National diffuse irradiance standard and its calibration method

被引:0
|
作者
机构
[1] Yang, Yun
[2] Ding, Lei
[3] Quan, Jimei
[4] Bian, Zeqiang
[5] Cheng, Xinghong
[6] Peng, Jida
来源
Yang, Y. (yyaoc@cma.gov.cn) | 1615年 / Science Press卷 / 33期
关键词
Solar radiation;
D O I
暂无
中图分类号
P182 [太阳物理学];
学科分类号
摘要
The standard total irradiance is measured by the standard pyrheliometer and standard diffuse pyranometer. It's very important to establish the diffuse irradiance standard and corresponding calibration method and to transfer the World Radiometric Reference(WRR) from a standard pyheliometer directly to the diffuse irradiance standard, in order to make sure the accuracy of standard pyranometer. By comparing shade/unshade method with sum composition method, the sensitivity using shade/unshade method was not affected by thermal offset, the diffuse irradiance result is more accurate. From the perspective of reducing uncertainty, the shade/unshade method is much better as it just uses one standard instrument with least uncertainty which is directly traceable to WRR, while the error caused by other methods involving more standard instruments was larger.
引用
收藏
相关论文
共 50 条
  • [31] Calibration of the total irradiance monitor
    Lawrence, GM
    Kopp, G
    Rottman, G
    Harder, J
    Woods, T
    Loui, H
    METROLOGIA, 2003, 40 (01) : S78 - S80
  • [32] Spectral irradiance calibration in the infrared. XVI. Improved accuracy in the infrared spectra of the secondary and tertiary standard calibration stars
    Engelke, Charles W.
    Price, Stephan D.
    Kraemer, Kathleen E.
    ASTRONOMICAL JOURNAL, 2006, 132 (04): : 1445 - 1463
  • [33] Analysis of Measured Irradiance from Experiment of Diffuse Irradiance Shadowing
    Oh, Myeongchan
    Koo, YoungHyun
    Yang, Aran
    Park, Hyeong-Dong
    PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2019 AND THE IEA SHC SOLAR HEATING AND COOLING CONFERENCE FOR BUILDINGS AND INDUSTRY 2019, 2019, : 2068 - 2072
  • [34] DROACOR TOPOGRAPHIC CORRECTION METHOD WITH ADAPTIVE DIFFUSE IRRADIANCE BASED SHADOW CORRECTION
    Schlapfer, Daniel
    Raebsamen, Joel
    Popp, Christoph
    Richter, Rudolf
    Trim, Simon A.
    Vogtli, Marius
    IGARSS 2023 - 2023 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, 2023, : 7332 - 7335
  • [35] Calibration of the Odyssey™ Photosynthetic Irradiance Recorder™ for absolute irradiance measures
    Shaffer, Jared M.
    Beaulieu, Jake J.
    JOURNAL OF FRESHWATER ECOLOGY, 2012, 27 (04) : 599 - 605
  • [36] Realization of National Primary Standard Apparatus of Spectral Irradiance from 200 to 400 nm
    Dai Cai-hong
    Wu Zhi-feng
    Wang Yan-fei
    Li Ling
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39 (08) : 2640 - 2644
  • [37] Standard Method is unsuitable for Detection of diffuse Gastric Cancer
    Di Lellis, Maddalena Angela
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2019, 57 (10): : 1168 - 1168
  • [38] Analytical expressions for estimating sky diffuse irradiance and illuminance on tilted planes for the CIE Standard General Skies
    Torres, Jose Luis
    Garcia, Ignacio
    RENEWABLE ENERGY, 2021, 174 : 320 - 335
  • [39] A calibration method for standard lamps with a line spectrum.
    Ornstein, L. S.
    Burger, H. C.
    ZEITSCHRIFT FUR PHYSIK, 1932, 76 (11-12): : 777 - 779
  • [40] A NEW STANDARD OF SPECTRAL IRRADIANCE
    STAIR, R
    SCHNEIDER, WE
    JACKSON, JK
    APPLIED OPTICS, 1963, 2 (11): : 1151 - 1154