Consistency Conditions for Cone-Beam CT Data Acquired with a Straight-Line Source Trajectory

被引:11
|
作者
Levine M.S. [1 ]
Sidky E.Y. [1 ]
Pan X. [1 ]
机构
[1] Department of Radiology, University of Chicago, Chicago, IL 60637
基金
美国国家卫生研究院;
关键词
consistency conditions; data redundancy; John's equation;
D O I
10.1016/S1007-0214(10)70009-2
中图分类号
学科分类号
摘要
A consistency condition is developed for computed tomography (CT) projection data acquired from a straight-line X-ray source trajectory. The condition states that integrals of normalized projection data along detector lines parallel to the X-ray path must be equal. The projection data is required to be untruncated only along the detector lines parallel to the X-ray path, a less restrictive requirement compared to Fourier conditions that necessitate completely untruncated data. The condition is implemented numerically on simple image functions, a discretization error bound is estimated, and detection of motion inconsistencies is demonstrated. The results show that the consistency condition may be used to quantitatively compare the quality of projection data sets obtained from different scans of the same image object. © 2010 Tsinghua University Press.
引用
收藏
页码:56 / 61
页数:5
相关论文
共 50 条
  • [1] Consistency Conditions for Cone-Beam CT Data Acquired with a Straight-Line Source Trajectory
    LEVINE Margo S
    SIDKY Emil Y
    TsinghuaScienceandTechnology, 2010, 15 (01) : 56 - 61
  • [2] Data Consistency Conditions for Cone-Beam Projections on a Circular Trajectory
    Clackdoyle, Rolf
    Desbat, Laurent
    Lesaint, Jerome
    Rit, Simon
    IEEE SIGNAL PROCESSING LETTERS, 2016, 23 (12) : 1746 - 1750
  • [3] Cone-Beam Pair-Wise Data Consistency Conditions in Helical CT
    Mouchet, Melanie
    Letang, Jean Michel
    Lesaint, Jerome
    Rit, Simon
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2023, 42 (10) : 2853 - 2864
  • [4] A consistency condition for cone-beam CT with general source trajectories
    Sidky, EY
    Zou, Y
    Xia, D
    Pan, XC
    Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 2042 - 2047
  • [5] Motion compensation for cone-beam CT using Fourier consistency conditions
    Berger, M.
    Xia, Y.
    Aichinger, W.
    Mentl, K.
    Unberath, M.
    Aichert, A.
    Riess, C.
    Hornegger, J.
    Fahrig, R.
    Maier, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (17): : 7181 - 7215
  • [6] Full data consistency conditions for cone-beam projections with sources on a plane
    Clackdoyle, Rolf
    Desbat, Laurent
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (23): : 8437 - 8456
  • [7] Volume image reconstruction from a straight-line source trajectory
    Sidky, Emil Y.
    Zou, Yu
    Pan, Xiaochuan
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2441 - 2444
  • [8] Cone-beam CT for radiation therapy with reverse helical trajectory
    Cho, S.
    Pelizzari, C.
    Pan, X.
    MEDICAL PHYSICS, 2006, 33 (06) : 1984 - 1984
  • [9] Reconstructible volume for cone-beam CT with a reduced saddle trajectory
    Xia, Dan
    Cho, Seungryong
    Pan, Xiaochuan
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2630 - 2632
  • [10] FAN-BEAM RECONSTRUCTION FROM A STRAIGHT-LINE OF SOURCE POINTS
    SMITH, BD
    SINGH, T