Partial volume effect and its influence factors for sphere lesion PET images

被引:0
|
作者
机构
[1] Chen, Ying-Mao
[2] Geng, Jian-Hua
[3] Tian, Jia-He
[4] Xu, Bai-Xuan
[5] Yao, Shu-Lin
[6] Shao, Ming-Zhe
来源
Chen, Y.-M. | 1600年 / Atomic Energy Press卷 / 48期
关键词
Computer simulation experiment - Influence factor - Lesion diameter - Lesion image - Partial volume effect - Pixel values - Positron emission tomography (PET) - System resolution;
D O I
10.7538/yzk.2014.48.06.1136
中图分类号
学科分类号
摘要
To investigate the partial volume effect (PVE) and its influence factors for sphere lesion positron emission tomography (PET) images and provide the basis for PVE correction, the computer simulation experiments for PET imaging were performed. According to the theory of PVE formation, PET images of the sphere lesions with diameter of 2-30 mm were simulated with computer program in the ratio of background to lesion of 0-0.7 under system resolution of 3-15 mm. The maximum and the average pixel values and the width of the lesion images were calculated. The results show that the maximum and average pixel values increase with the lesion diameter in S shape under every system resolution and background. The maximum and average pixel values decrease in inverse S shape with the increasing of the system resolution under every lesion diameter and background. The maximum and average pixel values linearly increase with the increasing of background under every lesion diameter and system resolution. The width of the lesion image is independent of the background under every lesion diameter and system resolution. The FWHM of the lesion image is close to the lesion diameter for the lesion which size is larger than system resolution and the difference increases with the system resolution value, it doesn't change with the lesions which size is smaller than system resolution and it is equal to the system resolution.
引用
收藏
相关论文
共 50 条
  • [21] Partial-Volume Effect and a Partial-Volume Correction for the NanoPET/CT™ Preclinical PET/CT Scanner
    Szanda, Istvan
    Livieratos, Lefteris
    Patay, Gergely
    Tsoumpas, Charalampos
    Sunassee, Kavitha
    Mullen, Gregory E.
    Nemeth, Gabor
    Major, Peter
    Marsden, Paul K.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3605 - 3609
  • [22] Automatic Partial Volume Correction in Cardiac PET without Anatomical Images: A Preliminary Study
    Panetta, D.
    Pisani, P.
    Sorace, O.
    Salvadori, P. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S269 - S269
  • [23] Recovery coefficients determination for partial volume effect correction in oncological PET/CT images considering the effect of activity outside the field of view
    Krempser, Alexandre R.
    Ichinose, Roberto M.
    Miranda de Sa, Antonio M. F. L.
    Velasques de Oliveira, Silvia M.
    Carneiro, Michel P.
    ANNALS OF NUCLEAR MEDICINE, 2013, 27 (10) : 924 - 930
  • [24] Recovery coefficients determination for partial volume effect correction in oncological PET/CT images considering the effect of activity outside the field of view
    Alexandre R. Krempser
    Roberto M. Ichinose
    Antonio M. F. L. Miranda de Sá
    Silvia M. Velasques de Oliveira
    Michel P. Carneiro
    Annals of Nuclear Medicine, 2013, 27 : 924 - 930
  • [25] Partial Volume Correction for Lymph Nodes in 18F-PSMA PET Images
    Schaefferkoetter, J.
    Ortega, C.
    Veit-Haibach, P.
    Metser, U.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S776 - S777
  • [26] Subcentimeter Tumor Lesion Delineation for High-Resolution F-18-FDG PET Images: Optimizing Correction for Partial-Volume Effects
    Wallsten, Elin
    Axelsson, Jan
    Sundstrom, Torbjorn
    Riklund, Katrine
    Larsson, Anne
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2013, 41 (02) : 85 - 91
  • [27] Tracer effect on partial volume correction of Brain PET/MR imaging
    Balci, E.
    Akdemir, U.
    Atay, L. O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S20 - S20
  • [28] Importance of correction for the partial volume effect in lung cancer PET studies
    Pournazari, Kamyar
    Jahangiri, Pegah
    Saboury, Babak
    Khosravi, Mohsen
    Al-zaghal, Abdullah
    Torigian, Drew
    Alavi, Abass
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [29] Quantifying the partial volume effect in PET using Benford's law
    Wells, Kevin
    Chiverton, John
    Partridge, Mike
    Barry, Miriam
    Kadhem, Haval
    Ott, Bob
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1616 - 1625
  • [30] An Investigation of Partial Volume Effect and Partial Volume Correction in Small Animal Positron Emission Tomography (PET) of the Rat Brain
    Lehnert, Wencke
    Gregoire, Marie-Claude
    Hu, Xiao
    Meikle, Steven R.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4485 - +