Increased natural ventilation flow rates through ventilation shafts

被引:0
|
作者
机构
[1] Ray, Stephen D.
[2] Glicksman, Leon R.
来源
| 1600年 / VEETECH Ltd.卷 / 12期
关键词
Airflow network models - Atria - Building simulation - Exhaust openings - Multistorey buildings - Natural ventilation - Physical experiments - Ventilation shafts;
D O I
10.1080/14733315.2013.11684016
中图分类号
学科分类号
摘要
Buoyancy-driven natural ventilation in ventilation shafts is investigated with a small scale physical experiment within a duct and CFD simulations of an office building. For a fixed exhaust opening, smaller shafts lead to higher flow rates in upper floors of a multi-storey building with a shared ventilation shaft. These higher flow rates are caused by increased vertical momentum within the smaller shafts that induce flow through upper floors, an effect referred to as the ejector effect. In the small scale duct, a 0.5 m by 0.5 m shaft leads to a slight reverse flow of 0.0029 m3/s through the upper floor. Holding all other parameters constant and reducing the shaft to 0.25 m by 0.5 m leads to a positive flow rate of 0.012 m3/s through the upper floor. In the CFD simulations of a three storey office building, this same pattern is observed. A 3 m by 2 m shaft leads to a flow rate of 0.0168 m 3/s through the third floor, while the reduced shaft of 2 m by 2 m leads to a flow rate of 0.766 m3/s through the same floor. This increased airflow rate from the ejector effect can allow natural ventilation to be used in buildings where it may otherwise have been deemed inappropriate. Most airflow network models neglect air momentum and fail to account for the ejector effect. To improve these models, an empirical model is incorporated into the airflow network model CoolVent in a manner easily transferable to most airflow network models. © VEETECH Ltd. 2013.
引用
收藏
相关论文
共 50 条
  • [41] Buoyancy Driven Natural Ventilation through Horizontal Openings
    Heiselberg, Per
    Li, Zhigang
    INTERNATIONAL JOURNAL OF VENTILATION, 2009, 8 (03) : 219 - 231
  • [42] Natural Ventilation Around and Through Building: A Numerical Study
    Kaddour, A.
    Bekkouche, S. M. A.
    EXERGY FOR A BETTER ENVIRONMENT AND IMPROVED SUSTAINABILITY 2: APPLICATIONS, 2018, : 533 - 546
  • [43] A comparison of the estimated natural ventilation rates of four solid wall houses with the measured ventilation rates and the implications for low-energy retrofits
    Keig, Peter
    Hyde, Trevor
    McGill, Grainne
    INDOOR AND BUILT ENVIRONMENT, 2016, 25 (01) : 169 - 179
  • [44] Experimental study of air entrainment mode with natural ventilation using shafts in road tunnel fires
    Fan, C. G.
    Ji, J.
    Gao, Z. H.
    Han, J. Y.
    Sun, J. H.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 56 (1-2) : 750 - 757
  • [45] Effects of fire location on the capacity of smoke exhaust from natural ventilation shafts in urban tunnels
    Fan, Chuangang
    Chen, Jian
    Zhou, Yang
    Liu, Xiaoping
    FIRE AND MATERIALS, 2018, 42 (08) : 974 - 984
  • [46] Optimization of design flow rates and component sizing for residential ventilation
    Laverge, J.
    Janssens, A.
    BUILDING AND ENVIRONMENT, 2013, 65 : 81 - 89
  • [47] Vertical temperature distributions in ventilation shafts during a fire
    Chen, Yanqiu
    Zhou, Xiaodong
    Fu, Zhijian
    Zhang, Taolin
    Cao, Bei
    Yang, Lizhong
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2016, 79 : 118 - 125
  • [48] Smoke-free elevator shafts by overpressure ventilation
    Ermer, Horst A.
    Technische Uberwachung, 2006, 47 (03): : 35 - 38
  • [49] Application of Natural Ventilation in Metal Mine Ventilation System
    Zhang, Yongliang
    Tan, Qinglei
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON MECHANICAL SCIENCE AND ENGINEERING, 2016, 66
  • [50] The Boyle System of Ventilation ; and Natural and Artificial Methods of Ventilation
    不详
    JOURNAL OF MENTAL SCIENCE, 1901, 47 (197): : 377 - 377