Partial volume effect and its influence factors for sphere lesion PET images

被引:0
|
作者
机构
[1] Chen, Ying-Mao
[2] Geng, Jian-Hua
[3] Tian, Jia-He
[4] Xu, Bai-Xuan
[5] Yao, Shu-Lin
[6] Shao, Ming-Zhe
来源
Chen, Y.-M. | 1600年 / Atomic Energy Press卷 / 48期
关键词
Computer simulation experiment - Influence factor - Lesion diameter - Lesion image - Partial volume effect - Pixel values - Positron emission tomography (PET) - System resolution;
D O I
10.7538/yzk.2014.48.06.1136
中图分类号
学科分类号
摘要
To investigate the partial volume effect (PVE) and its influence factors for sphere lesion positron emission tomography (PET) images and provide the basis for PVE correction, the computer simulation experiments for PET imaging were performed. According to the theory of PVE formation, PET images of the sphere lesions with diameter of 2-30 mm were simulated with computer program in the ratio of background to lesion of 0-0.7 under system resolution of 3-15 mm. The maximum and the average pixel values and the width of the lesion images were calculated. The results show that the maximum and average pixel values increase with the lesion diameter in S shape under every system resolution and background. The maximum and average pixel values decrease in inverse S shape with the increasing of the system resolution under every lesion diameter and background. The maximum and average pixel values linearly increase with the increasing of background under every lesion diameter and system resolution. The width of the lesion image is independent of the background under every lesion diameter and system resolution. The FWHM of the lesion image is close to the lesion diameter for the lesion which size is larger than system resolution and the difference increases with the system resolution value, it doesn't change with the lesions which size is smaller than system resolution and it is equal to the system resolution.
引用
收藏
相关论文
共 50 条
  • [41] Partial volume effect estimation and correction in the aortic vascular wall in PET imaging
    Burg, S.
    Dupas, A.
    Stute, S.
    Dieudonne, A.
    Huet, P.
    Le Guludec, D.
    Buvat, I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (21): : 7527 - 7542
  • [42] A Correction of Partial Volume Effect for Using PET to Define Metabolically Active Tumor Volume for Pancreatic Cancer
    Dalah, E.
    Cungeng, Y.
    Moraru, I.
    Erickson, B.
    Li, X.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [43] The effect of partial volume effect correction on PIB and FDG PET data in MCI and AD patients
    Shiga, Tohru
    Miederer, Isabelle
    Herrmann, Ken
    Henriksen, Gjermund
    Praus, Christine
    Schwaiger, Markus
    Drzezga, Alexander
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [44] Imaging the choroid plexus for partial volume correction of (R)-[C-11]verapamil PET images
    Wang, Shaonan
    Feldmann, Maria
    Hinz, Rainer
    Koepp, Matthias
    Asselin, Marie-Claude
    Jackson, Alan
    NEUROIMAGE, 2010, 52 : S188 - S188
  • [45] A SINGLE SCAN METHOD FOR ASSESSING PARTIAL VOLUME EFFECTS AND QUANTITATIVE ACCURACY IN PET& SPECT IMAGES
    Bailey, Dale
    Willowson, Kathy
    Munoz-Ferrada, Carl
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [46] MRI-based partial volume correction method for brain FDG-PET images.
    Yang, J
    Huang, SC
    Small, GW
    Phelps, ME
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 161 - 161
  • [47] An MR image-guided, voxel-based partial volume correction method for PET images
    Wang, Hesheng
    Fei, Baowei
    MEDICAL PHYSICS, 2012, 39 (01) : 179 - 194
  • [48] Partial Volume Correction in PET Images: A Single Correction Method Applied for Multiple Source to Background Ratios
    Piper, J.
    Shen, G.
    Nelson, A. D.
    Nelson, A. S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [49] Influence of Co-57 and CT Transmission Measurements on the Quantification Accuracy and Partial Volume Effect of a Small Animal PET Scanner
    Mannheim, Julia G.
    Schmid, Andreas M.
    Pichler, Bernd J.
    MOLECULAR IMAGING AND BIOLOGY, 2017, 19 (06) : 825 - 836
  • [50] Influence of Co-57 and CT Transmission Measurements on the Quantification Accuracy and Partial Volume Effect of a Small Animal PET Scanner
    Julia G. Mannheim
    Andreas M. Schmid
    Bernd J. Pichler
    Molecular Imaging and Biology, 2017, 19 : 825 - 836