Effect of DC bias on transient transferring characteristics of current transformer

被引:0
|
作者
Key Laboratory of Power System Intelligent Dispatch and Control of Ministry of Education, Shandong University, Ji'nan [1 ]
250061, China
机构
来源
基金
中国国家自然科学基金;
关键词
Power quality - Transients - DC transformers - Electric fault currents - Electric power system protection - Transformer protection - Electric power transmission networks - Geomagnetism - MATLAB;
D O I
10.16081/j.issn.1006-6047.2015.12.019
中图分类号
学科分类号
摘要
As the DC bias caused by HVDC power transmission and geomagnetic induction becomes more serious, its effect on the transient transferring characteristics of CT(Current Transformer) should be analyzed. An equivalent analysis model is built and the effects of DC bias and initial fault angle on the transient transferring characteristics of CT, especially the initial saturation time, are deduced and analyzed in detail. The transient transferring characteristic parameters of an operating CT in an actual power grid are calculated by MATLAB programs and the quantitative relations between the DC bias current and the initial saturation time, between the DC bias current and the fundamental of secondary current and between the DC bias current and the second-order harmonic of secondary current are obtained. The conclusions of analysis provide the references for understanding the working state of CT with DC bias and for the setting of relay protections. © 2015, Electric Power Automation Equipment Press. All right reserved.
引用
收藏
相关论文
共 50 条
  • [31] Study on the Effects of the DC Bias on the Harmonic Characteristics of the New Converter Transformer
    Li, Yong
    Luo, Longfu
    He, Dajiang
    Rehtanz, Christian
    Yang, Dechang
    Rueberg, Sven
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [32] Transient current measurement for power system by using improved AC/DC current transformer
    Ren, S.
    Zhang, Z.
    Liu, X.
    Huazhong Ligong Daxue Xuebao/Journal Huazhong (Central China) University of Science and Technology, 2001, 29 (11): : 85 - 87
  • [33] Influence of Direct Current Bias on Vibration Characteristics of Converter Transformer
    Wang, Hao
    Zhang, Li
    Sun, Youliang
    Zhang, Zhuangzhuang
    Wang, Dong
    2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 372 - 377
  • [34] A Dual Rising Edge Shift Algorithm for Eliminating the Transient DC-Bias Current in Transformer for a Dual Active Bridge Converter
    Gierczynski, Michal
    Grzesiak, Lech M.
    Kaszewski, Arkadiusz
    ENERGIES, 2021, 14 (14)
  • [35] Effect of Voltage Bias on the dc SQUID Characteristics
    M. Kiviranta
    H. Seppä
    Journal of Low Temperature Physics, 2001, 123 : 127 - 136
  • [36] Effect of voltage bias on the dc SQUID characteristics
    Kiviranta, M
    Seppä, H
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2001, 123 (1-2) : 127 - 136
  • [37] Research on Modeling Method of Transformer DC Bias Caused by Metro Stray Current
    Ni Yan-Ru
    Zeng Xiang-Jun
    Yu Kun
    Leng Yang
    Peng Ping
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3834 - 3839
  • [38] Analysis of the DC Fault Current Limiting Characteristics of a DC Superconducting Fault Current Limiter Using a Transformer
    Cho, Kang-Cheol
    Park, Min-Ki
    Lim, Sung-Hun
    ENERGIES, 2020, 13 (16)
  • [39] Research on DC Bias Saturation Characteristics of Transformer Combining CEEMD and FuzzyEn Method
    Liu, Xingmou
    Lu, Rui
    Yang, Ning
    Xiao, Yao
    Jadoon, Ammad
    ENGINEERING LETTERS, 2024, 32 (10) : 1888 - 1900
  • [40] Research on Electromagnetic Characteristics of Single-Phase Transformer under DC Bias
    Yan, Xiaoli
    Dong, Xia
    Han, Guozheng
    Yu, Xiaodong
    2022 IEEE/IAS INDUSTRIAL AND COMMERCIAL POWER SYSTEM ASIA (I&CPS ASIA 2022), 2022, : 34 - 38