A new method to check the polarity of neutral reactor for 500 kV shunt-reactor

被引:0
|
作者
Zhang, Jing-Wei [1 ]
机构
[1] Shaoguan Power Supply Bureau, Guangdong Power Grid Corporation, Shaoguan 512026, China
关键词
Electric power system protection - Electric reactors;
D O I
暂无
中图分类号
学科分类号
摘要
The polarity of the zero-sequence current differential protection of 500 kV shunt-reactor is not easy to be checked by using the neutral reactor CT winding because there is no current during the normal operation. It may easily lead to misoperation when outside faults happen. This paper presents a method to check the polarity of neutral reactor CT winding. The basic idea is to simulate a single-phase ground by the reactor single-phase operation. There will be a current in the neutral reactor CT winding. The polarity of the zero-sequence protection can be checked by observing the protection's action. Using this method should avoid the impact on the other equipments. Some measures should be taken. The dangerous points in the testing are analyzed and the testing process as well as realative countermeasures is presented. At last, the effectiveness of this method is proved by the on-site testing.
引用
收藏
页码:241 / 243
相关论文
共 50 条
  • [1] TYPE Sh2104 SHUNT-REACTOR PROTECTION CABINET.
    Mogilev, G.P.
    Kozina, N.I
    Ivanova, N.M.
    Berger, P.A.
    Soviet electrical engineering, 1985, 56 (03): : 52 - 55
  • [2] Application of controlled switching to 500-kV shunt reactor current interruption
    Kobayashi, T
    Tsukao, S
    Ohno, L
    Koshizuka, T
    Nishiwaki, S
    Miyake, N
    Matsushita, K
    Saida, T
    IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (02) : 480 - 486
  • [3] Root cause analysis for shunt reactor failure in 500 kV power system
    Arias Velasquez, Ricardo Manuel
    Mejia Lara, Jennifer Vanessa
    ENGINEERING FAILURE ANALYSIS, 2019, 104 : 1157 - 1173
  • [4] Application of controlled switching to 500kV shunt reactor current interruption
    Kobayashi, T
    Tsukao, S
    Ohno, I
    Koshizuka, T
    Nishiwaki, S
    Miyake, N
    Matsushita, K
    Saida, T
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1930 - 1930
  • [5] SHUNT REACTOR SWITCHING TESTS IN BC HYDROS 500-KV SYSTEM
    PEELO, DF
    AVENT, BL
    DRAKOS, JE
    GIUDICI, BC
    IRVINE, JR
    IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1988, 135 (05) : 420 - 434
  • [6] Improving Handling of Shunt-Reactor Effects during Fault with Focus on Protection Devices
    Jezierska, Angelika
    Dzienis, Cezary
    Yelgin, Yilmaz
    Strunz, Kai
    2019 MODERN ELECTRIC POWER SYSTEMS (MEPS), 2019,
  • [7] Analysis of Replacement from Disconnecting Switch to Circuit Breaker for 500 kV Line Shunt Reactor
    Limtrakul, K.
    Premrudeepreechacharn, S.
    Baghzouz, Y.
    2018 18TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2018,
  • [8] SURGES ON A REACTOR AND TRANSFORMER AT 500 KV IN SWITCHING REACTOR BY A VV-500-TYPE CIRCUIT BREAKER
    RASHKES, VS
    GALPERIN.MO
    POPOV, SM
    KOSHTALYUK, R
    IVANOVSKII, A
    KMECH, A
    ELECTRICAL TECHNOLOGY RUSSIA, 1970, 4 : 57 - +
  • [9] Evaluation of Auto-reclose Performance of 500kV Transmission Line with Shunt Reactor in Indonesia
    Kusuma, Aristo Adi
    Pramana, Putu Agus Aditya
    Munir, Buyung Sofiarto
    Tambunan, Handrea Bernando
    PROCEEDINGS OF 2018 THE 10TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND ELECTRICAL ENGINEERING (ICITEE), 2018, : 320 - 324
  • [10] Structure optimal design of 500 kV dry-type air-core shunt reactor based on response surface method
    Zhu, Yanjing
    Kou, Jiajun
    Zhang, Zhiyu
    Liu, Gang
    Hu, Wei
    Xie, Liang
    Zhou, Guangdong
    AIP ADVANCES, 2024, 14 (10)