Quantifying the Impact of Soil Moisture Sensor Measurements in Determining Green Stormwater Infrastructure Performance

被引:0
|
作者
Shakya, Matina [1 ]
Hess, Amanda [2 ]
Wadzuk, Bridget M. [2 ]
Traver, Robert G. [2 ]
机构
[1] Drexel Univ, Dept Civil Architectural & Environm Engn, 3141 Chestnut St, Philadelphia, PA 19104 USA
[2] Villanova Univ, Dept Civil & Environm Engn, 800 Lancaster Ave, Villanova, PA 19085 USA
关键词
soil moisture calibration; dielectric properties; volumetric water content; uncertainty analysis; subsurface hydrology; CALIBRATION; WATER;
D O I
10.3390/s25010027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The ability to track moisture content using soil moisture sensors in green stormwater infrastructure (GSI) systems allows us to understand the system's water management capacity and recovery. Soil moisture sensors have been used to quantify infiltration and evapotranspiration in GSI practices both preceding, during, and following storm events. Although useful, soil-specific calibration is often needed for soil moisture sensors, as small measurement variations can result in misinterpretation of the water budget and associated GSI performance. The purpose of this research is to quantify the uncertainties that cause discrepancies between default (factory general) sensor soil moisture measurements versus calibrated sensor soil moisture measurements within a subsurface layer of GSI systems. The study uses time domain reflectometry soil moisture sensors based on the ambient soil's dielectric properties under different soil setups in the laboratory and field. The default 'loam' calibration was compared to soil-specific (loamy sand) calibrations developed based on laboratory and GSI field data. The soil-specific calibration equations used a correlation between dielectric properties (real dielectric: epsilon r, and apparent dielectric: Ka) and the volumetric water content from gravimetric samples. A paired t-test was conducted to understand any statistical significance within the datasets. Between laboratory and field calibrations, it was found that field calibration was preferred, as there was less variation in the factory general soil moisture reading compared to gravimetric soil moisture tests. Real dielectric permittivity (epsilon r) and apparent permittivity (Ka) were explored as calibration options and were found to have very similar calibrations, with the largest differences at saturation. The epsilon r produced a 6% difference while the Ka calibration produced a 3% difference in soil moisture measurement at saturation. Ka was chosen over epsilon r as it provided an adequate representation of the soil and is more widely used in soil sensor technology. With the implemented field calibration, the average desaturation time of the GSI was faster by an hour, and the recovery time was quicker by a day. GSI recovery typically takes place within 1-4 days, such that an extension of a day in recovery could result in the conclusion that the system is underperforming, rather than it being the result of a limitation of the soil moisture sensors' default calibrations.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Impact of calibrating a low-cost capacitance-based soil moisture sensor on AquaCrop model performance
    Adla, Soham
    Bruckmaier, Felix
    Arias-Rodriguez, Leonardo F.
    Tripathi, Shivam
    Pande, Saket
    Disse, Markus
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2024, 353
  • [42] Alternative Treatment of Flow Monitoring Data to Evaluate the Impact of Green Infrastructure on Stormwater Volume Reduction in Combined Sewers
    Bloorchian, Azadeh Akhavan
    Zhou, Jianpeng
    World Environmental and Water Resources Congress 2015: Floods, Droughts, and Ecosystems, 2015, : 214 - 220
  • [43] SMART CAPACITIVE MOISTURE SENSOR CALIBRATION IN MINERAL WOOL AND GREEN ROOF SOIL SUBSTRATE
    Kostadinovic, Danka M.
    Jovanovic, Dragana G. Dimitrijevic
    Vucicevic, Biljana S.
    Jovanovic, Marina P.
    Konjikusic, Snezana M.
    THERMAL SCIENCE, 2021, 25 (03): : 1827 - 1836
  • [44] Impact of Soil Particle Size on Soil Moisture Measurements through Dielectric and Electrical Resistance Properties
    Abdelal, Q.
    Al-Kilani, M. R.
    Al-Shishani, G.
    EURASIAN SOIL SCIENCE, 2025, 58 (03)
  • [45] Precipitation and soil moisture data in two engineered urban green infrastructure facilities in New York City
    Alizadehtazi, Bita
    Montalto, Franco A.
    DATA IN BRIEF, 2020, 32
  • [46] Impact of native vegetation and soil moisture dynamics on evapotranspiration in green roof systems
    Dong, Zhaokai
    Bain, Daniel J.
    Paudel, Shishir
    Buck, John K.
    Ng, Carla
    SCIENCE OF THE TOTAL ENVIRONMENT, 2024, 952
  • [47] Impact of Moisture Mobility on Compression Characteristics of MSW Through Soil Structure Measurements
    Shah, M., V
    Brahmbhatt, Abhijit J.
    PROCEEDINGS OF THE 8TH INTERNATIONAL CONGRESS ON ENVIRONMENTAL GEOTECHNICS, VOL 2: TOWARDS A SUSTAINABLE GEOENVIRONMENT, 2019, : 231 - 238
  • [48] Effect of Water Absorbing Polymer Amendment on Performance of Capacitance Soil Moisture Sensor
    Saha, Abhisekh
    Sekharan, Sreedeep
    Manna, Uttam
    ADVANCES IN CIVIL ENGINEERING MATERIALS, 2024, 13 (01): : 116 - 133
  • [49] Predicting the performance of green stormwater infrastructure using multivariate long short-term memory (LSTM) neural network
    Al Mehedi, Md Abdullah
    Amur, Achira
    Metcalf, Jessica
    McGauley, Matthew
    Smith, Virginia
    Wadzuk, Bridget
    JOURNAL OF HYDROLOGY, 2023, 625
  • [50] Assessing the Use of Dual-Drainage Modeling to Determine the Effects of Green Stormwater Infrastructure on Roadway Flooding and Traffic Performance
    Knight, Kathryn L.
    Hou, Guangyang
    Bhaskar, Aditi S.
    Chen, Suren
    WATER, 2021, 13 (11)