A simple spectrogram model for high-accuracy spectral calibration of VIPA spectrometers

被引:1
|
作者
Zhou, Hao [1 ,2 ]
Zhao, Weixiong [1 ,2 ]
Cui, Weihua [1 ]
Lv, Bingxuan [1 ,2 ]
Fang, Bo [1 ]
Yang, Nana [1 ]
Xiang, Guangfeng [1 ]
Zhang, Weijun [1 ]
Deng, Lunhua [3 ]
Chen, Weidong [4 ]
机构
[1] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Hefei Inst Phys Sci, Lab Atmospher Physicochem, Hefei 230031, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Peoples R China
[3] East China Normal Univ, State Key Lab Precis Spect, Shanghai 200062, Peoples R China
[4] Univ Littoral Cote dOpale, Lab Physicochim Atmosphere, F-59140 Dunkerque, France
基金
中国国家自然科学基金;
关键词
FREQUENCY COMB SPECTROSCOPY; WAVELENGTH DEMULTIPLEXER; REDUCTION ALGORITHM;
D O I
10.1039/d4an00965g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The virtually imaged phased array (VIPA) spectrometer uses the orthogonal dispersion method and has the advantages of compact structure, high spectral resolution, and wide wavelength coverage. It has been widely used in different fields. However, due to the non-linear dispersion of the VIPA etalon and the cross-dispersion structure of the VIPA spectrometer, simple and high-accuracy wavelength calibration remains a challenge. In this paper, a new and simple five-parameter spectrogram model is developed by simplifying the phase-matching equation of the VIPA etalon and considering the angle between the camera and dispersion direction, which can achieve a frequency accuracy better than one pixel. The performance of the model is demonstrated by measuring the CO2 absorption spectrum in the range of 1.42 to 1.45 mu m using a self-designed near-infrared VIPA spectrometer . The reported method is simple and easy to solve with high accuracy, which is conducive to promoting the application of VIPA spectrometers in precision measurement. A simple five-parameters spectrogram model for the VIPA spectrometer frequency calibration is developed, which has the advantages of high accuracy, simple setup and easy-to-solve.
引用
收藏
页码:5455 / 5462
页数:8
相关论文
共 50 条
  • [21] HIGH-ACCURACY CALIBRATION OF OPTICAL IMAGING INSTRUMENTS IN SPACE
    OMONGAIN, E
    GOODMAN, M
    REYNOLDS, M
    CONNOR, CB
    ESA JOURNAL-EUROPEAN SPACE AGENCY, 1983, 7 (03): : 299 - 309
  • [22] High-Accuracy Image Formation Model for Coded Aperture Snapshot Spectral Imaging
    Song, Lingfei
    Wang, Lizhi
    H. Kim, Min
    Huang, Hua
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2022, 8 : 188 - 200
  • [23] Camera model and calibration process for high-accuracy digital image metrology of inspection planes
    Correia, B
    Dinis, J
    MACHINE VISION SYSTEMS FOR INSPECTION AND METROLOGY VII, 1998, 3521 : 42 - 53
  • [24] High-accuracy detector calibration in the 3-1500 eV spectral range at the PTB radiometry laboratory
    Scholze, F
    Henneken, H
    Kuschnerus, P
    Rabus, H
    Richter, M
    Ulm, G
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 866 - 868
  • [25] High-accuracy detector calibration in the 3-1500 eV spectral range at the PTB radiometry laboratory
    Phys.-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin, Germany
    J. Synchrotron Radiat., 3 (866-868):
  • [26] High-accuracy and rapid azimuth calibration for polarizing elements in ellipsometry by differential spectral analysis on the ellipse azimuth
    Tu, Huatian
    Zheng, Yuxiang
    Shan, Yao
    Chen, Yao
    Zhang, Haotian
    Zhang, Rongjun
    Wang, Songyou
    Lee, YoungPak
    Chen, Liangyao
    APPLIED OPTICS, 2021, 60 (06) : 1609 - 1614
  • [27] HIGH-ACCURACY SPECTROMETER FOR MEASUREMENT OF REGULAR SPECTRAL TRANSMITTANCE
    MANOOCHEHRI, F
    IKONEN, E
    APPLIED OPTICS, 1995, 34 (19): : 3686 - 3692
  • [28] High-accuracy spectral reduction algorithm for the echelle spectrometer
    Yin, Lu
    Bayanheshig
    Yang, Jin
    Lu, Yuxian
    Zhang, Rui
    Sun, Ci
    Cui, Jicheng
    APPLIED OPTICS, 2016, 55 (13) : 3574 - 3581
  • [29] High-accuracy measurement of specular spectral reflectance and transmittance
    Haapalinna, A
    Manoochehri, F
    Ikonen, E
    ANALYTICA CHIMICA ACTA, 1999, 380 (2-3) : 317 - 325
  • [30] The PTB high-accuracy spectral responsivity scale in the ultraviolet
    Richter, M
    Johannsen, U
    Kuschnerus, P
    Kroth, U
    Rabus, H
    Ulm, G
    Werner, L
    METROLOGIA, 2000, 37 (05) : 515 - 518