Interfacial fracture toughness of synthetic bone-cement interface

被引:0
|
作者
Department of Mechanical and Design Engineering, University of Portsmouth, Anglesea Building, Anglesea Road, Portsmouth PO1 3DJ, United Kingdom [1 ]
机构
来源
Key Eng Mat | 2006年 / 251-256期
关键词
Angle measurement - Bonding - Bone cement - Fracture toughness - Strength of materials - Stress analysis;
D O I
10.4028/0-87849-994-6.251
中图分类号
学科分类号
摘要
Conventionally, the bonding strength of bone-cement interface is obtained by mechanical strength testing which tends to produce large variability between specimens and test methods. In this work, interfacial fracture toughness of synthetic bone-cement interface has been determined using sandwiched Brazilian disk specimens. Experiments were carried out under selected loading angles from 0 to 25 degrees to achieve full loading conditions from mode I to mode II. Solutions for complex stress intensity factors as well as strain energy release rates were obtained for a sandwich disk with a finite interlayer using the finite element method. Phase angles were obtained at a fixed distance to the crack tip. The fracture loads were obtained from the load displacement curves and the values of interfacial fracture toughness were calculated from the fracture loads and the finite element J-integral solutions. The implication of this information on the assessment of fixation in acetabular replacements was discussed in the light of in-vitro fatigue testing of implanted acetabula.
引用
收藏
相关论文
共 50 条
  • [41] Bone-cement interface of the glenoid component:: Stress analysis for varying cement thickness
    Terrier, A
    Büchler, P
    Farron, A
    CLINICAL BIOMECHANICS, 2005, 20 (07) : 710 - 717
  • [42] ACRYLIC BONE-CEMENT
    BAKER, A
    GREENHAM, L
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (05): : 851 - 851
  • [43] Bone-cement interface micromechanical model under cyclic loading
    Sanz-Herrera, J. A.
    Esteban, H.
    Ariza, M. P.
    ADVANCES IN FRACTURE AND DAMAGE MECHANICS X, 2012, 488-489 : 391 - +
  • [44] CEFUROXIME IN BONE-CEMENT
    HUGHES, SPF
    DASH, CH
    ROBERTSON, S
    COX, D
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1981, 63 (02): : 299 - 299
  • [45] MICROSTRUCTURAL PATHWAY OF FRACTURE IN POLY(METHYL METHACRYLATE) BONE-CEMENT
    TOPOLESKI, LDT
    DUCHEYNE, P
    CUCKLER, JM
    BIOMATERIALS, 1993, 14 (15) : 1165 - 1172
  • [46] THE FEMORAL BONE-CEMENT INTERFACE IN TOTAL HIP-REPLACEMENT
    BANNISTER, G
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (05): : 851 - 851
  • [47] NEW ASPECTS OF HIP ALLOARTHROPLASTY - CHANGES AT THE BONE-CEMENT INTERFACE
    BRINKMANN, KE
    MEDIZINISCHE WELT, 1987, 38 (42): : 1367 - 1369
  • [48] A STUDY OF THE BIOACTIVE BONE-CEMENT BONE INTERFACE - QUANTITATIVE AND HISTOLOGICAL-EVALUATION
    NISHIMURA, N
    TAGUCHI, Y
    YAMAMURO, T
    NAKAMURA, T
    KOKUBO, T
    YOSHIHARA, S
    JOURNAL OF APPLIED BIOMATERIALS, 1993, 4 (01) : 29 - 38
  • [49] Bone-cement interfacial behaviour under mixed mode loading conditions
    Wang, J. -Y.
    Tozzi, G.
    Chen, J.
    Contal, F.
    Lupton, C.
    Tong, J.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2010, 3 (05) : 392 - 398
  • [50] Interfacial fracture toughness measurement of a Ti/Si interface
    Modi, M
    Sitaraman, SK
    JOURNAL OF ELECTRONIC PACKAGING, 2004, 126 (03) : 301 - 307