Effect of DC bias on transient transferring characteristics of current transformer

被引:0
|
作者
Key Laboratory of Power System Intelligent Dispatch and Control of Ministry of Education, Shandong University, Ji'nan [1 ]
250061, China
机构
来源
基金
中国国家自然科学基金;
关键词
Power quality - Transients - DC transformers - Electric fault currents - Electric power system protection - Transformer protection - Electric power transmission networks - Geomagnetism - MATLAB;
D O I
10.16081/j.issn.1006-6047.2015.12.019
中图分类号
学科分类号
摘要
As the DC bias caused by HVDC power transmission and geomagnetic induction becomes more serious, its effect on the transient transferring characteristics of CT(Current Transformer) should be analyzed. An equivalent analysis model is built and the effects of DC bias and initial fault angle on the transient transferring characteristics of CT, especially the initial saturation time, are deduced and analyzed in detail. The transient transferring characteristic parameters of an operating CT in an actual power grid are calculated by MATLAB programs and the quantitative relations between the DC bias current and the initial saturation time, between the DC bias current and the fundamental of secondary current and between the DC bias current and the second-order harmonic of secondary current are obtained. The conclusions of analysis provide the references for understanding the working state of CT with DC bias and for the setting of relay protections. © 2015, Electric Power Automation Equipment Press. All right reserved.
引用
收藏
相关论文
共 50 条
  • [21] Analysis of DC bias exciting current of the single-phase transformer and its effect on protection
    Zhu, Lin
    Wei, Chen
    Yu, Yang
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (24): : 158 - 162
  • [22] Excitation current and vibration characteristics of DC biased transformer
    Pan, Chao
    Wang, Chengjian
    Su, Hao
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2021, 7 (03): : 604 - 613
  • [23] Core form transformer topological duality based transient model validation for exciting current calculation within DC bias
    Li, Jinlong
    Li, Jinzhong
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (15) : 3099 - 3107
  • [24] Research on Winding Current of UHV Transformer under DC-Bias
    Li B.
    Wang Z.
    Liu K.
    Yang X.
    Li M.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 (07): : 1422 - 1431
  • [25] Simulation Study of the Influence of Stray Current on DC Bias of Power Transformer
    Zhang, Jingzhuo
    Song, Xinming
    Xiao, Li
    Chen, Long
    Wu, Guoxing
    Cui, Yuzhong
    Lai, Zhenyu
    Li, Qiyuan
    2020 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL, AUTOMATION AND MECHANICAL ENGINEERING, 2020, 1626
  • [26] RESEARCH ON DC BIAS CURRENT MONITORING OF POWER TRANSFORMER NEUTRAL POINT
    Liu, Chuang
    Zhou, Xingxing
    Tian, Haoyang
    Zhao, Yang
    Qu, Tinghua
    Chen, Wenzhong
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [27] DC magnetic bias induced current effects on transformer and restricting methods
    School of Electrical Engineering, Wuhan University, Wuhan 430072, China
    不详
    Gaodianya Jishu, 2006, 9 (117-120):
  • [28] Research on Characterization of Core Vibration by Abnormal Current of DC Bias Transformer
    Pan C.
    Su H.
    Cai G.
    Chen X.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 (09): : 1868 - 1879
  • [29] Influence analysis of DC bias on vibration characteristics of 500 kV transformer
    He L.
    Wu T.
    Li R.
    Ding D.
    Yang J.
    Li S.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2024, 44 (02): : 133 - 138
  • [30] Model Test for Harmonic Characteristics of Convertor Transformer under Dc Bias
    Li Hua
    Lin Fu-chang
    Gui Zhong
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 4436 - 4439