Quantifying the Impact of Soil Moisture Sensor Measurements in Determining Green Stormwater Infrastructure Performance

被引:0
|
作者
Shakya, Matina [1 ]
Hess, Amanda [2 ]
Wadzuk, Bridget M. [2 ]
Traver, Robert G. [2 ]
机构
[1] Drexel Univ, Dept Civil Architectural & Environm Engn, 3141 Chestnut St, Philadelphia, PA 19104 USA
[2] Villanova Univ, Dept Civil & Environm Engn, 800 Lancaster Ave, Villanova, PA 19085 USA
关键词
soil moisture calibration; dielectric properties; volumetric water content; uncertainty analysis; subsurface hydrology; CALIBRATION; WATER;
D O I
10.3390/s25010027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The ability to track moisture content using soil moisture sensors in green stormwater infrastructure (GSI) systems allows us to understand the system's water management capacity and recovery. Soil moisture sensors have been used to quantify infiltration and evapotranspiration in GSI practices both preceding, during, and following storm events. Although useful, soil-specific calibration is often needed for soil moisture sensors, as small measurement variations can result in misinterpretation of the water budget and associated GSI performance. The purpose of this research is to quantify the uncertainties that cause discrepancies between default (factory general) sensor soil moisture measurements versus calibrated sensor soil moisture measurements within a subsurface layer of GSI systems. The study uses time domain reflectometry soil moisture sensors based on the ambient soil's dielectric properties under different soil setups in the laboratory and field. The default 'loam' calibration was compared to soil-specific (loamy sand) calibrations developed based on laboratory and GSI field data. The soil-specific calibration equations used a correlation between dielectric properties (real dielectric: epsilon r, and apparent dielectric: Ka) and the volumetric water content from gravimetric samples. A paired t-test was conducted to understand any statistical significance within the datasets. Between laboratory and field calibrations, it was found that field calibration was preferred, as there was less variation in the factory general soil moisture reading compared to gravimetric soil moisture tests. Real dielectric permittivity (epsilon r) and apparent permittivity (Ka) were explored as calibration options and were found to have very similar calibrations, with the largest differences at saturation. The epsilon r produced a 6% difference while the Ka calibration produced a 3% difference in soil moisture measurement at saturation. Ka was chosen over epsilon r as it provided an adequate representation of the soil and is more widely used in soil sensor technology. With the implemented field calibration, the average desaturation time of the GSI was faster by an hour, and the recovery time was quicker by a day. GSI recovery typically takes place within 1-4 days, such that an extension of a day in recovery could result in the conclusion that the system is underperforming, rather than it being the result of a limitation of the soil moisture sensors' default calibrations.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Design and performance of a wireless sensor network for catchment-scale snow and soil moisture measurements
    Kerkez, Branko
    Glaser, Steven D.
    Bales, Roger C.
    Meadows, Matthew W.
    WATER RESOURCES RESEARCH, 2012, 48
  • [22] Impact assessment of green infrastructure and urban growth on stormwater runoff through geospatial modeling
    George, Agnes Liji
    Kumar, Pramod
    Gupta, Kshama
    FRONTIERS IN WATER, 2025, 6
  • [23] Impact of green infrastructure on the mitigation of road-deposited sediment induced stormwater pollution
    Yang, Wenyu
    Wang, Zhenyu
    Hua, Pei
    Zhang, Jin
    Krebs, Peter
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 770
  • [24] Vertical distribution and migration of heavy metals in soil of green stormwater infrastructure receiving roof runoff
    Bao, Junsong
    Chang, Yanhong
    Cheng, Nuo
    Li, Yingxia
    Chang, Xuan
    Feng, Jiashen
    Nan, Xue
    Ren, Hongmin
    SCIENCE OF THE TOTAL ENVIRONMENT, 2024, 954
  • [25] A flexible modeling framework for hydraulic and water quality performance assessment of stormwater green infrastructure
    Massoudieh, Arash
    Maghrebi, Mahdi
    Kamrani, Babak
    Nietch, Christopher
    Tryby, Michael
    Aflaki, Sassan
    Panguluri, Srinivas
    ENVIRONMENTAL MODELLING & SOFTWARE, 2017, 92 : 57 - 73
  • [26] A Combined Sensor for Simultaneous Measurements of Soil Moisture and Electrical Conductivity
    Ma, Daokun
    Li, Daoliang
    Ding, Qisheng
    Wang, Cong
    SENSOR LETTERS, 2013, 11 (6-7) : 1195 - 1198
  • [27] Determining soil moisture by assimilating soil temperature measurements using the Ensemble Kalman Filter
    Dong, Jianzhi
    Steele-Dunne, Susan C.
    Ochsner, Tyson E.
    van de Giesen, Nick
    ADVANCES IN WATER RESOURCES, 2015, 86 : 340 - 353
  • [28] Impact of Youth Education on Green Stormwater Infrastructure Recommendations to Increase Equity and Resilience in Marginalized Communities
    Reckner, Michelle
    Tien, Iris
    Smith, Sarita
    Omunga, Philip
    Alemdar, Meltem
    Hyde, Allen
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2024, 150 (09)
  • [29] Assessing the performance of centralized blue-green infrastructure in dynamic stormwater storage and runoff assignment
    Li, Wei
    Fu, Xin
    Gao, Taolue
    Wang, Xinhao
    URBAN FORESTRY & URBAN GREENING, 2025, 104
  • [30] Laboratory and field measurements with a fiber-optic soil moisture sensor
    Fields, A
    Swain, R
    Kennedy, R
    Belisle, W
    Coleman, T
    Sharma, A
    APPLICATIONS OF PHOTONIC TECHNOLOGY 4: CLOSING THE GAP BETWEEN THEORY, DEVELOPMENT, AND APPLICATION, 2000, 4087 : 1180 - 1187