FE analysis of fire-resistance performance of concrete filled steel tubular columns under different loading cases

被引:0
|
作者
Liu, Fa-Qi [1 ]
Yang, Hua [1 ]
机构
[1] School of Civil Engineering, Harbin Institute of Technology, Harbin 150090, China
关键词
Loading - Finite element method - Tubular steel structures - Concretes - Tubes (components) - ABAQUS - Columns (structural);
D O I
暂无
中图分类号
学科分类号
摘要
There are two main loading cases for concrete filled steel tubular (CFST) columns in the real application, i. e. 1) loading applied simultaneously on the core concrete and steel tube, 2) loading only applied on the core concrete, also known as steel tube confined concrete (STCC) columns. With the proper material models under fire loading, ABAQUS finite element program was used to analyze the fire-resistant performance of CFST columns under these two loading cases, accounting for the interaction behavior between steel tube and core concrete. The analysis results indicate that compared with those under the first loading case, the CFST columns under the second loading case exhibit different expansion behavior and fire resistance. Parametric analysis was then conducted to investigate the influence of factors on the fire-resistant performance of STCC columns exposed to ISO-834 standard fire conditions, including load ratio, slenderness ratio, section dimensions, load eccentricity ratio, strength of steel and concrete, etc, conclusions obtained in this paper will provide some reference for the further research.
引用
收藏
页码:201 / 204
相关论文
共 50 条
  • [1] Study on fire-resistance performance of reinforced concrete filled steel tubular columns
    Han, Jinsheng
    Dong, Yuli
    Xu, Zhaodong
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2009, 30 (SUPPL. 2): : 265 - 270
  • [2] Analysis of concrete-filled stainless steel tubular columns under combined fire and loading
    Tan, Q. H.
    Gardner, L.
    Han, L. H.
    Song, D. Y.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 825 - 833
  • [3] Fire resistance of high strength concrete filled steel tubular columns under combined temperature and loading
    Tang, Chao-Wei
    STEEL AND COMPOSITE STRUCTURES, 2018, 27 (02): : 243 - 253
  • [4] Behaviour of concrete filled steel tubular columns under fire
    查晓雄
    钟善桐
    Journal of Harbin Institute of Technology, 2002, (03) : 292 - 296
  • [5] Fire performance of concrete filled stainless steel tubular columns
    Han, Lin-Hai
    Chen, Feng
    Liao, Fei-Yu
    Tao, Zhong
    Uy, Brian
    ENGINEERING STRUCTURES, 2013, 56 : 165 - 181
  • [6] Experimental study on the fire resistance of unprotected concrete-filled steel tubular columns under multi-loading
    Shintani, Yusuke (shintani.yuusuke@takenaka.co.jp), 1600, Elsevier Ltd (120):
  • [7] Experimental study on the fire resistance of unprotected concrete-filled steel tubular columns under multi-loading
    Shintani, Yusuke
    Nishimura, Toshihiko
    Okazaki, Tomohito
    Kinoshita, Takuya
    Ito, Hidetoshi
    Liew, J. Y. Richard
    FIRE SAFETY JOURNAL, 2021, 120
  • [8] Research on fire resistance of recycled concrete filled steel tubular columns
    Luo, Chaoning
    Zha, Xiaoxiong
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 : 35 - 41
  • [9] Performance of Concrete Filled Steel Tubular columns under cyclic and earthquake loading combination
    Xu, JS
    COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 513 - 520
  • [10] Fire resistance analysis of concrete filled double skin steel tubular columns under three-sided fire
    Zhang Y.
    Lv X.
    Liu F.
    Xu Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 : 156 - 162