Continuous blood pressure monitoring based on transformer encoders and stacked attention gated recurrent units

被引:0
|
作者
机构
[1] [1,Huang, Zhiwen
[2] Shao, Jiajie
[3] Zhou, Panyu
[4] Liu, Baolin
[5] Zhu, Jianmin
[6] Fang, Dianjun
关键词
Cardiology - Disease control - Electrocardiography - Photoplethysmography;
D O I
10.1016/j.bspc.2024.106860
中图分类号
学科分类号
摘要
Continuous blood pressure monitoring (CBPM) is critical to support the accurate prevention and reliable treatment of cardiovascular diseases. To achieve efficient multi-information interaction and further improve the monitoring performance, this research proposes an intelligent model based on transformer encoders and stacked attention gated recurrent units (TE-SAGRU) for CBPM. Long-term multi-source feature sequences with rich information are initially extracted from photoplethysmography (PPG) and electrocardiography (ECG) signals. The paralleled transformer encoders are constructed for different source feature sequences to obtain high-level feature representations and preserve respective long-term independence. The multiple stacked attention gated recurrent units are cross-connected for multi-interactive feature fusion and promoting complementarity effects of multi-source features on CBPM. Comprehensive comparison experiments are carried out to validate the effectiveness of the TE-SAGRU model, using the dataset with 1000 subjects derived from the MIMIC-III database. The continuous monitoring errors of the TE-SAGRU model for systolic blood pressure (SBP) and diastolic blood pressure (DBP) are 3.91 ± 5.65 mmHg and 2.29 ± 3.01 mmHg. The monitored results pass the requirement of the Association for the Advancement of Medical Instrumentation (AAMI) standard and achieve Grade A of the British Hypertension Society (BHS) protocol. © 2024 Elsevier Ltd
引用
下载
收藏
相关论文
共 50 条
  • [31] A CMOS-based tactile sensor for continuous blood pressure monitoring
    Kirstein, KU
    Sedivy, J
    Salo, T
    Hagleitner, C
    Vancura, T
    Hierlemann, A
    DESIGNERS' FORUM: DESIGN, AUTOMATION AND TEST IN EUROPE CONFERENCE AND EXHIBITION, 2005, : 210 - 214
  • [32] Design and Research of Continuous Blood Pressure Monitoring System Based on LoRa
    Yan Zhe
    Hu Weiping
    2019 4TH INTERNATIONAL CONFERENCE ON COMMUNICATION AND INFORMATION SYSTEMS (ICCIS 2019), 2019, : 267 - 272
  • [33] A CMOS-based tactile sensor for continuous blood pressure monitoring
    Kirstein, KU
    Sedivy, J
    Salo, T
    Hagleitner, C
    Vancura, T
    Baltes, H
    ESSCIRC 2004: PROCEEDINGS OF THE 30TH EUROPEAN SOLID-STATE CIRCUITS CONFERENCE, 2004, : 463 - 466
  • [34] Continuous blood pressure monitoring based on pulse wave velocity method
    Yamada, Ichiro
    Transactions of Japanese Society for Medical and Biological Engineering, 2014, 52
  • [35] Optical-Based Sensor Prototype for Continuous Monitoring of the Blood Pressure
    Cohen, Zachary
    Haxha, Shyqyri
    IEEE SENSORS JOURNAL, 2017, 17 (13) : 4258 - 4268
  • [36] Wearable Smartwatch based on Optical Fiber for Continuous Blood Pressure Monitoring
    Li, Liangye
    Liu, Yunfei
    Sheng, Shunfeng
    Song, Changying
    Fan, Wei
    Sun, Qizhen
    2022 OPTICAL FIBER COMMUNICATIONS CONFERENCE AND EXHIBITION (OFC), 2022,
  • [37] Gated Recurrent Units Based Recurrent Neural Network for Forecasting the Characteristics of the Next Earthquake
    Gonzalez, Jesus
    Yu, Wen
    Telesca, Luciano
    CYBERNETICS AND SYSTEMS, 2022, 53 (02) : 209 - 222
  • [38] Inversion Method for Transformer Winding Hot Spot Temperature Based on Gated Recurrent Unit and Self-Attention and Temperature Lag
    Hao, Yuefeng
    Zhang, Zhanlong
    Liu, Xueli
    Yang, Yu
    Liu, Jun
    SENSORS, 2024, 24 (14)
  • [39] Coarse-to-Fine Tool Condition Monitoring using Multiple Gated Recurrent Units
    Xu, Huan
    Hong, Geok Soon
    Zhou, Jun Hong
    Hong, Jihoon
    Woon, Keng Soon
    45TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2019), 2019, : 3737 - 3742
  • [40] Attention-based residual improved U-Net model for continuous blood pressure monitoring by using photoplethysmography signal
    Yu, Mingzheng
    Huang, Zhiwen
    Zhu, Yidan
    Zhou, Panyu
    Zhu, Jianmin
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 75