Inversion Method for Transformer Winding Hot Spot Temperature Based on Gated Recurrent Unit and Self-Attention and Temperature Lag

被引:0
|
作者
Hao, Yuefeng [1 ]
Zhang, Zhanlong [1 ]
Liu, Xueli [1 ,2 ]
Yang, Yu [1 ]
Liu, Jun [3 ]
机构
[1] Chongqing Univ, Sch Elect Engn, Chongqing 400044, Peoples R China
[2] State Grid Sichuan Elect Power Co, Chengdu Power Supply Co, Chengdu 610041, Peoples R China
[3] Guizhou Power Grid Co Ltd, Elect Power Sci Res Inst, Guiyang 550002, Peoples R China
基金
中国国家自然科学基金;
关键词
winding hotspot temperature; temperature lag; mutual information (MI); SA-GRU; inversion method; PREDICTION;
D O I
10.3390/s24144734
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The hot spot temperature of transformer windings is an important indicator for measuring insulation performance, and its accurate inversion is crucial to ensure the timely and accurate fault prediction of transformers. However, existing studies mostly directly input obtained experimental or operational data into networks to construct data-driven models, without considering the lag between temperatures, which may lead to the insufficient accuracy of the inversion model. In this paper, a method for inverting the hot spot temperature of transformer windings based on the SA-GRU model is proposed. Firstly, temperature rise experiments are designed to collect the temperatures of the entire side and top of the transformer tank, top oil temperature, ambient temperature, the cooling inlet and outlet temperatures, and winding hot spot temperature. Secondly, experimental data are integrated, considering the lag of the data, to obtain candidate input feature parameters. Then, a feature selection algorithm based on mutual information (MI) is used to analyze the correlation of the data and construct the optimal feature subset to ensure the maximum information gain. Finally, Self-Attention (SA) is applied to optimize the Gate Recurrent Unit (GRU) network, establishing the GRU-SA model to perceive the potential patterns between output feature parameters and input feature parameters, achieving the precise inversion of the hot spot temperature of the transformer windings. The experimental results show that considering the lag of the data can more accurately invert the hot spot temperature of the windings. The inversion method proposed in this paper can reduce redundant input features, lower the complexity of the model, accurately invert the changing trend of the hot spot temperature, and achieve higher inversion accuracy than other classical models, thereby obtaining better inversion results.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Dynamic Inversion Method of Hot Spot Temperature of Oil-immersed Transformer Based on Combination of Multiphysics Simulation and Neural Network Algorithm
    Ni Z.
    Sheng G.
    Zhang L.
    Wang F.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (06): : 2466 - 2477
  • [22] The Research of the Hot Spot Temperature of the Dry-type Transformer Winding Based on the Inversed-heat Conduction Model
    Zhang Xiaoxia
    Wang Yongqiang
    Li Changyuan
    MACHINERY, MATERIALS SCIENCE AND ENERGY ENGINEERING, 2015, : 831 - 839
  • [23] Multi-zone indoor temperature prediction based on Graph Attention Network and Gated Recurrent Unit
    Zhou, Chunxiang
    Xu, Zhanbo
    Wu, Jiang
    Liu, Kun
    Guan, Xiaohong
    IEEE International Conference on Automation Science and Engineering, 2021, 2021-August : 1973 - 1978
  • [24] Multi-zone indoor temperature prediction based on Graph Attention Network and Gated Recurrent Unit
    Zhou, Chunxiang
    Xu, Zhanbo
    Wu, Jiang
    Liu, Kun
    Guan, Xiaohong
    2021 IEEE 17TH INTERNATIONAL CONFERENCE ON AUTOMATION SCIENCE AND ENGINEERING (CASE), 2021, : 1973 - 1978
  • [25] A new method for transformer hot-spot temperature prediction based on dynamic mode decomposition
    Yang, Fan
    Wu, Tao
    Jiang, Hui
    Jiang, Jinyang
    Hao, Hanxue
    Zhang, Lianqiang
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 37
  • [26] Transformer hot spot temperature prediction based on basic operator information
    Rommel, D. P.
    Di Maio, D.
    Tinga, T.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 124
  • [27] Hot-spot Temperature Inversion for Metallized Film Capacitors Based on Conjugate Gradient Method
    Li, Haobo
    Li, Hua
    Zhang, Guohao
    Lan, Jing
    Lin, Fuchang
    Sun, Pei
    Gaodianya Jishu/High Voltage Engineering, 2024, 50 (09): : 4163 - 4170
  • [28] Reference Crop Evapotranspiration Prediction Based on Gated Recurrent Unit with Quantum Inspired Multi-head Self-attention Mechanism
    Gao, Zehai
    Yang, Dongzhe
    Li, Baojun
    Gao, Zijun
    Li, Chengcheng
    WATER RESOURCES MANAGEMENT, 2025, 39 (03) : 1481 - 1501
  • [29] Prediction of remaining useful life for rolling bearing based on ISOMAP and multi-head self-attention with gated recurrent unit
    Zhao, Qiwu
    Zhang, Xiaoli
    JOURNAL OF VIBRATION AND CONTROL, 2024,
  • [30] Micro-Expression Recognition Method Based on Transformer with Separable Self-Attention
    Yang, Peng
    Zeng, Zhifeng
    Zhu, Tianyuan
    2024 4TH INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND INTELLIGENT SYSTEMS ENGINEERING, MLISE 2024, 2024, : 90 - 95