GEANT4 atomic relaxation data for transfermium nuclei (Z=101-104)

被引:0
|
作者
Chakma, R. [1 ]
Fritzsche, S. [2 ,3 ,4 ]
Hauschild, K. [1 ]
Lopez-Martens, A. [1 ]
机构
[1] Univ Paris Saclay, CNRS-IN2P3, IJCLab, 15 Rue Georges Clemenceau, F-91400 Orsay, France
[2] GSI Helmholtzzentrum Schwerionenforschung, Planckstr 1, D-64291 Darmstadt, Germany
[3] Friedrich Schiller Univ Jena, Theoret Phys Inst, D-07743 Jena, Germany
[4] Helmholtz Inst Jena, Frobelstieg 3, D-07743 Jena, Germany
基金
俄罗斯基础研究基金会;
关键词
GEANT4; Transfermium nuclei; Nuclear structure; Radioactive decays; SPECTROSCOPY; GAMMA; DECAY;
D O I
10.1016/j.nima.2024.170144
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Advanced theoretical methods can accurately calculate various atomic observables and predict electronic structure. Still, systematic computations of the radiative and non-radiative transition probabilities and energies are missing for the actinides and all the transfermium elements. However, these compilations are needed for comprehensive Monte-Carlo simulations (such as GEANT4) of the radioactive decay of transfermium nuclei. These simulations can forma basis for data analysis of experiments, especially with complex detection setups. Investigation of the transfermium nuclei is crucial for understanding the nature of the nuclear force. In this study, simulations based on data from the Jena Atomic Calculator (JAC) and the data from the Evaluated Atomic Data Library (EADL) present in GEANT4 were found compatible for the three elements Ba(Z = 56 ), U(Z = 92 ), and Fm(Z = 100), thus, validating the JAC calculations. For Z> 100, we also found sound agreement between simulations that used data generated with JAC and experimental results involving No(Z = 102) and Rf(Z = 104) isotopes. These results demonstrate that JAC can produce reliable atomic data sets for transfermium elements, which will assist in analyzing nuclear-decay-spectroscopy experiments.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Adaptation of GEANT4 to Monte Carlo dose calculations based on CT data
    Jiang, H
    Paganetti, H
    MEDICAL PHYSICS, 2004, 31 (10) : 2811 - 2818
  • [32] Comparison between Geant4, Fluka and the TileCal test-beam data
    Cascella, M.
    Gallas, M.
    Pokorski, W.
    Ribon, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 74 - 77
  • [33] Comparison of Geant4 transition radiation and ionization loss simulation to testbeam data
    Beischer, B.
    von Doetinchem, P.
    Gast, H.
    Kirn, T.
    Luebelsmeyer, K.
    Orboeck, J.
    Schael, S.
    Siedenburg, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 583 (2-3): : 485 - 493
  • [34] Distributions of positron-emitting nuclei in proton and carbon-ion therapy studied with GEANT4
    Pshenichnov, Igor
    Mishustin, Igor
    Greiner, Walter
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (23): : 6099 - 6112
  • [35] Neutrons from fragmentation of light nuclei in tissue-like media: a study with the GEANT4 toolkit
    Pshenichnov, I
    Mishustin, I
    Greiner, W
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (23): : 5493 - 5507
  • [38] Comparison of Recent Experimental Data with Monte Carlo Tools Such as RoSi, Geant4 and Penelope
    Loehr, Anja
    Durst, Juergen
    Michel, Thilo
    Anton, Gisela
    Geithner, Peter
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3904 - +
  • [39] Study of Dose Enhancement Effects in the Vicinity of High Z Atoms with Geant4 Monte Carlo Simulation
    Huang, Ke
    Yan, Kaiguo
    Yu, Yan
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 1260 - 1264
  • [40] CMS validation experience: Test-beam 2004 data vs Geant4
    Piperov, Stefan
    Hadronic Shower Simulation Workshop, 2007, 896 : 195 - 204