Thermal response test by improved test rig with heating or cooling soil

被引:0
|
作者
Wencheng, Fu [1 ,2 ]
Jialing, Zhu [1 ,2 ]
Wei, Zhang [1 ,2 ]
机构
[1] Key Laboratory of Efficient Utilization of Low, Medium Grade Energy of Ministry of Education, Tianjin University, Tianjin 300072, China
[2] Tianjin Geothermal Research and Training Center, Tianjin University, Tianjin 300072, China
基金
中国国家自然科学基金;
关键词
Geothermal heat pumps - Heating - Rate constants - Soils - Cooling;
D O I
暂无
中图分类号
学科分类号
摘要
An improved test rig providing both the heat and cold source was used to perform thermal response test (TRT), and the line source model was used for data analysis. The principle of determining the temperature difference between the inlet and outlet of test well can keep the heating or cooling rate constant, along with a reduced size of test rig. Among the influencial factors of the line source model, the temperature difference was determined as the most important, which agreed with the test results. When the gravel was taken as the backfill material, the soil thermal conductivities of heating and cooling at the test place were 1.883 W/(m•K) and 1.754 W/(m•K), respectively, and the deviation of TRT between heating and cooling soil was 6.8%. In the case of fine sand, the thermal conductivities of heating and cooling were 1.541 W/(m•K) and 1.486 W/(m•K), respectively, and the corresponding deviation was 6%. It was also concluded that different velocities of water had less influence on TRT than the temperature difference. © Tianjin University and Springer-Verlag Berlin Heidelberg 2014.
引用
收藏
页码:15 / 20
相关论文
共 50 条
  • [31] FAN SHAPED AND CYLINDRICAL HOLES STUDIED IN A VANE FILM COOLING TEST RIG
    Kinell, Mats
    Utriainen, Esa
    Hylen, Jonas
    Gustavsson, Jonas
    Bradley, Andreas
    Karlsson, Matts
    Wren, Joakim
    PROCEEDINGS OF THE ASME TURBO EXPO 2010, VOL 4, PTS A AND B, 2010, : 1777 - 1784
  • [32] Thermal performance evaluation of an earth-to-air heat exchanger for the heating mode applications using an experimental test rig
    Ahmad, Saif Nawaz
    Prakash, Om
    ARCHIVES OF THERMODYNAMICS, 2022, 43 (01) : 185 - 207
  • [33] IMPROVED TEST RIG DESIGN FOR VIBRATION CONTROL OF A ROTOR BEARING SYSTEM
    Haidl, Peter
    Buchroithner, Armin
    Bader, Michael
    Zisser, Michael
    Schweighofer, Bernhard
    Wegleiter, Hannes
    PROCEEDINGS OF THE 23RD INTERNATIONAL CONGRESS ON SOUND AND VIBRATION: FROM ANCIENT TO MODERN ACOUSTICS, 2016,
  • [34] Decoupling feedback control for improved multivariable vibration test rig tracking
    Vaes, D
    Souverijns, W
    De Cuyper, J
    Swevers, J
    Sas, P
    PROCEEDINGS OF ISMA 2002: INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING, VOLS 1-5, 2002, : 525 - 534
  • [35] Development of a rainfall test rig as an aid in soil block weathering assessment
    Ogunye, FO
    Boussabaine, H
    CONSTRUCTION AND BUILDING MATERIALS, 2002, 16 (03) : 173 - 180
  • [36] Solar Water Heating Thermal Performance Test using an Outdoor Test Method
    Hameer, Sameer
    van Niekerk, Johannes
    2021 IEEE PES/IAS POWERAFRICA CONFERENCE, 2021, : 299 - 302
  • [37] Experimental test of the heating and cooling rate effect on blocking temperatures
    Berndt, Thomas
    Paterson, Greig A.
    Cao, Changqian
    Muxworthy, Adrian R.
    GEOPHYSICAL JOURNAL INTERNATIONAL, 2017, 210 (01) : 255 - 269
  • [38] Oscillatory thermal response test using heating cables: A novel method for in situ thermal property analysis
    Langevin, Hubert
    Giordano, Nicolo
    Raymond, Jasmin
    Gosselin, Louis
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 202
  • [39] Thermal Modeling of the FZG Test Rig: Application to Starved Lubrication Conditions
    Navet, P.
    Changenet, C.
    Ville, F.
    Ghribi, D.
    Cavoret, J.
    TRIBOLOGY TRANSACTIONS, 2020, 63 (06) : 1135 - 1146
  • [40] A TEST RIG FOR TRACTOR GEARBOXES
    JOCHEM, A
    BROWN BOVERI REVIEW, 1985, 72 (05): : 261 - 265