Operational analysis of D-PMSG based wind power generation system under open-circuit converter faults

被引:0
|
作者
Huang, Keyuan [1 ]
Liu, Jingjia [1 ]
Huang, Shoudao [1 ]
Liao, Wu [1 ]
Yi, Yunlan [1 ]
机构
[1] College of Electrical and Information Engineering, Hunan University, Changsha,410082, China
来源
Dianli Xitong Zidonghua/Automation of Electric Power Systems | 2014年 / 14期
关键词
Electric network analysis - MATLAB - Power converters - Failure analysis - Synchronous generators - Permanent magnets - Wind power - Electric power generation;
D O I
10.7500/AEPS20130803004
中图分类号
学科分类号
摘要
The failure rate of converters is higher than any other components in the directly-driven permanent magnet synchronous generator (D-PMSG) based wind power generation systems. Contraposing the changes of the system operating characteristics after converter fault, this paper presents a in-depth study on the operating conditions of converter after an open-circuit fault based on the mathematical model of converters. The studies show that the system is still sustainable after an open-circuit fault of a switch tube, but the operation condition of the converter will be affected and the current waves of the corresponding side will distort. The model of D-PMSG based wind power generation system is developed using MATLAB/Simulink, and the experiment platform for the D-PMSG based wind power generation is given as well. Simulations and experiments are performed under three different types of open-circuit faults. The effects of faults on the system operation characteristics are investigated by the calculation and analysis of some key parameters, such as generator-side current, grid-side current, DC bus voltage, active power output ratio, and total harmonic distortion. The simulation and experimental results show that an open-circuit fault in one converter has little effects on the normal operation of the converter at the other side, but waves of the phase-currents at the corresponding side of fault components will distort. © 2014 State Grid Electric Power Research Institute Press
引用
收藏
页码:23 / 29
相关论文
共 50 条
  • [21] Comparative Study of Converter Topologies used for PMSG Based Wind Power Generation
    Kawale, Yogesh M.
    Dutt, Subroto
    SECOND INTERNATIONAL CONFERENCE ON COMPUTER AND ELECTRICAL ENGINEERING, VOL 2, PROCEEDINGS, 2009, : 367 - +
  • [22] Impedance Modeling Based Method for Sub/Supsynchronous Oscillation Analysis of D-PMSG Wind Farm
    Yuan, Saijun
    Hao, Zhiguo
    Zhang, Tao
    Yuan, Xiaotian
    Shu, Jin
    APPLIED SCIENCES-BASEL, 2019, 9 (14):
  • [23] Characterization and Switch Localization of Three-Phase Interleaved Buck Converter under Open-Circuit Faults
    Gupta, Abhishek Kumar
    Kumar, Mayank
    2022 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS, PEDES, 2022,
  • [24] Fault Diagnosis of Open-circuit Faults in Converters of Direct-driven Permanent Magnet Wind Power Generation Systems Based on Line Voltage Errors
    Hang J.
    Zhang J.
    Cheng M.
    Ding S.
    Li G.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2017, 37 (10): : 2933 - 2943
  • [25] Boost Converter analysis to optimise variable speed PMSG Wind Generation System
    Mesbahi, Abdelouahed
    Saad, Abdellah
    Khafallah, Mohamed
    Bouattane, Omar
    Raihani, Abdelhadi
    PROCEEDINGS OF 2013 INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC), 2013, : 275 - 280
  • [26] Open-Circuit Fault Detection Analysis for Indirect Matrix Converter in Microturbine Generation Systems
    Alexis Andrade-Romero, J.
    Herrera, Victoria
    Romero, J. Franklin A.
    38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 627 - 631
  • [27] Comprehensive Diagnosis of Open-Circuit Fault for Power Devices of Doubly-Fed Wind Power Converter Based on the Features of Voltage and Current
    Li H.
    Yang T.
    Tan H.
    Zhou Z.
    Zheng J.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2021, 36 (16): : 3433 - 3445
  • [28] Fault Detection Method for IGBT Open-circuit Faults in the Modular Multilevel Converter Based on Predictive Model
    Xu, Kunshan
    Xie, Shaojun
    Yan, Ye
    Zhang, Zhao
    Zhang, Binfeng
    Qian, Qiang
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 4190 - 4195
  • [29] Coordinated control of a hybrid wind farm with DFIG-based and PMSG-based wind power generation systems under asymmetrical grid faults
    Yao, Jun
    Pei, Jinxin
    Xu, Depeng
    Liu, Ruikuo
    Wang, Xuewei
    Wang, Caisheng
    Li, Yu
    RENEWABLE ENERGY, 2018, 127 : 613 - 629
  • [30] Short circuit current analysis for DFIG-based wind generation system with Crowbar protection under grid faults
    Zheng, Zhong
    Yang, Geng
    Geng, Hua
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2012, 32 (11): : 7 - 15