Calibration of extremely low leak rate by static expansion

被引:0
|
作者
机构
[1] Yang, Changqing
[2] Li, Detian
[3] Cheng, Yongjun
[4] Feng, Yan
[5] Zhao, Lan
[6] Xi, Zhenhua
来源
Li, Detian | 1600年 / Science Press卷 / 34期
关键词
Mass spectrometers - Calibration - Ions;
D O I
10.13922/j.cnki.cjovst.2014.12.18
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A novel technique was developed to calibrate extremely low leak rate by static expansion. In the newly-developed calibration technique, the rising rate of He-ion current and calibration coefficient of quadrupole mass spectrometer were evaluated. Good repeatability was obtained in measuring the rising rate of He ion current, originated from an extremely low leak rate of the magnitude of 10-10 Pa·m3/s. Furthermore, a two-stage static expansion of a gas-mixture not only provides better calibration coefficient of the quadrupole mass spectrometer, but also bypasses the complicated expansion involved. The new technique was tested by calibrating a leak rate of 10-10 Pa·m3/s with satisfactory results. We suggest that with decreased volume of calibration chamber, the new technique may reduce the lower calibration limit down to 10 -13 Pa·m3/s.
引用
收藏
相关论文
共 50 条
  • [1] Leak rate calibration system
    Shin, YH
    Hong, SS
    Lim, IT
    Chung, KH
    ADVANCES IN NONDESTRUCTIVE EVALUATION, PT 1-3, 2004, 270-273 : 1674 - 1678
  • [2] GAUGE CALIBRATION AT EXTREMELY LOW PRESSURES
    BERGQUIS.LE
    VACUUM, 1968, 18 (03) : 153 - &
  • [3] GAS FLOW-RATE MEASUREMENTS FOR LEAK CALIBRATION
    BERGOGLIO, M
    CALCATELLI, A
    RUMIANO, G
    VACUUM, 1995, 46 (8-10) : 763 - 765
  • [4] Leak rate calibration with gas flow standard apparatus
    Zhang, DX
    Liu, SL
    Li, DT
    Yang, M
    Liu, QA
    Li, WK
    VACUUM, 1996, 47 (6-8) : 515 - 517
  • [5] Study on Vacuum Leak Calibration Technology Based on Static Cumulative Comparison Method
    Zhao Lan
    Cheng Yong-jun
    Sun Wen-jun
    Chen Lian
    Li Ya-li
    Feng Tian-you
    2018 5TH IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR AEROSPACE (METROAEROSPACE), 2018, : 640 - 644
  • [6] Calibration of inductive voltage dividers at extremely low frequencies
    Tarach, D
    Trenkler, G
    METROLOGIA, 1996, 32 (05) : 367 - 370
  • [7] Calibration of inductive voltage dividers at extremely low frequencies
    Universitaet der Bundeswehr Hamburg, Hamburg, Germany
    Metrologia, 5 (367-370):
  • [8] ABSOLUTE CALIBRATION OF ANTENNAS AT EXTREMELY LOW-FREQUENCIES
    CLAYTON, MD
    POLK, C
    ETZOLD, H
    COOPER, WW
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1973, AP21 (04) : 514 - 523
  • [9] PULMONARY AIR LEAK IN EXTREMELY LOW-BIRTH-WEIGHT INFANTS
    YU, VYH
    WONG, PY
    BAJUK, B
    SZYMONOWICZ, W
    ARCHIVES OF DISEASE IN CHILDHOOD, 1986, 61 (03) : 239 - 241
  • [10] ION GAUGE CALIBRATION AT LOW PRESSURES USING LEAK DETECTOR
    BERGSNOVHANSON, B
    ENDOW, N
    PASTERNAK, RA
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1964, 1 (01): : 7 - &