Algorithm for improving the sizing accuracy in real-time bioaerosol single particle mass spectrometer

被引:0
|
作者
Li, Shaoyong [1 ,2 ]
Tang, Lingjun [3 ]
Li, Jingzhen [1 ,2 ]
Su, Zhanming [3 ]
Huang, Zhengxu [1 ,2 ]
Li, Mei [1 ,2 ]
Gao, Wei [1 ,2 ]
Li, Xue [1 ,2 ]
Zhang, Guohua [4 ,5 ]
Li, Lei [1 ,2 ]
机构
[1] Jinan Univ, Inst Mass Spectrometry & Atmospher Environm, Coll Environm & Climate, Guangzhou 510632, Peoples R China
[2] Jinan Univ, Inst Mass Spectrometry & Atmospher Environm, Coll Environm & Climate, Guangdong Prov Engn Res Ctr Online Source Apportio, Guangzhou 510632, Peoples R China
[3] Guangdong MS Inst Sci Instrument Innovat, Guangzhou 510530, Peoples R China
[4] Chinese Acad Sci, Guangzhou Inst Geochem, State Key Lab Organ Geochem, Guangzhou 510640, Peoples R China
[5] Chinese Acad Sci, Guangzhou Inst Geochem, Guangdong Key Lab Environm Protect & Resources Uti, Guangzhou 510640, Peoples R China
关键词
Bioaerosol single particle mass spectrometer; (bio-SPAMS); Particle size measurement; Algorithm; Field programmable gate array (FPGA); AERODYNAMIC LENS; SIZE; PERFORMANCE; INSTRUMENT; EFFICIENCY; DIAMETER; DESIGN;
D O I
10.1016/j.jaerosci.2024.106501
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The newly developed bioaerosol single particle mass spectrometer (Bio-SPAMS) has been innovatively designed for its optical sizing system. The first laser beam in the previous single particle mass spectrometer was split into near distance double beams, similar to the design of APS (Aerodynamic Particle Sizer) and SBS-LIBS (Single Beam Splitting-Laser Induced Breakdown Spectroscopy). All the particles focused by the aerodynamic lens can be sized and got number concentration statistic. However, due to the imperfect beam quality and the large scattering intensity of the large-sized particles, there may be some noise in the scattered signals, particle diameter measured by this sizing system was often larger than actual value if the same trigger threshold was set. In this study, when measuring PSL microspheres with diameters of 1.9, 3.1, and 4.9 mu m, the identification rates of the fixed threshold algorithm were only 75.25%, 55.26%, and 0.27%, respectively. To address such issue, we developed a dynamic threshold waveform recognition algorithm based on field programmable gate array (FPGA), which could process the photoelectric signals collected by a photomultiplier tube (PMT) in real time. The algorithm can dynamically adjust the trigger threshold of the collected scattered signals and accurately calculate the interval time between the near distance double beam. For PSL microspheres with diameters of 1.9, 3.1, and 4.9 mu m, the accuracy of the dynamic threshold algorithm increased by 19.09%, 25.72%, and 88.20%, respectively. This algorithm effectively solves the problem of particle sizing deviation, and improves the particle size measurement accuracy of the bioaerosol mass spectrometer in a wide particle size range from 0.3-6 mu m.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Algorithm improving the CELP coder for real-time communication
    Yu, Sheng Sheng
    Yang, Jie
    Zhou, Jing Li
    CISP 2008: FIRST INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, VOL 2, PROCEEDINGS, 2008, : 565 - 567
  • [22] New Real-Time Resampling Algorithm for Particle Filters
    Bao, Ying
    Chen, Junfeng
    Shi, Zhiguo
    Chen, Kangsheng
    2009 INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATIONS AND SIGNAL PROCESSING (WCSP 2009), 2009, : 776 - 780
  • [23] IMPROVING ACCURACY AND SPEED IN REAL-TIME SIMULATION OF ELECTRIC CIRCUITS
    Howe, R. M.
    INTERNATIONAL JOURNAL OF MODELING SIMULATION AND SCIENTIFIC COMPUTING, 2010, 1 (01) : 47 - 83
  • [24] Development and characterization of an inexpensive single-particle fluorescence spectrometer for bioaerosol monitoring
    Swanson, Benjamin E.
    Huffman, J. Alex
    OPTICS EXPRESS, 2018, 26 (03): : 3646 - 3660
  • [25] Diesel soot mass calculation in real-time with a differential mobility spectrometer
    Symonds, Jonathan P. R.
    Reavell, Kingsley St. J.
    Olfert, Jason S.
    Campbell, Bruce W.
    Swift, Stuart J.
    JOURNAL OF AEROSOL SCIENCE, 2007, 38 (01) : 52 - 68
  • [26] Diesel soot mass calculation in real-time with a differential mobility spectrometer
    Symonds, Jonathan P.R.
    Reavell, Kingsley St.J.
    Olfert, Jason S.
    Campbell, Bruce W.
    Swift, Stuart J.
    1600, Elsevier Ltd (38):
  • [27] Fluorescence preselection of bioaerosol for single-particle mass spectrometry
    Stowers, M. A.
    van Wuijckhuijse, A. L.
    Marijnissen, J. C. M.
    Kientz, Ch. E.
    Ciach, T.
    APPLIED OPTICS, 2006, 45 (33) : 8531 - 8536
  • [28] Single Particle Mass Spectrometry - Bioaerosol Analysis by MALDI MS
    Kleefsman, W. A.
    Stowers, M. A.
    Verheijen, P. J. T.
    Marijnissen, J. C. M.
    KONA POWDER AND PARTICLE JOURNAL, 2008, 26 (205-214) : 205 - 214
  • [29] Quantitative real-time single particle analysis of virions
    Heider, Susanne
    Metzner, Christoph
    VIROLOGY, 2014, 462 : 199 - 206
  • [30] Bioaerosol Identification by Wide Particle Size Range Single Particle Mass Spectrometry
    Li, Xuan
    Li, Lei
    Zhuo, Zeming
    Zhang, Guohua
    Du, Xubing
    Li, Xue
    Huang, Zhengxu
    Zhou, Zhen
    Cheng, Zhi
    ATMOSPHERE, 2023, 14 (06)