Inversion Method for Transformer Winding Hot Spot Temperature Based on Gated Recurrent Unit and Self-Attention and Temperature Lag

被引:0
|
作者
Hao, Yuefeng [1 ]
Zhang, Zhanlong [1 ]
Liu, Xueli [1 ,2 ]
Yang, Yu [1 ]
Liu, Jun [3 ]
机构
[1] Chongqing Univ, Sch Elect Engn, Chongqing 400044, Peoples R China
[2] State Grid Sichuan Elect Power Co, Chengdu Power Supply Co, Chengdu 610041, Peoples R China
[3] Guizhou Power Grid Co Ltd, Elect Power Sci Res Inst, Guiyang 550002, Peoples R China
基金
中国国家自然科学基金;
关键词
winding hotspot temperature; temperature lag; mutual information (MI); SA-GRU; inversion method; PREDICTION;
D O I
10.3390/s24144734
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The hot spot temperature of transformer windings is an important indicator for measuring insulation performance, and its accurate inversion is crucial to ensure the timely and accurate fault prediction of transformers. However, existing studies mostly directly input obtained experimental or operational data into networks to construct data-driven models, without considering the lag between temperatures, which may lead to the insufficient accuracy of the inversion model. In this paper, a method for inverting the hot spot temperature of transformer windings based on the SA-GRU model is proposed. Firstly, temperature rise experiments are designed to collect the temperatures of the entire side and top of the transformer tank, top oil temperature, ambient temperature, the cooling inlet and outlet temperatures, and winding hot spot temperature. Secondly, experimental data are integrated, considering the lag of the data, to obtain candidate input feature parameters. Then, a feature selection algorithm based on mutual information (MI) is used to analyze the correlation of the data and construct the optimal feature subset to ensure the maximum information gain. Finally, Self-Attention (SA) is applied to optimize the Gate Recurrent Unit (GRU) network, establishing the GRU-SA model to perceive the potential patterns between output feature parameters and input feature parameters, achieving the precise inversion of the hot spot temperature of the transformer windings. The experimental results show that considering the lag of the data can more accurately invert the hot spot temperature of the windings. The inversion method proposed in this paper can reduce redundant input features, lower the complexity of the model, accurately invert the changing trend of the hot spot temperature, and achieve higher inversion accuracy than other classical models, thereby obtaining better inversion results.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] DIRECT MEASUREMENT OF TRANSFORMER WINDING HOT SPOT TEMPERATURE
    MCNUTT, WJ
    MCIVER, JC
    LEIBINGER, GE
    FALLON, DJ
    WICKERSHEIM, KA
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (06): : 1155 - 1162
  • [2] Inversion Detection of Transformer Transient Hot Spot Temperature
    Ruan, Jiangjun
    Deng, Yongqing
    Quan, Yu
    Gong, Ruohan
    IEEE ACCESS, 2021, 9 : 7751 - 7761
  • [3] Aerial Target Threat Assessment Based on Gated Recurrent Unit and Self-Attention Mechanism
    Chen, Chen
    Quan, Wei
    Shao, Zhuang
    Journal of Systems Engineering and Electronics, 2024, 35 (02) : 361 - 373
  • [4] Aerial target threat assessment based on gated recurrent unit and self-attention mechanism
    Chen, Chen
    Quan, Wei
    Shao, Zhuang
    JOURNAL OF SYSTEMS ENGINEERING AND ELECTRONICS, 2024, 35 (02) : 361 - 373
  • [5] Aerial target threat assessment based on gated recurrent unit and self-attention mechanism
    CHEN Chen
    QUAN Wei
    SHAO Zhuang
    JournalofSystemsEngineeringandElectronics, 2024, 35 (02) : 361 - 373
  • [6] Prediction of transformer average oil temperature and winding hot spot temperature by edge computation based on LSTSVR model
    Zhang L.
    Yang T.
    Li W.
    Liu Z.
    Zeng C.
    1600, Electric Power Automation Equipment Press (40): : 197 - 202
  • [7] RESEARCH ON TEMPERATURE RISE CALCULATION AND HOT SPOT TEMPERATURE INVERSION METHOD FOR OIL IMMERSED TRANSFORMER BASED ON MAGNETIC-THERMAL-FLUID
    Yuan, Fating
    Zhang, Naiyue
    Shi, Wenyu
    Gu, Lingyun
    Zeng, Jihao
    Tang, Bo
    THERMAL SCIENCE, 2024, 28 (4B): : 3307 - 3323
  • [8] Establishment and Verification of 10kV Oil Immersed Transformer Winding Hot Spot Temperature Inversion Model Based on Streamline Analysis
    Deng Y.
    Ruan J.
    Dong X.
    Huang D.
    Zhang C.
    Xian R.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (08): : 3191 - 3203
  • [9] Prediction of remaining useful life based on bidirectional gated recurrent unit with temporal self-attention mechanism
    Zhang, Jiusi
    Jiang, Yuchen
    Wu, Shimeng
    Li, Xiang
    Luo, Hao
    Yin, Shen
    RELIABILITY ENGINEERING & SYSTEM SAFETY, 2022, 221
  • [10] Influence of insulation paper on the hot spot temperature of oil-immersed transformer winding
    Luo, Chuan
    Zhao, Zhen-Gang
    Wang, Yu-Yuan
    Liang, Ke
    Zhang, Jia-Hong
    Li, Ying-Na
    Li, Chuan
    MODERN PHYSICS LETTERS B, 2021, 35 (28):