Modeling of indoor air treatment of polychlorinated dibenzo-p-dioxins and dibenzofurans using high-efficiency particulate air-carbon filtration

被引:0
|
作者
CH2M Hill, Tempe, AZ, United States [1 ]
不详 [2 ]
不详 [3 ]
不详 [4 ]
不详 [5 ]
机构
来源
J. Air Waste Manage. Assoc. | 2006年 / 8卷 / 1155-1166期
关键词
Carbon - Filters (for fluids) - Mathematical models - Optimization - Particles (particulate matter) - Toxicity;
D O I
暂无
中图分类号
学科分类号
摘要
A high-efficiency particulate air (HEPA)-carbon filtration system was developed by the Access Business Group, LLC, to reduce the indoor levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The HEPA filter removes the particle-bound PCDD/Fs, and the carbon filter removes the gaseous fraction. Because of the toxicity of PCDD/Fs, it is very difficult to handle them in the laboratory. In this study, mathematical modeling was performed to evaluate the performance of the HEPA-carbon filtration system for PCDD/Fs removal and to optimize its design and operation. The model was calibrated with experimental data conducted with toluene in a sealed room. Model simulations with four selected congeners demonstrated that it takes ∼1 hr for the indoor air treatment system to reach the maximum removal efficiency and that the carbon air filter has a life time of 107 yr for dioxin removal. Given a zero emission from the HEPA filter, the overall removal efficiency is 78.7% for 2,3,7,8-tetrachloro dibenzo-p-dioxins, 89.8% for octa-chlorodibenzodioxin, 78% for tetra-chlorodibenzofuran, and 89.8% for octachlorodibenzofuran. The larger the mass emission from the HEPA filter, the lower the overall removal efficiency, and the larger the ratio of the filter flow rate (Qf) to the room flow rate (Q), the higher the overall removal efficiency. When the ratio of Qf/Q is 15, an overall removal efficiency of 90% can be reached for all four of the selected compounds. The removal of the four selected compounds does not change as the relative humidity increases ≤90%. Copyright 2006 Air & Waste Management Association.
引用
收藏
相关论文
共 50 条
  • [21] Study of the diurnal and nocturnal measurement of polychlorinated dibenzo-p-dioxins (CDDs) and polychlorinated dibenzofurans (CDFs) in ambient air.
    Cleverly, DH
    Schweer, G
    Schaum, J
    Winters, D
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U634 - U634
  • [22] Thermal treatment of polychlorinated dibenzo-p-dioxins and dibenzofurans from contaminated soils
    Lee, Wen-Jhy
    Shih, Shun-I
    Chang, Chih-Yuan
    Lai, Yi-Chieh
    Wang, Lin-Chi
    Chang-Chien, Guo-Ping
    JOURNAL OF HAZARDOUS MATERIALS, 2008, 160 (01) : 220 - 227
  • [23] Fate of polychlorinated dibenzo-p-dioxins and dibenzofurans in a fly ash treatment plant
    Li, Hsing-Wang
    Wu, Yee-Lin
    Lee, Wen-Jhy
    Chang-Chien, Guo-Ping
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2007, 57 (09) : 1024 - 1031
  • [24] Polychlorinated dibenzo-p-dioxins and dibenzofurans formed from sucralose at high temperatures
    Shujun Dong
    Guorui Liu
    Jicheng Hu
    Minghui Zheng
    Scientific Reports, 3
  • [25] Polychlorinated dibenzo-p-dioxins and dibenzofurans formed from sucralose at high temperatures
    Dong, Shujun
    Liu, Guorui
    Hu, Jicheng
    Zheng, Minghui
    SCIENTIFIC REPORTS, 2013, 3
  • [26] Occurrence and impact of polychlorinated dibenzo-p-dioxins/dibenzofurans in the air and soil around a municipal solid waste incinerator
    Zhiguang Zhou
    Yue Ren
    Jiazhi Chu
    Nan Li
    Sen Zhen
    Hu Zhao
    Shuang Fan
    Hui Zhang
    Pengjun Xu
    Li Qi
    Shuting Liang
    Bin Zhao
    Journal of Environmental Sciences, 2016, (06) : 244 - 251
  • [28] Comparison of compositions of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in air and soil samples collected in Ishikawa
    Kakimoto, H
    Oka, H
    Harada, Y
    Ushijima, S
    Toriba, A
    Kizu, R
    Hayakawa, K
    JOURNAL OF HEALTH SCIENCE, 2004, 50 (01) : 58 - 65
  • [29] Polychlorinated dibenzofurans and dibenzo-p-dioxins in subsurface soil, superficial dust, and air extracts from a contaminated landfill
    Hansen, LG
    OKeefe, PW
    ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1996, 31 (02) : 271 - 276
  • [30] Size distribution of particle-bound polychlorinated dibenzo-p-dioxins and dibenzofurans in the ambient air of a municipal incinerator
    Chao, MR
    Hu, CW
    Ma, HW
    Chang-Chien, GP
    Lee, WJ
    Chang, LW
    Wu, KY