摘要
The failure rate of converters is higher than any other components in the directly-driven permanent magnet synchronous generator (D-PMSG) based wind power generation systems. Contraposing the changes of the system operating characteristics after converter fault, this paper presents a in-depth study on the operating conditions of converter after an open-circuit fault based on the mathematical model of converters. The studies show that the system is still sustainable after an open-circuit fault of a switch tube, but the operation condition of the converter will be affected and the current waves of the corresponding side will distort. The model of D-PMSG based wind power generation system is developed using MATLAB/Simulink, and the experiment platform for the D-PMSG based wind power generation is given as well. Simulations and experiments are performed under three different types of open-circuit faults. The effects of faults on the system operation characteristics are investigated by the calculation and analysis of some key parameters, such as generator-side current, grid-side current, DC bus voltage, active power output ratio, and total harmonic distortion. The simulation and experimental results show that an open-circuit fault in one converter has little effects on the normal operation of the converter at the other side, but waves of the phase-currents at the corresponding side of fault components will distort. © 2014 State Grid Electric Power Research Institute Press
引用
收藏
页码:23 / 29
相关论文
共 50 条
  • [41] Grid synchronization of grid-side converter in direct drive wind power generation system under grid faults
    Department of Electrical and Information Engineering, Hunan Institute of Engineering, Xiangtan 411101, China
    不详
    Gaodianya Jishu, 2012, 6 (1473-1479):
  • [42] Maximum Power Point Tracking Converter Based on the Open-Circuit Voltage Method for Thermoelectric Generators
    Montecucco, Andrea
    Knox, Andrew R.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (02) : 828 - 839
  • [43] STRATEGY CONTROL CONVERTER TO ENHANCE THE PERFORMANCE IN THE GRID-CONNECTED PMSG WIND POWER GENERATION SYSTEM
    Arrais, Ernano, Jr.
    Nascimento, Franklin H. S.
    Roda, Valentin O.
    Ribeiro, Ricardo L. A.
    Rocha, Thiago O. A.
    Barreto, Rodrigo L.
    Neto, Ceclio M. S.
    2015 IEEE 13TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 1ST SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2015,
  • [44] Open-Circuit Fault Diagnosis of Wind Power Converter Using Variational Mode Decomposition, Trend Feature Analysis and Deep Belief Network
    Zhang, Jingxuan
    Sun, Hexu
    Sun, Zexian
    Dong, Yan
    Dong, Weichao
    APPLIED SCIENCES-BASEL, 2020, 10 (06):
  • [45] An Open-Circuit Faults Diagnosis Method for Matrix Converters based on DWT Analysis of Output Current
    Potamianos, P.
    Mitronikas, E.
    Safacas, A.
    PROCEEDINGS OF THE 2011-14TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE 2011), 2011,
  • [46] Novel Topology and Control Strategy of HVDC Grid Connection for Open Winding PMSG based Wind Power Generation System
    Zeng, Hengli
    Nian, Heng
    2013 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2013, : 196 - 201
  • [48] A Power Decoupling Control for Wind Power Converter Based on Series-Connected MMC and Open-Winding PMSG
    Sun, Baiyan
    Chen, Zhen
    Gao, Congzhe
    Haddad, Abderahmane
    Liang, Jun
    Liu, Xiangdong
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (08) : 8091 - 8101
  • [49] Control and Analysis of Vienna Rectifier Used as the Generator-Side Converter of PMSG-based Wind Power Generation Systems
    Zhao, Hongyan
    Zheng, Trillion Q.
    Li, Yan
    Du, Jifei
    Shi, Pu
    JOURNAL OF POWER ELECTRONICS, 2017, 17 (01) : 212 - 221
  • [50] Robust control based on quantitative feedback theory for PMSG Wind Power Generation System
    Chen Qi
    Meng Tao
    Ji Zhi-cheng
    CCDC 2009: 21ST CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-6, PROCEEDINGS, 2009, : 2122 - 2127