Interfacial fracture toughness of synthetic bone-cement interface

被引:0
|
作者
Department of Mechanical and Design Engineering, University of Portsmouth, Anglesea Building, Anglesea Road, Portsmouth PO1 3DJ, United Kingdom [1 ]
机构
来源
Key Eng Mat | 2006年 / 251-256期
关键词
Angle measurement - Bonding - Bone cement - Fracture toughness - Strength of materials - Stress analysis;
D O I
10.4028/0-87849-994-6.251
中图分类号
学科分类号
摘要
Conventionally, the bonding strength of bone-cement interface is obtained by mechanical strength testing which tends to produce large variability between specimens and test methods. In this work, interfacial fracture toughness of synthetic bone-cement interface has been determined using sandwiched Brazilian disk specimens. Experiments were carried out under selected loading angles from 0 to 25 degrees to achieve full loading conditions from mode I to mode II. Solutions for complex stress intensity factors as well as strain energy release rates were obtained for a sandwich disk with a finite interlayer using the finite element method. Phase angles were obtained at a fixed distance to the crack tip. The fracture loads were obtained from the load displacement curves and the values of interfacial fracture toughness were calculated from the fracture loads and the finite element J-integral solutions. The implication of this information on the assessment of fixation in acetabular replacements was discussed in the light of in-vitro fatigue testing of implanted acetabula.
引用
收藏
相关论文
共 50 条
  • [21] The effect of bone porosity on the shear strength of the bone-cement interface
    Amirfeyz, Rouin
    Bannister, Gordon
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (03) : 843 - 846
  • [22] EFFECT OF FIBERS ON THE FRACTURE STRENGTH OF BONE-CEMENT INTERFACES
    Khandaker, Morshed
    Utsaha, K. C.
    Khadka, Aaush
    Banstola, Sandip
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2013, PT A, 2014,
  • [23] BONE-CEMENT
    SLADE, JM
    ANAESTHESIA, 1989, 44 (02) : 180 - 180
  • [24] STUDIES ON THE LOADABILITY OF THE BONE-CEMENT INTERFACE IN JOINT REPLACEMENT
    GEBAUER, D
    HAGER, H
    BREIER, S
    BIOMEDIZINISCHE TECHNIK, 1983, 28 (09): : 192 - 195
  • [25] EFFECTIVE TECHNIQUE FOR BOND ENHANCEMENT AT BONE-CEMENT INTERFACE
    NARTEN, NC
    LARKE, D
    GREENWALD, AS
    WILDE, AH
    SURGICAL FORUM, 1977, 28 : 505 - 506
  • [26] FRACTURE PROPERTIES OF FULLY CURED ACRYLIC BONE-CEMENT
    HAILEY, JL
    TURNER, IG
    MILES, AW
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1995, 6 (11) : 635 - 638
  • [27] SETTING PROPERTIES OF BONE-CEMENT WITH ADDED SYNTHETIC HYDROXYAPATITE
    CASTALDINI, A
    CAVALLINI, A
    BIOMATERIALS, 1985, 6 (01) : 55 - 60
  • [28] Cement viscosity affects the bone-cement interface in total hip arthroplasty
    Stone, JJS
    Rand, JA
    Chiu, EK
    Grabowski, JJ
    An, KN
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1996, 14 (05) : 834 - 837
  • [29] ANALYTICAL MODELING OF BONE-CEMENT INTERFACE AND FAILURE PREDICTION
    SIH, GC
    MOYER, ET
    BERMAN, AT
    ENGINEERING FRACTURE MECHANICS, 1981, 14 (04) : 779 - 787
  • [30] EFFECT OF GENTAMICIN ON SHEAR AND INTERFACE STRENGTHS OF BONE-CEMENT
    MORAN, JM
    GREENWALD, AS
    MATEJCZYK, MB
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1979, (141) : 96 - 101