Partial volume effect and its influence factors for sphere lesion PET images

被引:0
|
作者
机构
[1] Chen, Ying-Mao
[2] Geng, Jian-Hua
[3] Tian, Jia-He
[4] Xu, Bai-Xuan
[5] Yao, Shu-Lin
[6] Shao, Ming-Zhe
来源
Chen, Y.-M. | 1600年 / Atomic Energy Press卷 / 48期
关键词
Computer simulation experiment - Influence factor - Lesion diameter - Lesion image - Partial volume effect - Pixel values - Positron emission tomography (PET) - System resolution;
D O I
10.7538/yzk.2014.48.06.1136
中图分类号
学科分类号
摘要
To investigate the partial volume effect (PVE) and its influence factors for sphere lesion positron emission tomography (PET) images and provide the basis for PVE correction, the computer simulation experiments for PET imaging were performed. According to the theory of PVE formation, PET images of the sphere lesions with diameter of 2-30 mm were simulated with computer program in the ratio of background to lesion of 0-0.7 under system resolution of 3-15 mm. The maximum and the average pixel values and the width of the lesion images were calculated. The results show that the maximum and average pixel values increase with the lesion diameter in S shape under every system resolution and background. The maximum and average pixel values decrease in inverse S shape with the increasing of the system resolution under every lesion diameter and background. The maximum and average pixel values linearly increase with the increasing of background under every lesion diameter and system resolution. The width of the lesion image is independent of the background under every lesion diameter and system resolution. The FWHM of the lesion image is close to the lesion diameter for the lesion which size is larger than system resolution and the difference increases with the system resolution value, it doesn't change with the lesions which size is smaller than system resolution and it is equal to the system resolution.
引用
收藏
相关论文
共 50 条
  • [1] A simple method for partial volume effect correction in PET images
    Department of Nuclear Medicine, General Hospital of PLA, Beijing 100853, China
    不详
    Hedianzixue Yu Tance Jishue, 2007, 6 (1231-1238): : 1231 - 1238
  • [2] Correction for partial volume effect in PET blood flow images
    Gage, HD
    Fahey, FH
    Santago, P
    Harkness, BA
    Keyes, JW
    MEDICAL IMAGING 1996: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 1996, 2709 : 244 - 253
  • [3] Measurement of small volumes and the partial volume effect in PET images
    Reiner, B
    Burger, C
    Kunz, G
    Davis, JB
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S128 - S129
  • [4] Correction of partial volume effect of cerebral glucose metabolism images measured by PET/MRI
    Ito, Hiroshi
    Nambu, Takeyuki
    Matsubara, Keisuke
    Kubo, Hitoshi
    Oriuchi, Noboru
    Ishii, Shirou
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [5] A recovery coefficient method for partial volume correction of PET images
    Shyam M. Srinivas
    Thiruvenkatasamy Dhurairaj
    Sandip Basu
    Gonca Bural
    Suleman Surti
    Abass Alavi
    Annals of Nuclear Medicine, 2009, 23 : 341 - 348
  • [6] Reproducibility of radiomics features in partial volume correction of PET images
    Azimi, Mohammad-Saber
    Kamali-Asl, Alireza
    Ay, Mohammad-Reza
    Hosseini, Mahboube Sadat
    Khorshidi, Fatemeh
    Arabi, Hossein
    Rahmim, Arman
    Zaidi, Habib
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [7] A recovery coefficient method for partial volume correction of PET images
    Srinivas, Shyam M.
    Dhurairaj, Thiruvenkatasamy
    Basu, Sandip
    Bural, Gonca
    Surti, Suleman
    Alavi, Abass
    ANNALS OF NUCLEAR MEDICINE, 2009, 23 (04) : 341 - 348
  • [8] PET PARTIAL VOLUME EFFECT INFLUENCE IN MANUAL TARGET VOLUMES DELINEATION IN EXTERNAL RADIOTHERAPY
    Santos, J.
    Dias, A.
    Lencart, J.
    Sousa, O.
    Borges, F.
    Bastos, A.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S435 - S435
  • [9] PET PARTIAL VOLUME EFFECT INFLUENCE IN MANUAL TARGET VOLUMES DELINEATION IN EXTERNAL RADIOTHERAPY
    Santos, J.
    Dias, A.
    Martins, R.
    Carrasco, F.
    Lencart, J.
    Sousa, O.
    Borges, M.
    Torres, C.
    Bastos, A.
    RADIOTHERAPY AND ONCOLOGY, 2010, 94 : S37 - S37
  • [10] MINIMIZING THE PARTIAL VOLUME EFFECT USING THE RESPIRATORY SIGNAL TIMING IN THE ART OF CAPTURING IMAGES OF THE PET CT
    Goulao, Welder Souza
    Werneck Rodrigues, Araken dos Santos
    FIRST LATIN-AMERICAN CONFERENCE ON BIOIMPEDANCE (CLABIO 2012), 2012, 407