Design and analysis of a novel natural gas liquefaction process based on two-stage ejector-expansion refrigeration cycle

被引:0
|
作者
Pan, Jie [1 ,2 ]
Li, Yuanyuan [1 ]
Cao, Qinghan [1 ]
Wang, Jiale [3 ]
Li, Ran [1 ]
机构
[1] Xian Shiyou Univ, Coll Petr Engn, Xian 710065, Peoples R China
[2] Xian Shiyou Univ, Univ Shaanxi Prov, Engn Res Ctr Safety & Energy Saving Oil & Gas Stor, Xian 710065, Peoples R China
[3] Shaanxi Yanchang Petr Grp Co Ltd, Nat Gas Res Inst, Xian 710065, Peoples R China
关键词
Natural gas liquefaction; Ejector; Two-stage cycle refrigeration; Thermodynamic analysis; Thermo-economic analysis; ADVANCED EXERGOECONOMIC ANALYSIS; VAPOR COMPRESSION REFRIGERATION; CO2; RANKINE-CYCLE; LNG COLD ENERGY; MULTIOBJECTIVE OPTIMIZATION; ECONOMIC-ANALYSIS; THERMOECONOMIC OPTIMIZATION; ENVIRONMENTAL-ANALYSES; POWER CYCLE; SYSTEM;
D O I
10.1016/j.fuel.2024.134004
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes a novel natural gas liquefaction process based on two-stage ejector-expansion refrigeration cycle (T-EERC). Specific energy consumption, exergy efficiency, liquefaction ratio, and total cost rate indexes are applied to evaluate the process. Subsequently, energy, exergy, economic, exergoenvironmental, and exergoeconomic analysis are performed to the T-EERC process. The T-EERC process is capable of producing 47.21 kg/ s of liquefied natural gas (LNG), with a specific energy consumption of 0.2336 kWh/kg, an exergy efficiency of 57.95 %, a liquefaction ratio of 62.94 % and a total cost rate of 0.1562 M$/year, offers a better performance than other natural gas liquefaction processes. The system sensitivity analysis indicates that an increase in the high pressure inlet of the ejector leads to an increase in specific energy consumption for the system and a decrease in exergy efficiency. The energy analysis shows that the heat exchanger HX1 exhibits the lowest energy loss and the maximum heat transfer efficiency. From the exergy analysis, it is found that the total exergy destruction is 30867.43 kW and the greatest exergy destruction was associated with the heat exchangers, the throttles and the compressors. The economic analysis suggests that the total cost rate is more sensitive to fluctuations in the annual interest rate. The exergoenvironmental analysis indicates that the system operates at higher temperatures with less environmental impact. From an exergoeconomic perspective, the maximum cost rate of exergy destruction (720.95$/h) is related to HX5. Furthermore, the exergoeconomic factor of heat exchangers is typically minimal, necessitating supplementary financial outlay to enhance their performance.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Design and Optimization of Pressurized Liquefaction Processes for Offshore Natural Gas Using Two-Stage Cascade Refrigeration Cycles
    Lin, Wensheng
    Xiong, Xiaojun
    Spitoni, Marco
    Gu, Anzhong
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2018, 57 (17) : 5858 - 5867
  • [22] Theoretical study on a novel R32 refrigeration cycle with a two-stage suction ejector
    Yu, Jianlin
    Song, Xin
    Ma, Ming
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (01): : 166 - 172
  • [23] Thermoeconomic analysis of CO2 Ejector-Expansion Refrigeration Cycle (EERC) for low-temperature refrigeration in warm climates
    Peris Perez, Bernardo
    Exposito Carrillo, Jose Antonio
    Sanchez de La Flor, Francisco Jose
    Salmeron Lissen, Jose Manuel
    Morillo Navarro, Andres
    APPLIED THERMAL ENGINEERING, 2021, 188
  • [24] Energetic and Exergetic Analysis of an Ejector-Expansion Refrigeration Cycle Using the Working Fluid R32
    Zhang, Zhenying
    Tong, Lirui
    Chang, Li
    Chen, Yanhua
    Wang, Xingguo
    ENTROPY, 2015, 17 (07) : 4744 - 4761
  • [25] Performance analysis of a novel compressor-ejector cycle with two-stage evaporation
    Liang X.
    Liu H.
    Cao X.
    Shao L.
    Zhang C.
    Huagong Xuebao/CIESC Journal, 2018, 69 : 26 - 30
  • [26] Thermodynamic analysis of a modified two-stage transcritical CO2 refrigeration cycle with an ejector and a subcooler
    Li, Huanmin
    Huang, Qiuyue
    Yu, Jianlin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 168 : 492 - 505
  • [27] Theoretical analysis on a novel two-stage compression transcritical CO2 dual-evaporator refrigeration cycle with an ejector
    Liu, Ye
    Liu, Jiarui
    Yu, Jianlin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 119 : 268 - 275
  • [28] Optimal design of two-stage ejector for subzero refrigeration system on fishing vessel
    Wang, Xinli
    Wang, Lei
    Song, Yajie
    Deng, Jie
    Zhan, Youjie
    APPLIED THERMAL ENGINEERING, 2021, 187
  • [29] Performance analysis of a two-stage ejector in an ejector refrigeration system using computational fluid dynamics
    Suvarnakuta, N.
    Pianthong, K.
    Sriveerakul, T.
    Seehanam, W.
    ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2020, 14 (01) : 669 - 682
  • [30] Analysis of modified CO2 based combined power and ejector-expansion refrigeration cycle with dual evaporators activated by engine exhaust
    Zhu, Yan
    Liang, Youcai
    Liang, Yaling
    Kong, Bo
    Pan, Mingzhang
    Wang, Zongrun
    Deng, Haiying
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2023,