Algorithm for improving the sizing accuracy in real-time bioaerosol single particle mass spectrometer

被引:0
|
作者
Li, Shaoyong [1 ,2 ]
Tang, Lingjun [3 ]
Li, Jingzhen [1 ,2 ]
Su, Zhanming [3 ]
Huang, Zhengxu [1 ,2 ]
Li, Mei [1 ,2 ]
Gao, Wei [1 ,2 ]
Li, Xue [1 ,2 ]
Zhang, Guohua [4 ,5 ]
Li, Lei [1 ,2 ]
机构
[1] Jinan Univ, Inst Mass Spectrometry & Atmospher Environm, Coll Environm & Climate, Guangzhou 510632, Peoples R China
[2] Jinan Univ, Inst Mass Spectrometry & Atmospher Environm, Coll Environm & Climate, Guangdong Prov Engn Res Ctr Online Source Apportio, Guangzhou 510632, Peoples R China
[3] Guangdong MS Inst Sci Instrument Innovat, Guangzhou 510530, Peoples R China
[4] Chinese Acad Sci, Guangzhou Inst Geochem, State Key Lab Organ Geochem, Guangzhou 510640, Peoples R China
[5] Chinese Acad Sci, Guangzhou Inst Geochem, Guangdong Key Lab Environm Protect & Resources Uti, Guangzhou 510640, Peoples R China
关键词
Bioaerosol single particle mass spectrometer; (bio-SPAMS); Particle size measurement; Algorithm; Field programmable gate array (FPGA); AERODYNAMIC LENS; SIZE; PERFORMANCE; INSTRUMENT; EFFICIENCY; DIAMETER; DESIGN;
D O I
10.1016/j.jaerosci.2024.106501
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The newly developed bioaerosol single particle mass spectrometer (Bio-SPAMS) has been innovatively designed for its optical sizing system. The first laser beam in the previous single particle mass spectrometer was split into near distance double beams, similar to the design of APS (Aerodynamic Particle Sizer) and SBS-LIBS (Single Beam Splitting-Laser Induced Breakdown Spectroscopy). All the particles focused by the aerodynamic lens can be sized and got number concentration statistic. However, due to the imperfect beam quality and the large scattering intensity of the large-sized particles, there may be some noise in the scattered signals, particle diameter measured by this sizing system was often larger than actual value if the same trigger threshold was set. In this study, when measuring PSL microspheres with diameters of 1.9, 3.1, and 4.9 mu m, the identification rates of the fixed threshold algorithm were only 75.25%, 55.26%, and 0.27%, respectively. To address such issue, we developed a dynamic threshold waveform recognition algorithm based on field programmable gate array (FPGA), which could process the photoelectric signals collected by a photomultiplier tube (PMT) in real time. The algorithm can dynamically adjust the trigger threshold of the collected scattered signals and accurately calculate the interval time between the near distance double beam. For PSL microspheres with diameters of 1.9, 3.1, and 4.9 mu m, the accuracy of the dynamic threshold algorithm increased by 19.09%, 25.72%, and 88.20%, respectively. This algorithm effectively solves the problem of particle sizing deviation, and improves the particle size measurement accuracy of the bioaerosol mass spectrometer in a wide particle size range from 0.3-6 mu m.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Transportable real-time single-particle ion trap mass spectrometer
    Harris, WA
    Reilly, PTA
    Whitten, WB
    Ramsey, JM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (06):
  • [2] An Algorithm for Improving the Accuracy and Real-time of Target Tracking
    Ren, Di
    Xu, Bing
    2018 5TH INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND CONTROL ENGINEERING (ICISCE 2018), 2018, : 112 - 115
  • [3] Design of an enhanced particle sizing time-of-flight mass spectrometer
    Holm, R.L.
    Gälli, M.E.
    Palmer, M.R.
    Quant, F.R.
    Sem, G.J.
    Journal of Aerosol Science, 2000, 31 (SUPPL.1)
  • [4] Source characterization and identification by real-time single particle mass spectrometry
    Reinard, Melissa S.
    Adoua, Kouarne
    Martini, Joseph M.
    Johnston, Murray V.
    ATMOSPHERIC ENVIRONMENT, 2007, 41 (40) : 9397 - 9409
  • [5] AirSentinel®:: A real-time bioaerosol monitor
    Call, C
    Merrill, E
    OPTICALLY BASED BIOLOGICAL AND CHEMICAL SENSING FOR DEFENCE, 2004, 5617 : 53 - 59
  • [6] Bioaerosol analysis by single particle mass spectrometry
    Kleefsman, Ineke
    Stowers, Michael A.
    Verheijen, Peter J. T.
    Van Wuijckhuijse, Arjan L.
    Kientz, Charles E.
    Marijnissen, Jan C. M.
    PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 2007, 24 (02) : 85 - 90
  • [7] Assessment of real-time bioaerosol particle counters using reference chamber experiments
    Lieberherr, Gian
    Auderset, Kevin
    Calpini, Bertrand
    Clot, Bernard
    Crouzy, Benoit
    Gysel-Beer, Martin
    Konzelmann, Thomas
    Manzano, Jose
    Mihajlovic, Andrea
    Moallemi, Alireza
    O'Connor, David
    Sikoparija, Branko
    Sauvageat, Eric
    Tummon, Fiona
    Vasilatou, Konstantina
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2021, 14 (12) : 7693 - 7706
  • [8] DETECTION AND AERODYNAMIC SIZING OF UNSTAINED AEROSOLIZED BACTERIA IN REAL-TIME ON A SINGLE-PARTICLE BASIS
    ADAMS, AJ
    WENNERSTROM, DE
    MAZUMDER, MK
    BIOPHYSICAL JOURNAL, 1984, 45 (02) : A324 - A324
  • [9] Ultrafine nitrate particle events in Baltimore observed by real-time single particle mass spectrometry
    Tolocka, MP
    Lake, DA
    Johnston, MV
    Wexler, AS
    ATMOSPHERIC ENVIRONMENT, 2004, 38 (20) : 3215 - 3223
  • [10] Real-time particle analysis of explosives compounds using single-particle mass spectrometry
    Ruser, Heinrich
    Schade, Julian
    Jeong, Seongho
    Moertel, Max
    Adelhardt, Mario
    Adam, Thomas
    NEXT-GENERATION SPECTROSCOPIC TECHNOLOGIES XVI, 2024, 13026