Thermal response test by improved test rig with heating or cooling soil

被引:0
|
作者
Wencheng, Fu [1 ,2 ]
Jialing, Zhu [1 ,2 ]
Wei, Zhang [1 ,2 ]
机构
[1] Key Laboratory of Efficient Utilization of Low, Medium Grade Energy of Ministry of Education, Tianjin University, Tianjin 300072, China
[2] Tianjin Geothermal Research and Training Center, Tianjin University, Tianjin 300072, China
基金
中国国家自然科学基金;
关键词
Geothermal heat pumps - Heating - Rate constants - Soils - Cooling;
D O I
暂无
中图分类号
学科分类号
摘要
An improved test rig providing both the heat and cold source was used to perform thermal response test (TRT), and the line source model was used for data analysis. The principle of determining the temperature difference between the inlet and outlet of test well can keep the heating or cooling rate constant, along with a reduced size of test rig. Among the influencial factors of the line source model, the temperature difference was determined as the most important, which agreed with the test results. When the gravel was taken as the backfill material, the soil thermal conductivities of heating and cooling at the test place were 1.883 W/(m•K) and 1.754 W/(m•K), respectively, and the deviation of TRT between heating and cooling soil was 6.8%. In the case of fine sand, the thermal conductivities of heating and cooling were 1.541 W/(m•K) and 1.486 W/(m•K), respectively, and the corresponding deviation was 6%. It was also concluded that different velocities of water had less influence on TRT than the temperature difference. © Tianjin University and Springer-Verlag Berlin Heidelberg 2014.
引用
收藏
页码:15 / 20
相关论文
共 50 条
  • [21] In-situ heating and cooling of Charpy test specimens
    Manahan, MP
    PENDULUM IMPACT TESTING: A CENTURY OF PROGRESS, 2000, (1380): : 286 - 297
  • [22] Superconductor test rig
    不详
    IEE REVIEW, 1997, 43 (06): : 226 - 226
  • [23] Thermal comfort condition assessment in test buildings with different heating/cooling systems and wall envelopes
    Gendelis, Stanislavs
    Jakovics, Andris
    Ratnieks, Janis
    11TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB2017), 2017, 132 : 153 - 158
  • [24] Study on data processing method for thermal response test of discontinuous heating process
    加热过程间断的热响应试验数据处理方法研究
    Duan, Xinsheng (duanxinsheng@163.com), 2018, Science Press (39):
  • [25] Thermal modelling of a back-to-back gearbox test machine: Application to the FZG test rig
    de Gevigney, J. Durand
    Changenet, C.
    Ville, F.
    Velex, P.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART J-JOURNAL OF ENGINEERING TRIBOLOGY, 2012, 226 (J6) : 501 - 515
  • [26] Thermal grid system and its field test in multiple buildings with individual heating and cooling facility
    Nakao, Masaki
    Nabeshima, Minako
    Kobayashi, Youichi
    Ishinada, Masashi
    16TH INTERNATIONAL SYMPOSIUM ON DISTRICT HEATING AND COOLING, DHC2018, 2018, 149 : 112 - 121
  • [27] Numerical Simulation of Soil Thermal Response Test with Thermal-dissipation Corrected Model
    Ma, Ling
    Gao, Zhiyou
    Wang, Yongzhen
    Sun, Yunchuan
    Zhao, Jun
    Feng, Ning
    LEVERAGING ENERGY TECHNOLOGIES AND POLICY OPTIONS FOR LOW CARBON CITIES, 2017, 143 : 512 - 518
  • [29] Thermal test of blast furnace cooling stave
    Sun, Yu-Fu
    Cui, Jin-He
    Zhao, Jing-Yu
    Yan, Xing-Yi
    Yu, Rong-Bin
    Gao, Ying-Min
    Fan, Fu-Hui
    Zhuzao/Foundry, 2007, 56 (08): : 856 - 859
  • [30] Experimental Study of District Heating Substations in a Hardware-in-the-Loop Test Rig
    Vannahme, Anna
    Busch, Jonas
    Ehrenwirth, Mathias
    Schrag, Tobias
    RESOURCES-BASEL, 2023, 12 (04):