Consistency Conditions for Cone-Beam CT Data Acquired with a Straight-Line Source Trajectory

被引:11
|
作者
Levine M.S. [1 ]
Sidky E.Y. [1 ]
Pan X. [1 ]
机构
[1] Department of Radiology, University of Chicago, Chicago, IL 60637
基金
美国国家卫生研究院;
关键词
consistency conditions; data redundancy; John's equation;
D O I
10.1016/S1007-0214(10)70009-2
中图分类号
学科分类号
摘要
A consistency condition is developed for computed tomography (CT) projection data acquired from a straight-line X-ray source trajectory. The condition states that integrals of normalized projection data along detector lines parallel to the X-ray path must be equal. The projection data is required to be untruncated only along the detector lines parallel to the X-ray path, a less restrictive requirement compared to Fourier conditions that necessitate completely untruncated data. The condition is implemented numerically on simple image functions, a discretization error bound is estimated, and detection of motion inconsistencies is demonstrated. The results show that the consistency condition may be used to quantitatively compare the quality of projection data sets obtained from different scans of the same image object. © 2010 Tsinghua University Press.
引用
收藏
页码:56 / 61
页数:5
相关论文
共 50 条
  • [21] Cone-beam reconstruction for the two-circles-plus-one-line trajectory
    Lu, Yanbin
    Yang, Jiansheng
    Emerson, John W.
    Mao, Heng
    Zhou, Tie
    Si, Yuanzheng
    Jiang, Ming
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (09):
  • [22] Iterative geometric parameter calibration algorithm for the helical trajectory in cone-beam CT
    Han, Yu
    Yan, Bin
    Li, Lei
    Li, Yongli
    Li, Jianxin
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2013, 34 (07): : 1573 - 1580
  • [23] Region-of-interest reconstruction for a cone-beam dental CT with a circular trajectory
    Hu, Zhanli
    Zou, Jing
    Gui, Jianbao
    Zheng, Hairong
    Xia, Dan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 708 : 39 - 45
  • [24] Reconstruction from minimum data in helical cone-beam CT
    Zou, Y
    Pan, XC
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3235 - 3238
  • [25] Accurate Noise Modeling of Cone-Beam CT Projection Data
    Wang, J.
    Xing, L.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [26] Accurate helical cone-beam CT reconstruction with redundant data
    Schoendube, Harald
    Stierstorfer, Karl
    Noo, Frederic
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15): : 4625 - 4644
  • [27] An imperceptible incorrectness in deriving data consistency condition from John's equation for cone-beam CT imaging
    Tang, Shaojie
    Li, Baolei
    Qiao, Zhiwei
    Zhu, Yining
    Guo, Cong
    Wang, Yupeng
    Yuan, Hao
    Yao, Tingwei
    Han, Jingting
    Hu, Yixiong
    Cao, Dong
    Deng, Yu
    Yu, Fuhua
    Shen, Jiandong
    Fan, Jiulun
    OPTIK, 2020, 202 (202):
  • [28] Maximum likelihood reconstruction of circular cone-beam CT data
    Ziegler, Andy
    Koehler, Thomas
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [29] Exact consideration of data redundancies for spiral cone-beam CT
    Lauritsch, G
    Katsevich, A
    Hirsch, M
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 2034 - 2045
  • [30] A reconstruction algorithm for triple-source helical cone-beam CT
    Zhao, Jun
    Jiang, Ming
    Zhuang, Tiange
    Wang, Ge
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1875 - 1878