based on two-stage ejector-expansion refrigeration cycle

被引:0
|
作者
Pan, Jie [1 ,2 ]
Li, Yuanyuan [1 ]
Cao, Qinghan [1 ]
Wang, Jiale [3 ]
Li, Ran [1 ]
机构
[1] Xian Shiyou Univ, Coll Petr Engn, Xian 710065, Peoples R China
[2] Xian Shiyou Univ, Univ Shaanxi Prov, Engn Res Ctr Safety & Energy Saving Oil & Gas Stor, Xian 710065, Peoples R China
[3] Shaanxi Yanchang Petr Grp Co Ltd, Nat Gas Res Inst, Xian 710065, Peoples R China
关键词
Natural gas liquefaction; Ejector; Two-stage cycle refrigeration; Thermodynamic analysis; Thermo-economic analysis; ADVANCED EXERGOECONOMIC ANALYSIS; VAPOR COMPRESSION REFRIGERATION; CO2; RANKINE-CYCLE; LNG COLD ENERGY; MULTIOBJECTIVE OPTIMIZATION; ECONOMIC-ANALYSIS; THERMOECONOMIC OPTIMIZATION; ENVIRONMENTAL-ANALYSES; POWER CYCLE; SYSTEM;
D O I
10.1016/j.fuel.2024.134004
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes a novel natural gas liquefaction process based on two-stage ejector-expansion refrigeration cycle (T-EERC). Specific energy consumption, exergy efficiency, liquefaction ratio, and total cost rate indexes are applied to evaluate the process. Subsequently, energy, exergy, economic, exergoenvironmental, and exergoeconomic analysis are performed to the T-EERC process. The T-EERC process is capable of producing 47.21 kg/ s of liquefied natural gas (LNG), with a specific energy consumption of 0.2336 kWh/kg, an exergy efficiency of 57.95 %, a liquefaction ratio of 62.94 % and a total cost rate of 0.1562 M$/year, offers a better performance than other natural gas liquefaction processes. The system sensitivity analysis indicates that an increase in the high pressure inlet of the ejector leads to an increase in specific energy consumption for the system and a decrease in exergy efficiency. The energy analysis shows that the heat exchanger HX1 exhibits the lowest energy loss and the maximum heat transfer efficiency. From the exergy analysis, it is found that the total exergy destruction is 30867.43 kW and the greatest exergy destruction was associated with the heat exchangers, the throttles and the compressors. The economic analysis suggests that the total cost rate is more sensitive to fluctuations in the annual interest rate. The exergoenvironmental analysis indicates that the system operates at higher temperatures with less environmental impact. From an exergoeconomic perspective, the maximum cost rate of exergy destruction (720.95$/h) is related to HX5. Furthermore, the exergoeconomic factor of heat exchangers is typically minimal, necessitating supplementary financial outlay to enhance their performance.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Exergy analysis of multistage cascade refrigeration cycle used for natural gas liquefaction
    Kanoglu, M
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2002, 26 (08) : 763 - 774
  • [42] Performance analysis of a dual-ejector enhanced two-stage auto-cascade refrigeration cycle for ultra-low temperature refrigeration
    Shi, Rongxuan
    Bai, Tao
    Wan, Jiahao
    APPLIED THERMAL ENGINEERING, 2024, 240
  • [43] Thermodynamic analysis of two-stage and dual-temperature ejector refrigeration cycles driven by the waste heat of exhaust gas
    Liang, Youcai
    Ye, Kai
    Zhu, Yan
    Lu, Jidong
    ENERGY, 2023, 278
  • [44] Theoretical analysis of a double ejector-expansion autocascade refrigeration cycle using hydrocarbon mixture R290/R170
    Liu, Ye
    Yu, Jianlin
    Yan, Gang
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 94 : 33 - 39
  • [45] Design and optimization of large-scale natural gas liquefaction process based on triple refrigeration cycles
    Pu, Liming
    Xiong, Yingjie
    Wang, Ke
    Tang, Lin
    Qiu, Limin
    Wang, Kai
    ENERGY, 2024, 313
  • [46] Conceptual design and analysis of a novel process for BOG re-liquefaction combined with absorption refrigeration cycle
    Yin, Liang
    Ju, Yonglin
    ENERGY, 2020, 205
  • [47] Vortex Tube Expansion Two-stage Transcritical CO2 Refrigeration Cycle
    Liu, Yingfu
    Jin, Guangya
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 1219 - +
  • [48] Energy and Exergy Efficiency Analysis of an Ejector-Expansion Refrigeration Cycle Using the Working Fluid R134a and Its Potential Substitutes
    Liu, Xiaoqin
    Wang, Weibin
    Wang, Jianyong
    ENERGY SCIENCE & ENGINEERING, 2025,
  • [49] Exergy analysis of vapor compression refrigeration cycle with two-stage and intercooler
    Kilic, Bayram
    HEAT AND MASS TRANSFER, 2012, 48 (07) : 1207 - 1217
  • [50] Exergy analysis of vapor compression refrigeration cycle with two-stage and intercooler
    Bayram Kılıç