Consistency Conditions for Cone-Beam CT Data Acquired with a Straight-Line Source Trajectory

被引:11
|
作者
Levine M.S. [1 ]
Sidky E.Y. [1 ]
Pan X. [1 ]
机构
[1] Department of Radiology, University of Chicago, Chicago, IL 60637
基金
美国国家卫生研究院;
关键词
consistency conditions; data redundancy; John's equation;
D O I
10.1016/S1007-0214(10)70009-2
中图分类号
学科分类号
摘要
A consistency condition is developed for computed tomography (CT) projection data acquired from a straight-line X-ray source trajectory. The condition states that integrals of normalized projection data along detector lines parallel to the X-ray path must be equal. The projection data is required to be untruncated only along the detector lines parallel to the X-ray path, a less restrictive requirement compared to Fourier conditions that necessitate completely untruncated data. The condition is implemented numerically on simple image functions, a discretization error bound is estimated, and detection of motion inconsistencies is demonstrated. The results show that the consistency condition may be used to quantitatively compare the quality of projection data sets obtained from different scans of the same image object. © 2010 Tsinghua University Press.
引用
收藏
页码:56 / 61
页数:5
相关论文
共 50 条
  • [31] Simulation studies for triple-source helical cone-beam CT
    Zhao, Jun
    Jin, Yannan
    Jiang, Ming
    Zhuang, Tiange
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [32] Alternative Derivations of M-Line Methods in Cone-Beam CT
    Shi, Daxin
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [33] Dosimetric properties and commissioning of cone-beam CT image beam line with a carbon target
    Dzierma, Y.
    Nuesken, F. G.
    Licht, N. P.
    Ruebe, C.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (07) : 566 - 572
  • [34] A Straight-line Trajectory Tomography Method Based on Multiple Tilted X-ray Cone-beams
    Fu, Jian
    Zhang, Junwei
    Tan, Renbo
    MEASUREMENT TECHNOLOGY AND ITS APPLICATION, PTS 1 AND 2, 2013, 239-240 : 238 - 242
  • [35] Feasibility of improving cone-beam CT number consistency using a scatter correction algorithm
    Li, Jun
    Yao, Weiguang
    Xiao, Ying
    Yu, Yan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (06): : 167 - 176
  • [36] Calculating tumor trajectory and dose-of-the-day using cone-beam CT projections
    Jones, Bernard L.
    Westerly, David
    Miften, Moyed
    MEDICAL PHYSICS, 2015, 42 (02) : 694 - 702
  • [37] A cone-beam reconstruction algorithm based on nutating line filtration for single circular trajectory
    Wang, Yu
    Wang, Feng
    Ou, Zongying
    WCICA 2006: SIXTH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-12, CONFERENCE PROCEEDINGS, 2006, : U11 - U11
  • [38] Direct reconstruction of cone-beam data acquired with a vertex path containing a circle
    Noo, F
    Defrise, M
    Clack, R
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 1998, 7 (06) : 854 - 867
  • [39] Direct reconstruction of cone-beam data acquired with a vertex path containing a circle
    Universite de Liege, Liege, Belgium
    IEEE Trans Image Process, 6 (854-867):
  • [40] FBP reconstruction of cone-beam data acquired with a vertex path containing a circle
    Noo, F
    Defrise, M
    Clack, R
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1698 - 1702