Algorithm for improving the sizing accuracy in real-time bioaerosol single particle mass spectrometer

被引:0
|
作者
Li, Shaoyong [1 ,2 ]
Tang, Lingjun [3 ]
Li, Jingzhen [1 ,2 ]
Su, Zhanming [3 ]
Huang, Zhengxu [1 ,2 ]
Li, Mei [1 ,2 ]
Gao, Wei [1 ,2 ]
Li, Xue [1 ,2 ]
Zhang, Guohua [4 ,5 ]
Li, Lei [1 ,2 ]
机构
[1] Jinan Univ, Inst Mass Spectrometry & Atmospher Environm, Coll Environm & Climate, Guangzhou 510632, Peoples R China
[2] Jinan Univ, Inst Mass Spectrometry & Atmospher Environm, Coll Environm & Climate, Guangdong Prov Engn Res Ctr Online Source Apportio, Guangzhou 510632, Peoples R China
[3] Guangdong MS Inst Sci Instrument Innovat, Guangzhou 510530, Peoples R China
[4] Chinese Acad Sci, Guangzhou Inst Geochem, State Key Lab Organ Geochem, Guangzhou 510640, Peoples R China
[5] Chinese Acad Sci, Guangzhou Inst Geochem, Guangdong Key Lab Environm Protect & Resources Uti, Guangzhou 510640, Peoples R China
关键词
Bioaerosol single particle mass spectrometer; (bio-SPAMS); Particle size measurement; Algorithm; Field programmable gate array (FPGA); AERODYNAMIC LENS; SIZE; PERFORMANCE; INSTRUMENT; EFFICIENCY; DIAMETER; DESIGN;
D O I
10.1016/j.jaerosci.2024.106501
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The newly developed bioaerosol single particle mass spectrometer (Bio-SPAMS) has been innovatively designed for its optical sizing system. The first laser beam in the previous single particle mass spectrometer was split into near distance double beams, similar to the design of APS (Aerodynamic Particle Sizer) and SBS-LIBS (Single Beam Splitting-Laser Induced Breakdown Spectroscopy). All the particles focused by the aerodynamic lens can be sized and got number concentration statistic. However, due to the imperfect beam quality and the large scattering intensity of the large-sized particles, there may be some noise in the scattered signals, particle diameter measured by this sizing system was often larger than actual value if the same trigger threshold was set. In this study, when measuring PSL microspheres with diameters of 1.9, 3.1, and 4.9 mu m, the identification rates of the fixed threshold algorithm were only 75.25%, 55.26%, and 0.27%, respectively. To address such issue, we developed a dynamic threshold waveform recognition algorithm based on field programmable gate array (FPGA), which could process the photoelectric signals collected by a photomultiplier tube (PMT) in real time. The algorithm can dynamically adjust the trigger threshold of the collected scattered signals and accurately calculate the interval time between the near distance double beam. For PSL microspheres with diameters of 1.9, 3.1, and 4.9 mu m, the accuracy of the dynamic threshold algorithm increased by 19.09%, 25.72%, and 88.20%, respectively. This algorithm effectively solves the problem of particle sizing deviation, and improves the particle size measurement accuracy of the bioaerosol mass spectrometer in a wide particle size range from 0.3-6 mu m.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Accuracy of a new real-time continuous glucose monitoring algorithm
    Navas de Solis, M. S.
    AVANCES EN DIABETOLOGIA, 2010, 26 (02): : 129 - 130
  • [32] Real-Time Search Enables a New Gold Standard for TMT Quantitation Accuracy on the Orbitrap Eclipse Tribrid Mass Spectrometer
    Robitaille, Aaron M.
    Huguet, Romain
    Bomgarden, Ryan
    Canterbury, Jesse D.
    Lopez-Ferrer, Daniel
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 7 (29): : 91 - 99
  • [33] ALGORITHMS FOR REAL-TIME DATA ACQUISITION FOR A TIME-OF-FLIGHT MASS-SPECTROMETER
    MATTIE, RP
    HANRAHAN, RJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 194 : 5 - COMP
  • [34] Analytical performance of single particle aerosol mass spectrometer for accurate sizing and isotopic analysis of individual particles
    Su, Yongyang
    Wei, Guanyi
    Wang, Wei
    Xi, Ruiyang
    Wang, Xi
    Xu, Jiang
    Li, Zhiming
    ATMOSPHERIC ENVIRONMENT, 2023, 303
  • [35] Improving a real-time music alignment algorithm for opera performances
    Hoedl, Oliver
    Gubbels, Dennis
    Shabelnyk, Oleksandr
    Reichl, Peter
    2023 4TH INTERNATIONAL SYMPOSIUM ON THE INTERNET OF SOUNDS, 2023, : 341 - 346
  • [36] Real-Time Hardware Design for Improving Laser Detection and Ranging Accuracy
    Brown, Jarrod
    Hughes, Clay
    DeBrunner, Linda
    2012 CONFERENCE RECORD OF THE FORTY SIXTH ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS AND COMPUTERS (ASILOMAR), 2012, : 1115 - 1119
  • [37] Aerodynamic particle sizing versus light scattering intensity measurement as methods for real time particle sizing coupled with time-of-flight mass spectrometry
    Salt, K
    Noble, CA
    Prather, KA
    ANALYTICAL CHEMISTRY, 1996, 68 (01) : 230 - 234
  • [38] A Real-time Single Pulse Detection Algorithm for GPUs
    Adamek, Karel
    Armour, Wesley
    ASTRONOMICAL DATA ANALYSIS SOFTWARE AND SYSTEMS XXVI, 2019, 521 : 596 - 599
  • [39] Real-time detection of individual secondary organic aerosol particle from photooxidation of toluene using aerosol time of flight mass spectrometer
    Wang Zhenya
    Hao Liqing
    Zhou Liuzhu
    Guo Xiaoyong
    Zhao Wenwu
    Fang Li
    Zhang Weijun
    SCIENCE IN CHINA SERIES B-CHEMISTRY, 2006, 49 (03): : 267 - 272