Calibration of extremely low leak rate by static expansion

被引:0
|
作者
机构
[1] Yang, Changqing
[2] Li, Detian
[3] Cheng, Yongjun
[4] Feng, Yan
[5] Zhao, Lan
[6] Xi, Zhenhua
来源
Li, Detian | 1600年 / Science Press卷 / 34期
关键词
Mass spectrometers - Calibration - Ions;
D O I
10.13922/j.cnki.cjovst.2014.12.18
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A novel technique was developed to calibrate extremely low leak rate by static expansion. In the newly-developed calibration technique, the rising rate of He-ion current and calibration coefficient of quadrupole mass spectrometer were evaluated. Good repeatability was obtained in measuring the rising rate of He ion current, originated from an extremely low leak rate of the magnitude of 10-10 Pa·m3/s. Furthermore, a two-stage static expansion of a gas-mixture not only provides better calibration coefficient of the quadrupole mass spectrometer, but also bypasses the complicated expansion involved. The new technique was tested by calibrating a leak rate of 10-10 Pa·m3/s with satisfactory results. We suggest that with decreased volume of calibration chamber, the new technique may reduce the lower calibration limit down to 10 -13 Pa·m3/s.
引用
收藏
相关论文
共 50 条
  • [31] Extremely Low Ablation Rate of Metals Using Xecl Excimer Laser
    Kusaba, Mitsuhiro
    Hashida, Masaki
    Sakabe, Shuji
    JOURNAL OF LASER MICRO NANOENGINEERING, 2018, 13 (01): : 17 - 20
  • [32] Devices, Facilities, and Shielding for Biological Experiments With Static and Extremely Low Frequency Magnetic Fields
    Makinistian, Leonardo
    Vives, Leandro
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2024,
  • [33] Exposure to Static and Extremely-Low Frequency Electromagnetic Fields and Cellular Free Radicals
    Lai, Henry
    ELECTROMAGNETIC BIOLOGY AND MEDICINE, 2019, 38 (04) : 231 - 248
  • [34] Weak Static and Extremely Low Frequency Magnetic Fields Affect In Vitro Pollen Germination
    Betti, Lucietta
    Trebbi, Grazia
    Fregola, Fabio
    Zurla, Michela
    Mesirca, Pietro
    Brizzi, Maurizio
    Borghini, Francesco
    THESCIENTIFICWORLDJOURNAL, 2011, 11 : 875 - 890
  • [35] The antitumor effect of static and extremely low frequency magnetic fields against nephroblastoma and neuroblastoma
    Yuan, Lin-Qing
    Wang, Can
    Zhu, Kun
    Li, Hua-Mei
    Gu, Wei-Zhong
    Zhou, Dong-Ming
    Lai, Jia-Qi
    Zhou, Duo
    Lv, Yao
    Tofani, Santi
    Chen, Xi
    BIOELECTROMAGNETICS, 2018, 39 (05) : 375 - 385
  • [37] Low Flow Rate Measurement and Leak Detection for Health Monitoring of Water Equipment
    Yazdi, Armin
    Tsai, Li-Chih
    Rezaee, Maysam
    Gore, Sarang
    Salowitz, Nathan
    EUROPEAN WORKSHOP ON STRUCTURAL HEALTH MONITORING (EWSHM 2022), VOL 3, 2023, : 963 - 971
  • [38] Maximal static expansion
    Barthou, D
    Cohen, A
    Collard, JF
    INTERNATIONAL JOURNAL OF PARALLEL PROGRAMMING, 2000, 28 (03) : 213 - 243
  • [39] Maximal Static Expansion
    Denis Barthou
    Albert Cohen
    Jean-François Collard
    International Journal of Parallel Programming, 2000, 28 : 213 - 243
  • [40] A new static method of calibration for low-cost laser triangulation systems
    Zhao, Yihui
    Supri, Taufik Bin Mohamed
    Yang, Song
    Qin, Yi
    MEASUREMENT, 2020, 156 (156)