Calibration of extremely low leak rate by static expansion

被引:0
|
作者
机构
[1] Yang, Changqing
[2] Li, Detian
[3] Cheng, Yongjun
[4] Feng, Yan
[5] Zhao, Lan
[6] Xi, Zhenhua
来源
Li, Detian | 1600年 / Science Press卷 / 34期
关键词
Mass spectrometers - Calibration - Ions;
D O I
10.13922/j.cnki.cjovst.2014.12.18
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A novel technique was developed to calibrate extremely low leak rate by static expansion. In the newly-developed calibration technique, the rising rate of He-ion current and calibration coefficient of quadrupole mass spectrometer were evaluated. Good repeatability was obtained in measuring the rising rate of He ion current, originated from an extremely low leak rate of the magnitude of 10-10 Pa·m3/s. Furthermore, a two-stage static expansion of a gas-mixture not only provides better calibration coefficient of the quadrupole mass spectrometer, but also bypasses the complicated expansion involved. The new technique was tested by calibrating a leak rate of 10-10 Pa·m3/s with satisfactory results. We suggest that with decreased volume of calibration chamber, the new technique may reduce the lower calibration limit down to 10 -13 Pa·m3/s.
引用
收藏
相关论文
共 50 条
  • [41] Calibration of reference leaks for testing leak sniffers
    Jitschin, Wolfgang
    Farangis, Baker
    VAKUUM IN FORSCHUNG UND PRAXIS, 2013, 25 (04) : 39 - 44
  • [42] Reference leak and calibration in BNM-LNE
    Legras, JC
    LeGuinio, J
    VIDE-SCIENCE TECHNIQUE ET APPLICATIONS, 1995, 51 (278): : 436 - &
  • [43] Real time calibration for ultrasensitive leak detection
    Chen, Xu
    Xiao, Libo
    Huang, Tianbin
    Shu, Yi
    Chen, Ping
    Cha, Liangzhen
    VACUUM, 2006, 81 (03) : 257 - 259
  • [44] CALIBRATION OF MASS-SPECTROMETRIC LEAK DETECTORS
    KUZMIN, VV
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1990, 26 (03): : 216 - 221
  • [45] Helium leak detectors. Design and calibration
    Piegay, B
    VIDE-SCIENCE TECHNIQUE ET APPLICATIONS, 1995, 51 (278): : 443 - &
  • [46] Compare different calibration method of pressure leak
    Zhang, Ruifang
    Feng, Yan
    Zhao, Lan
    Sheng, Xuemin
    Dong, Meng
    SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS, PTS 1-4, 2013, 303-306 : 349 - +
  • [47] Leak calibration by comparison with reference standard leaks
    Hidalgo, J.M.
    de Segovia, J.L.
    Vacuum, 2008, 82 (11) : 1151 - 1156
  • [48] CALIBRATION OF ULTRA SENSITIVE HELIUM LEAK DETECTORS
    BERGQUIST, LL
    SASAKI, YT
    VACUUM, 1985, 35 (12) : 631 - 631
  • [49] BANK RATE - NO LEAK IN SIGHT
    不详
    ECONOMIST, 1957, 185 (04): : 290 - 290
  • [50] Continuous surface cap model for ultra-high-performance concrete under static and low strain rate loadings: Calibration, experiment, and simulation
    Liang, Shi-Lin
    Yu, Jun
    Fang, Qin
    INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2024, 185