Full-scale (industrial) wood floor using welded-through dowels

被引:0
|
作者
Bocquet, J.-F. [1 ]
Pizzi, A. [1 ]
Resch, L. [1 ]
机构
[1] ENSTIB-LERMAB, University of Nancy 1, 27 Rue du Merle Blanc, F-88000 Epinal, France
来源
关键词
High-speed dowel rotation welding was used to fabricate a full-scale suspended floor; an applicable civil-engineering structure; to demonstrate that scaling up of such welding technique was feasible. This was coupled with obtaining a more light-weight floor assembly with equal stiffness by maximizing the rigidity of the suspended floor while minimizing the number of timber planks used to build it; and maintaining its vibration frequency high and its level of vibration low. Several assembly and connection combinations of two and three slats linked through welded wood dowels were tried to determine the mechanical resistance of the cross-over joints that had to be used in the building of the floor. Deformation under 4-point static load of the floor was carried out to determine displacement under load and the floor vibration behaviour was determined by the use of accelerometers. The fundamental first natural frequency measured does satisfy well the requirements specified by Eurocode 5. © VSP 2006;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
下载
收藏
页码:1727 / 1739
相关论文
共 50 条
  • [21] Fire test on floor of full-scale steel-framed structure
    Wang, Yong
    Dong, Yuli
    Peng, Puwei
    Li, Shengshen
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2013, 34 (08): : 1 - 11
  • [22] Flexural Behavior of Full-Scale Composite Structural Insulated Floor Panels
    Mousa, Mohammed A.
    Uddin, Nasim
    ADVANCED COMPOSITE MATERIALS, 2011, 20 (06) : 547 - 567
  • [24] Vibration serviceability of suspended floor: Full-scale experimental study and assessment
    Lv, Qingfang
    Lu, Yujie
    Liu, Ye
    STRUCTURES, 2021, 34 : 1651 - 1664
  • [25] Load Testing of Floor Slabs in a Full-scale Reinforced Concrete Building
    Scott, R. H.
    Gilbert, S. G.
    Moss, R. M.
    STRAIN, 2002, 38 (02) : 47 - 54
  • [26] Vertical floor pressures during filling of a full-scale grain bin
    Thompson, SA
    Galili, N
    Williams, RA
    TRANSACTIONS OF THE ASAE, 1996, 39 (03): : 1093 - 1100
  • [27] MODIFIED STUB-GIRDER FLOOR SYSTEM - FULL-SCALE TESTS
    AHMAD, M
    CHIEN, EYL
    HOSAIN, MU
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (11): : 3222 - 3236
  • [28] An experimental study of full-scale open floor plan enclosure fires
    Hidalgo, J. P.
    Cowlard, A.
    Abecassis-Empis, C.
    Maluk, C.
    Majdalani, A. H.
    Kahrrnann, S.
    Hilditch, R.
    Krajcovic, M.
    Torero, J. L.
    FIRE SAFETY JOURNAL, 2017, 89 : 22 - 40
  • [29] Full-scale tests of industrial steel storage pallet racks
    Bernardi, Martina
    Baldassino, Nadia
    Zandonini, Riccardo
    di Gioia, Arturo
    STRUCTURES, 2023, 57
  • [30] Full-scale tests of industrial steel storage pallet racks
    Baldassino, N.
    Bernardi, M.
    Zandonini, R.
    di Gioia, A.
    CURRENT PERSPECTIVES AND NEW DIRECTIONS IN MECHANICS, MODELLING AND DESIGN OF STRUCTURAL SYSTEMS, 2022, : 881 - 886