Experimental analysis of artificial contamination flashover characteristics of long insulator strings on 500 kV transmission lines

被引:0
|
作者
机构
[1] Zhang, Xiuli
[2] Zhang, Qin
[3] 2,Yuan, Tian
[4] Hu, Jianxun
来源
Zhang, X. | 1600年 / Science Press卷 / 39期
关键词
Flashover - Insulator contamination - Salt deposits - Electric lines;
D O I
10.3969/j.issn.1003-6520.2013.12.032
中图分类号
学科分类号
摘要
We experimentally measured the artificial contamination flashover characteristics of 500 kV long insulator strings, since reckoning the flashover voltage of long insulator strings based on data of short insulator strings would result in large deviations. Taking XWP2-160 type two umbrella porcelain insulators as samples, we obtained the artificial contamination flashover voltages of hang single-string insulators under different equivalent salt deposit density (ESDD), different non-soluble deposit density (NSDD), and uneven deposition filthy through experiments. Moreover, we calculated the effective coefficient of creepage distance for this type of insulator string according to the experimental results, and compared the results from tests using string insulators of V type, inverted-V type and single hang type to get the correction coefficient for abnormal types of insulator strings. Experimental results reveal that, the flashover voltage of XWP2-160 insulator string is negatively correlated to ESDD and NSDD; the effective coefficient of creepage distance for the single hang type is 0.78; the flashover voltage of a single insulator from a V type or inverted-V type string is slightly higher than that from the single hang type strings; the string-structure correction coefficients of V type and inverted-V type are 1.08 and 1.15, respectively. The results can be referred by the anti-contamination works for operation of the long insulator strings on 500 kV transmission lines.
引用
收藏
相关论文
共 50 条
  • [21] Analysis of back-flashover lightning- withstanding level of 500-kv-double-circuit transmission lines
    Wu, Shihong
    Wen, Xishan
    Li, Rui
    Xu, Yang
    Lecture Notes in Electrical Engineering, 2015, 334 : 389 - 397
  • [22] Back-flashover resistance level of ±800 kV/500 kV AC-DC hybrid transmission lines
    School of Electrical Engineering, Southwest Jiaotong University, Chengdu
    610031, China
    不详
    610000, China
    不详
    200122, China
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 10 (101-106 and 114):
  • [23] Simulation and experimental analysis of corona loss of 1000 kV and 500 kV AC transmission lines on same tower
    Xie, Xiongjie
    Liu, Qin
    Huo, Feng
    Zhu, Lei
    Liu, Yunpeng
    Zhou, Guoyang
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (03): : 592 - 596
  • [24] Calculation of Voltage Distribution along the Insulator Strings of a 500 kV Transmission Line Based on Finite Element Method
    Ramirez, Juan
    Cabezas, Krissia
    Jimenez, Pedro
    Canelos, Raul
    Escobar, Bolivar
    ENFOQUE UTE, 2020, 11 (03): : 1 - 14
  • [25] Numerical analysis of potential distribution of porcelain insulator strings for 750 kV double-circuit transmission lines on the same tower
    Liu, Yu-Gen
    Tian, Jin-Hu
    Liu, Xiao-Wei
    Cheng, Xi
    Xiao, Lei-Shi
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (07): : 1644 - 1650
  • [26] Experimental Study on Lighting Shielding Performance of ±500 kV HVDC Transmission Lines
    He, Hengxin
    He, Junjia
    Zhang, Dandan
    Ding, Li
    Jiang, Zhenglong
    Wang, Cheng
    Ye, Huisheng
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3421 - +
  • [27] Susceptibility Characteristics of 500 kV Transmission Lines to Forced Outages Caused by Wildfires
    Vaz da Costa, Tito Ricardo
    do Vale, Ailton Teixeira
    Lima, Clarissa Melo
    de Mendonca Brasil, Augusto Cesar
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 209
  • [28] Study on the Influencing Factors of Insulator on the Back-Flashover Lightning Withstand Performance of ±800 kV UHVDC Transmission Lines
    Jiang, Wenbo
    Tang, Chunlin
    Zhou, Bo
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2020, 2020
  • [29] Development of Inspection Tool for Live-line Insulator Strings in 154kV Power Transmission Lines
    Lee, Jae-Kyung
    Park, Joon-Young
    Cho, Byung-Hak
    Oh, Ki-Yong
    EPE: 2009 13TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-9, 2009, : 2110 - 2117
  • [30] Study on pollution flashover characteristic of insulators on 500kV AC transmission lines in high-altitude area
    Huang, Ruiping
    Zhou, Jun
    Xu, Yueneng
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 3306 - 3309