Myelin water imaging of in vivo and ex vivo human brains using multi-echo gradient echo at 3T and 7T

被引:0
|
作者
Xu, Guojun [1 ]
Zhao, Zhiyong [2 ]
Zhu, Qinfeng [1 ]
Zhu, Keqing [3 ,4 ,5 ,6 ]
Zhang, Jing [3 ,4 ,5 ,6 ]
Wu, Dan [1 ]
机构
[1] Zhejiang Univ, Dept Biomed Engn, Coll Biomed Engn & Instrument Sci, Key Lab Biomed Engn Minist Educ, Hangzhou, Peoples R China
[2] Zhejiang Univ, Childrens Hosp, Natl Clin Res Ctr Child Hlth, Sch Med, Hangzhou, Peoples R China
[3] Zhejiang Univ, China Brain Bank, Sch Med, Hangzhou, Peoples R China
[4] Zhejiang Univ, Dept Neurol, Affiliated Hosp 2,Sch Med, Key Lab Med Neurobiol Zhejiang Prov, Hangzhou, Peoples R China
[5] Zhejiang Univ, Dept Neurobiol, Sch Med, Hangzhou, Peoples R China
[6] Zhejiang Univ, First Affiliated Hosp & Sch Med, Dept Pathol, Hangzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
multi-echo gradient-echo; myelin water fraction; 3; T; 7; ex vivo; histological staining; MRI; RELAXATION; SCLEROSIS; FRACTION; POSTMORTEM; VISUALIZATION; COMPONENT; WHOLE; TIME;
D O I
10.1002/mrm.30310
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the myelin water fraction (MWF) measurements between 3 T and 7 T and between in vivo and ex vivo human brains, and to investigate the relationship between multi-echo gradient-echo (mGRE)-based 3D MWF and myelin content using histological staining, which has not been validated in the human brain. Methods: In this study, we performed 3D mGRE-based MWF measurements on five ex vivo human brain hemispheres and five healthy volunteers at 3 T and 7 T with 1mm isotropic resolution. The data were fitted with the T-2* based on a three compartment complex-valued model to estimate MWF. We obtained myelin basic protein (MBP) staining from two tissue blocks and co-registered the MWF map and histology image for voxel-wise correlation between the two. Results: The MWF values measured from 7 T were overall higher than 7 T, but data between the two field strength demonstrated high correlations both in vivo (r=0.88) and ex vivo (r=0.83) across 19 white matter regions. Moreover, the MWF measurements showed a good agreement between in vivo and ex vivo assessments at 3 T (r=0.61) and 7 T (r=0.54). Based on MBP staining, the MWF values exhibited strong positive correlations with myelin content on both 3 T (r=0.68 and r=0.78 for the two tissue blocks) and 7 T (r=0.64 and r=0.82 for the two tissue blocks). Conclusion: The findings demonstrated that the mGRE-based MWF mapping can be used to quantify myelin content in the human brain, despite the field-strength dependency of the measurements.
引用
收藏
页码:803 / 813
页数:11
相关论文
共 50 条
  • [41] Direct comparison of the quality of 32 echo MRI T2 decays used to measure myelin water in vivo at 3T and 1.5T using the decay roughness measure
    Cover, K. S.
    de Graaf, W.
    Soriano, A. Lopez
    Kuijer, J. P. A.
    Steenwijk, M. D.
    Geurts, J. J. G.
    van Dijk, B. W.
    Vrenken, H.
    Barkhof, F.
    MULTIPLE SCLEROSIS JOURNAL, 2011, 17 : S371 - S372
  • [42] Comparison of multi-echo and single-echo gradient-recalled echo sequences for SPIO-enhanced Liver MRI at 3 T
    Choi, J. S.
    Kim, M-J
    Kim, J. H.
    Choi, J-Y
    Chung, Y. E.
    Park, M-S
    Kim, K. W.
    CLINICAL RADIOLOGY, 2010, 65 (11) : 916 - 923
  • [43] Measuring Lung Water: Ex Vivo Validation of Multi-image Gradient Echo MRI
    Holverda, Sebastiaan
    Theilmann, Rebecca J.
    Sa, Rui C.
    Arai, Tatsuya J.
    Hall, Evan T.
    Dubowitz, David J.
    Prisk, G. Kim
    Hopkins, Susan R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (01) : 220 - 224
  • [44] Myelin water imaging at 0.55 T using a multigradient-echo sequence
    Schaeper, Jessica
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (03) : 1043 - 1056
  • [45] Improved Resting-State Functional MRI Using Multi-Echo Echo-Planar Imaging on a Compact 3T MRI Scanner with High-Performance Gradients
    Kang, Daehun
    In, Myung-Ho
    Jo, Hang Joon
    Halverson, Maria A.
    Meyer, Nolan K.
    Ahmed, Zaki
    Gray, Erin M.
    Madhavan, Radhika
    Foo, Thomas K.
    Fernandez, Brice
    Black, David F.
    Welker, Kirk M.
    Trzasko, Joshua D.
    Huston III, John
    Bernstein, Matt A.
    Shu, Yunhong
    SENSORS, 2023, 23 (09)
  • [46] Mapping of the internal structure of human habenula with ex vivo MRI at 7T
    Strotmann, Barbara
    Koegler, Carsten
    Bazin, Pierre-Louis
    Weiss, Marcel
    Villringer, Arno
    Turner, Robert
    FRONTIERS IN HUMAN NEUROSCIENCE, 2013, 7
  • [47] A comparison of multi-echo spin-echo and triple-echo steady-state T2 mapping for in vivo evaluation of articular cartilage
    Juras, Vladimir
    Bohndorf, Klaus
    Heule, Rahel
    Kronnerwetter, Claudia
    Szomolanyi, Pavol
    Hager, Benedikt
    Bieri, Oliver
    Zbyn, Stefan
    Trattnig, Siegfried
    EUROPEAN RADIOLOGY, 2016, 26 (06) : 1905 - 1912
  • [48] Robust Myelin Quantitative Imaging from Multi-echo T2 MRI Using Edge Preserving Spatial Priors
    Shen, Xiaobo
    Nguyen, Thanh D.
    Gauthier, Susan A.
    Raj, Ashish
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION (MICCAI 2013), PT I, 2013, 8149 : 622 - 630
  • [49] A comparison of multi-echo spin-echo and triple-echo steady-state T2 mapping for in vivo evaluation of articular cartilage
    Vladimir Juras
    Klaus Bohndorf
    Rahel Heule
    Claudia Kronnerwetter
    Pavol Szomolanyi
    Benedikt Hager
    Oliver Bieri
    Stefan Zbyn
    Siegfried Trattnig
    European Radiology, 2016, 26 : 1905 - 1912
  • [50] T2-weighted prostate imaging using echo-planar imaging at 3T
    Ragan, D
    Ma, J
    MEDICAL PHYSICS, 2005, 32 (06) : 1911 - 1911