Fault analysis of internal stator windings in synchronous generators based on R/S and wavelet transform

被引:0
|
作者
Xia, Changliang [1 ]
Jin, Xuefeng [1 ]
Fang, Hongwei [1 ]
Shi, Tingna [1 ]
机构
[1] Tianjin University, Tianjin 300072, China
关键词
Calculations - Electric potential - Electric windings - Fractals - Frequency domain analysis - Stators - Time domain analysis - Wavelet transforms;
D O I
暂无
中图分类号
学科分类号
摘要
The internal stator winding fault of synchronous generator, which is common and destructive, greatly affects the security of the generator and the power network. Therefore, it is important to detect the fault very effectively. While the detection for the internal stator winding fault in synchronous generator is always difficult. This paper has tried to apply a new method, i.e. Rescaled Range method and wavelet transform for the analysis of the fault. Considering the feature of the harmonic component in phase voltage or phase current which is caused by the fault of stator winding and the excellent localization characteristic of wavelet transform in time and frequency domain, the fault characteristic is obtained by calculating the fractal dimension of the transformed fault signal using the R/S method. This method provides a new idea for the detection of the internal stator winding fault in synchronous generator.
引用
收藏
页码:101 / 105
相关论文
共 50 条
  • [41] A novel protection scheme for synchronous generator stator windings based on SVM
    Magdi El-Saadawi
    Ahmed Hatata
    Protection and Control of Modern Power Systems, 2017, 2 (1)
  • [42] A new method for loss of excitation protection of synchronous generators in the presence of static synchronous compensator based on the discrete wavelet transform
    Dolatabadi, Shahab
    Seyedi, Heresh
    Tohidi, Sajjad
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 209
  • [43] ONLINE AND OFFLINE VIBRATION ANALYSIS OF STATOR END WINDINGS OF LARGE POWER GENERATORS
    Thien, Dagmar
    Romanowski, Holger
    Strack, Sebastian
    Kempen, Stefan
    Krol, Thorsten
    Langmann, Axel
    PROCEEDINGS OF THE ASME TURBO EXPO 2008, VOL 5, PT A, 2008, : 565 - 572
  • [44] Modeling and Simulation of Internal Faults in Salient-pole Synchronous Generators with Wave Windings
    Sinha, Amrita
    Vishwakarma, D. N.
    Srivastava, R. K.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2010, 38 (01) : 100 - 114
  • [45] Modeling Analysis and Tolerant Capability for Stator Winding Interturn Fault in Synchronous Reluctance Motor With Series and Parallel Connected Windings
    Krishna, Merugu Siva Rama
    Seshadrinath, Jeevanand
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2025, 72 (03) : 3136 - 3147
  • [46] A Fault Diagnosis Strategy for Stator Windings Inter-turn Short Circuit of Synchronous Condenser
    Wang, Xiaohu
    Xu, Songmei
    Ye, Yuanling
    Tian, Weijie
    Yang, Chaowei
    Wang, Wei
    Wei, Chao
    2021 24TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2021), 2021, : 2616 - 2620
  • [47] Wavelet transform-based fault detection method for hydrogen energy-based distributed generators
    Bayrak, Gokay
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (44) : 20293 - 20308
  • [48] Condition Monitoring and Fault Diagnosis of Permanent Magnet Synchronous Motor Stator Winding Using the Continuous Wavelet Transform and Machine Learning
    Pietrzak, Przemyslaw
    Wolkiewicz, Marcin
    POWER ELECTRONICS AND DRIVES, 2024, 9 (01) : 106 - 121
  • [49] Experimental Verification of a Novel Adaptive Stator Ground Fault Protection Scheme for Synchronous Generators
    Al Jaafari, Khaled
    Negandari, Amir
    Toliyat, Hamid A.
    Safari-Shad, Nader
    Franklin, Russ
    2016 XXII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2016, : 2237 - 2243
  • [50] Evaluation of the Grounding Circuit Measurements for Stator Ground-Fault Location of Synchronous Generators
    Blanquez, F. R.
    Rebollo, E.
    Platero, C. A.
    2013 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2013, : 229 - 233