Modeling of indoor air treatment of polychlorinated dibenzo-p-dioxins and dibenzofurans using high-efficiency particulate air-carbon filtration

被引:0
|
作者
CH2M Hill, Tempe, AZ, United States [1 ]
不详 [2 ]
不详 [3 ]
不详 [4 ]
不详 [5 ]
机构
来源
J. Air Waste Manage. Assoc. | 2006年 / 8卷 / 1155-1166期
关键词
Carbon - Filters (for fluids) - Mathematical models - Optimization - Particles (particulate matter) - Toxicity;
D O I
暂无
中图分类号
学科分类号
摘要
A high-efficiency particulate air (HEPA)-carbon filtration system was developed by the Access Business Group, LLC, to reduce the indoor levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The HEPA filter removes the particle-bound PCDD/Fs, and the carbon filter removes the gaseous fraction. Because of the toxicity of PCDD/Fs, it is very difficult to handle them in the laboratory. In this study, mathematical modeling was performed to evaluate the performance of the HEPA-carbon filtration system for PCDD/Fs removal and to optimize its design and operation. The model was calibrated with experimental data conducted with toluene in a sealed room. Model simulations with four selected congeners demonstrated that it takes ∼1 hr for the indoor air treatment system to reach the maximum removal efficiency and that the carbon air filter has a life time of 107 yr for dioxin removal. Given a zero emission from the HEPA filter, the overall removal efficiency is 78.7% for 2,3,7,8-tetrachloro dibenzo-p-dioxins, 89.8% for octa-chlorodibenzodioxin, 78% for tetra-chlorodibenzofuran, and 89.8% for octachlorodibenzofuran. The larger the mass emission from the HEPA filter, the lower the overall removal efficiency, and the larger the ratio of the filter flow rate (Qf) to the room flow rate (Q), the higher the overall removal efficiency. When the ratio of Qf/Q is 15, an overall removal efficiency of 90% can be reached for all four of the selected compounds. The removal of the four selected compounds does not change as the relative humidity increases ≤90%. Copyright 2006 Air & Waste Management Association.
引用
收藏
相关论文
共 50 条
  • [1] Modeling of indoor air treatment of polychlorinated dibenzo-p-dioxins and dibenzofurans using high-efficiency particulate air-carbon filtration
    Li, Hebi
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2006, 56 (08) : 1155 - 1166
  • [2] INDOOR AIR CONTAMINATION WITH POLYCHLORINATED DIBENZO-P-DIOXINS AND DIBENZOFURANS
    MUKERJEE, D
    PAPKE, O
    KARMAUS, W
    TOXICOLOGY AND INDUSTRIAL HEALTH, 1989, 5 (05) : 731 - 745
  • [3] SURVEY OF POLYCHLORINATED DIBENZO-P-DIOXINS, POLYCHLORINATED DIBENZOFURANS AND POLYCHLORINATED-BIPHENYLS IN URBAN AIR
    SUGITA, K
    ASADA, S
    YOKOCHI, T
    OKAZAWA, T
    ONO, M
    GOTO, S
    CHEMOSPHERE, 1994, 29 (9-11) : 2215 - 2221
  • [4] Levels of polychlorinated dibenzo-p-dioxins and dibenzofurans in dust and air from Lublin
    Duda, Aneta
    Czerwinski, Jacek
    ARCHIVES OF ENVIRONMENTAL PROTECTION, 2008, 34 (03) : 33 - 39
  • [5] LEVELS OF POLYCHLORINATED DIBENZO-P-DIOXINS AND POLYCHLORINATED DIBENZOFURANS IN AMBIENT URBAN AIR IN SYDNEY, AUSTRALIA
    TAUCHER, JA
    BUCKLAND, SJ
    LISTER, AR
    PORTER, LJ
    FERGUSON, C
    CHEMOSPHERE, 1992, 25 (7-10) : 1361 - 1365
  • [6] Monitoring of air pollution by polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans of pine needles in Korea
    Ok, G
    Ji, SH
    Kim, SJ
    Kim, YK
    Park, JH
    Kim, YS
    Han, YH
    CHEMOSPHERE, 2002, 46 (9-10) : 1351 - 1357
  • [7] Dry deposition of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in ambient air
    Shih, ML
    Lee, WS
    Chang-Chien, GP
    Wang, LC
    Hung, CY
    Lin, KC
    CHEMOSPHERE, 2006, 62 (03) : 411 - 416
  • [8] Statistical investigation of polychlorinated dibenzo-p-dioxins and dibenzofurans in the ambient air of Houston, Texas
    Raun, LH
    Correa, O
    Rifai, H
    Suarez, M
    Koenig, L
    CHEMOSPHERE, 2005, 60 (07) : 973 - 989
  • [9] Distribution of polychlorinated dibenzo-p-dioxins and dibenzofurans in ambient air of different regions in China
    Chen, Tong
    Li, Xiaodong
    Yan, Jianhua
    Lu, Shengyong
    Cen, Kefa
    ATMOSPHERIC ENVIRONMENT, 2011, 45 (36) : 6567 - 6575
  • [10] Adsorption of Polychlorinated Dibenzo-p-Dioxins and Dibenzofurans Vapors on Activated Carbon
    Zhou, Xujian
    Li, Xiaodong
    Ma, Xianhua
    Ji, Shasha
    Ni, Mingjiang
    Cen, Kefa
    ENVIRONMENTAL ENGINEERING SCIENCE, 2014, 31 (12) : 664 - 670