In-situ adaptive calibration of incident signal of ultrasonic lubricant film thickness measurements

被引:0
|
作者
Wu, Quanzhong [1 ]
Dou, Pan [1 ,2 ]
Chang, Shiyuan [1 ]
Wu, Tonghai [1 ]
Yu, Min [2 ]
Lei, Yaguo [1 ]
机构
[1] Xi An Jiao Tong Univ, Key Lab Educ, Minist Modern Design & Rotor Bearing Syst, Xian 710049, Shaanxi, Peoples R China
[2] Imperial Coll London, Dept Mech Engn, London SW7 2AZ, England
基金
中国国家自然科学基金;
关键词
Ultrasound; Film thickness; Adaptive calibration; Circle fitting;
D O I
10.1016/j.ymssp.2024.112236
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In ultrasonic reflection measurements of lubricant film thickness, an incident wave is needed as a reference signal and is typically calibrated under controlled ex-situ conditions. However, existing calibration methods have two limitations: 1) significant measurement errors are introduced due to the discrepancy between the calibration environment and the varying operational conditions (for example, temperature), and 2) disassembly of tribo-pairs is necessary. To address these issues, a novel method that enables in-situ adaptive calibration of incident signals is proposed. Particularly, it is found that the variation of the reflected signal against lubricant film thickness can well fit a circle in the polar coordinate, where the desirable incident signals can be extracted using the size and the location of the established circle. Importantly, the circle is iteratively updated to adapt to the variation of the working environment. This novel approach of calibrating incident signals, named the "circle-fitting method", does not require knowledge of the acoustic properties of tribo-pairs and is thus temperature independent. For experimental validation, two test setups of a micrometer-driven calibration rig and a tilting pad thrust bearing platform have been used separately to implement ultrasound measurements of lubricant film thickness, demonstrating accurate results as evidenced by error analysis. Specifically, in the experiment with the micrometer-driven calibration rig, the measurements yielded an amplitude estimation error of 0.2% and a phase estimation error of 0.66%.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Auto-calibration of ultrasonic lubricant-film thickness measurements
    Reddyhoff, T.
    Dwyer-Joyce, R. S.
    Zhang, J.
    Drinkwater, B. W.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (04)
  • [2] High-accuracy incident signal reconstruction for in-situ ultrasonic measurement of oil film thickness
    Dou, Pan
    Jia, Yaping
    Wu, Tonghai
    Peng, Zhongxiao
    Yu, Min
    Reddyhoff, Tom
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2021, 156
  • [3] Calibration of the ultrasonic lubricant-film thickness measurement technique
    Zhang, J
    Drinkwater, BW
    Dwyer-Joyce, RS
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (09) : 1784 - 1791
  • [4] IN-SITU LUBRICATION FILM THICKNESS MEASUREMENTS IN A RADIAL PISTON MOTOR USING ADAPTIVE ULTRASOUND REFLECTOMETRY
    Hansen, Elias V.
    Rendbaek, Jens
    Jensen, Lasse Almind
    Johansen, Per
    PROCEEDINGS OF BATH/ASME 2022 SYMPOSIUM ON FLUID POWER AND MOTION CONTROL, FPMC2022, 2022,
  • [5] Ultrasonic measurement of lubricant film thickness distribution of journal bearing
    Ouyang, Wu
    Zhou, Zhenjiang
    Jin, Yong
    Yan, Xinping
    Liu, Yuanchang
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (06):
  • [6] In-situ nonlinear calibration of a RF signal chain
    Rakuljic, Nevena
    Speir, Carroll
    Otte, Eric
    Bray, Jeff
    Petersen, Corey
    Manganaro, Gabriele
    2018 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2018,
  • [7] ULTRASONIC LIQUID-FILM THICKNESS MEASUREMENTS
    STARKOVICH, VS
    BIRD, PF
    DALLMAN, JC
    STRONG, RD
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1980, 35 (NOV): : 640 - 641
  • [8] In-situ calibration of acoustic measurements of suspended sediment
    Guo Jijie
    Ren inifa
    and Li Yunwu( Institute of Ocean Technology
    ActaOceanologicaSinica, 1999, (04) : 3 - 5
  • [9] CALIBRATION OF GLASS MICROELECTRODES FOR IN-SITU PH MEASUREMENTS
    YANG, J
    BLANCHAR, RW
    HAMMER, RD
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1994, 58 (02) : 354 - 357
  • [10] Ultrasonic measurement for lubricant film thickness with consideration to the effect of the solid materials
    He, Yanbo
    Wang, Jianyun
    Gu, Le
    Zhang, Chuanwei
    Yu, Haide
    Wang, Liqin
    Li, Zhen
    Mao, Yuze
    APPLIED ACOUSTICS, 2023, 211