National diffuse irradiance standard and its calibration method

被引:0
|
作者
机构
[1] Yang, Yun
[2] Ding, Lei
[3] Quan, Jimei
[4] Bian, Zeqiang
[5] Cheng, Xinghong
[6] Peng, Jida
来源
Yang, Y. (yyaoc@cma.gov.cn) | 1615年 / Science Press卷 / 33期
关键词
Solar radiation;
D O I
暂无
中图分类号
P182 [太阳物理学];
学科分类号
摘要
The standard total irradiance is measured by the standard pyrheliometer and standard diffuse pyranometer. It's very important to establish the diffuse irradiance standard and corresponding calibration method and to transfer the World Radiometric Reference(WRR) from a standard pyheliometer directly to the diffuse irradiance standard, in order to make sure the accuracy of standard pyranometer. By comparing shade/unshade method with sum composition method, the sensitivity using shade/unshade method was not affected by thermal offset, the diffuse irradiance result is more accurate. From the perspective of reducing uncertainty, the shade/unshade method is much better as it just uses one standard instrument with least uncertainty which is directly traceable to WRR, while the error caused by other methods involving more standard instruments was larger.
引用
收藏
相关论文
共 50 条
  • [41] Simple flow system for calibration by the standard addition method
    Koscielniak, P
    Herman, M
    CHEMIA ANALITYCZNA, 1999, 44 (04): : 773 - 784
  • [42] INTERACTIVE CALIBRATION BY A RECURSIVE GENERALIZED STANDARD ADDITION METHOD
    VANDEGINSTE, B
    KLAESSENS, J
    KATEMAN, G
    ANALYTICA CHIMICA ACTA, 1983, 150 (01) : 71 - 86
  • [43] Calibration Method of Standard Scatterer Traceable to MOR Definition
    Niu Zhengjie
    Zhang Jian
    Zhang Guoyu
    Zou Yangyang
    Duan Zongtao
    Zhao Bin
    Yang Junjie
    Ren Taiyang
    Mo Xiaoxu
    Zhang Jianliang
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2023, 50 (10):
  • [44] An external standard method for angular calibration of powder diffractometers
    Wu, WG
    Ruan, YZ
    POWDER DIFFRACTION, 2000, 15 (03) : 173 - 174
  • [45] Stability tests of standard leaks for the calibration by a comparison method
    Arai, Kenta
    Yoshida, Hajime
    Hirata, Masahiro
    Akimichi, Hitoshi
    Kobata, Tokihiko
    MEASUREMENT, 2012, 45 (10) : 2441 - 2444
  • [46] Spectral method for variable temperature standard blackbody calibration
    Liang, P
    INFRARED COMPONENTS AND THEIR APPLICATIONS, 2005, 5640 : 647 - 656
  • [47] SPECTRAL IRRADIANCE STANDARD FOR ULTRAVIOLET
    SAUNDERS, RD
    OTT, WR
    BRIDGES, JM
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1976, 66 (10) : 1097 - 1097
  • [48] Spectral irradiance calibration in the infrared.: XI.: Comparison of α Bootis and 1 Ceres with a laboratory standard
    Witteborn, FC
    Cohen, M
    Bregman, JD
    Wooden, DH
    Heere, K
    Shirley, EL
    ASTRONOMICAL JOURNAL, 1999, 117 (05): : 2552 - 2560
  • [49] STANDARD ADDITION IN HPLC - A CALIBRATION METHOD FOR THE DETERMINATION OF REFERENCE METHOD VALUES
    SCHUMANN, G
    KLAUKE, R
    BUTTNER, J
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 343 (01): : 89 - 90
  • [50] A model-based calibration method for diffuse optical tomography
    Cheng, XF
    Boas, DA
    BIOMEDICAL TOPICAL MEETINGS, TECHNICAL DIGEST, 2000, 38 : 484 - 486